JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 41 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
 
 
National differences  Ireland 
IEC 60065:2001  
(See also Group Differences)            
                                                                
CENELEC / IE  06  I
 
 
 
Equipment fitted with a flexible cable or cord provided with a 13 A plug in 
accordance with Statutory Instrument 525:97 
 
 
 
National differences  Italy 
IEC 60065:2001  
(See also Group Differences)            
                                                                
CENELEC / IT  06  I
 
 
5.1 
Additional markings on the outside of the TV 
receiver in Italian language 
 N/A 
 User 
instructions in Italian language including a 
conformity declaration 
 N/A 
 
Certification number on the back cover 
 
N/A 
 
 
 
 
Page 42 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
 
 National 
differences 
SINGAPORE 
IEC 60065:2001 
NOTE: (These differences are taken from IEC 60065:1993 and adopted to  
IEC 60065:2001) 
 CB / SG  2006  I
 
 
Throughout the standard,
 whenever the words 
"white pine board" appear, insert  the words "or 
plywood board" to it. 
 P 
 
SS143 Amendment No. 1 and No. 2 
 
4.1.3 
(4.1.3)* 
Delete "45 % to 75 % and insert "65 ± 5 %". 
75% maximum in IEC 
60065:2001 
7.1 
(7.1) 
Resistance to heat without external forces. 
Adopt the temperature specified for the tropical 
conditions. 
 P 
8.6 
(9.3.4) 
Delete the note "A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC". 
This is not in IEC 60065:2001 
10.2 
(10.2) 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
 
120h at 93% rel. humidity 
16 
(16) 
External flexible cords 
Delete "IEC Publication 60227: Polyvinyl Chloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC publication 60245: 
Rubber insulated Cables of rated up to and 
including 450/750 V " and insert "Singapore 
Standard 236: Flexible Cords", whenever they 
appear in this clause. 
Delete "CEE Publication 13, CEE Publication 2 
and IEC Publication 60173: Colours of the Cores 
of Flexible Cables and Cords" whenever they 
appear in this clause. 
 P 
16.2 
(16.2) 
Delete the notes in small print and insert "A 
nominal cross-sectional area of  0.75 mm² will 
satisfy this requirement". 
This is not in IEC 60065:2001 
 
Page 43 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
16.3b 
(16.4b) 
Delete “Subclause 3.1 of IEC Publication 60227-2: Part 
2: Test Methods“ and insert “Subclause 9.1 of SS 236“:
9.1 Flexing test (except for tinsel cords, twisted twin 
and single core cords). The test shall be carried out by 
means of the apparatus shown in Figure 5. This 
apparatus has a carrier C supporting two pulleys A and 
B arranged so that the cord is horizontal between the 
pulleys. The carrier moves backward and forward over 
a distance of 1 m at an approximately constant speed 
of 0.33 m/s. 
A sample of flexible cord about 5 m long shall be 
stretched over the pulleys as shown in the figure, each 
end being loaded with a weight. The weight and the 
diameter of the pulleys A and B shall be given in Table 
1. 
Screen cords in accordance with Table 7 shall be 
tested before application of the screen and outer 
sheath. 
The pulleys shall have a semi-circular shaped groove 
for circular cords and a flat groove for parallel twin 
cords. The restraining clamps D shall be fixed so that 
the pull is always applied by the weight from which the 
carrier is moving away. The carrier shall make 30 000 
backward and forward movements (60 000 single 
strokes). Each conductor of the sample shall be loaded 
with the current specified in Table 2. 
For twin cords and for light PVC-sheated 3-core cords, 
the voltage between the conductors shall be 
approximately 230 V a.c. For all other cords having 
three or more cores a three-phase a.c. voltage of about 
400 V shall be applied to three conductors, any 
additional conductors being connected to the neutral. 
During the test no open-circuit in any core or short-
circuit between cores shall occur. 
After the test, any sheath on cords having three or 
more cores shall be removed. The cord, or the laid up 
cores, shall then withstand the voltage test specified in 
Subclause 8.2 or 8.3 as appropriate, but with a test 
voltage not exceeding 2000 V. 
TABLE 1, TABLE 2, FIGURES 4 and  5, see the  
CB BULLETIN
 
 P 
* in parenthesis: clauses acc. to IEC 60065:1993 
 
 
Page 44 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
 National 
differences 
Korea 
IEC 60065:2001  
Information from Korea / KR  06  I I
 
 
 
National supply voltage are 110,220 and 380V 
Rated 220-230V 
 
Only appliances having supply frequency of 
60Hz or a frequency range including 60Hz are 
accepted 
Rated 50-60Hz 
Instruction manuals and marking related safety, 
including name plate shall be in Korean or 
graphical symbols in accordance with IEC 
Publication 417. 
 P 
5.101 Addition 
Other marking; 
Wording “            “ ( See the CB Bulletine) or an 
information regulated in IEC Publication 60417 
giving high voltage warning to layman shall be 
marked, if an apparatus contains a part more 
than 600 volts. 
Tillgång till orden finns för 
närvarande inte ännu 
Access to the wording is for 
the time being not available 
N/A 
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall comply with 
the Korean requirements (KSC 8300 and 8305). 
 P 
31 
Radio frequency Interference 
The apparatus shall comply with the relevant 
CISPR requirements. (EMC=EMI + EMS) 
Not checked 
N/A 
 
 
 