JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate ▷ View online
Page 37 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
Annex B
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151, special
national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Norway, CLASS I equipment which is
intended for connection to the building installation via a
non-industrial plug or a non-industrial appliance
coupler, or both and in addition is intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the network
terminals and ACCESSIBLE parts, have a marking
stating that the equipment must be connected to an
earthed mains socket -outlet.
The marking text shall be as follows:
In the CENELEC countries listed in IEC 62151, special
national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Norway, CLASS I equipment which is
intended for connection to the building installation via a
non-industrial plug or a non-industrial appliance
coupler, or both and in addition is intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the network
terminals and ACCESSIBLE parts, have a marking
stating that the equipment must be connected to an
earthed mains socket -outlet.
The marking text shall be as follows:
"Apparatet skal tilkoples jordet stikkontakt"
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there are
additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text is
identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation forming
part of a component, it shall at least consist of either
- two layers of thin sheet material, each of which shall
pass the electric strength test below, or
- one layer having a distance through insulation of at
least 0.4 mm, which shall pass the electric strength test
below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no distance
through insulation
requirement for the insulation consisting of an
insulating compound completely filling the casing, so
that CLEARANCES
and CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in the
accordance with the
compliance clause below and in addition:
- passes the test and inspection criteria of 13.6 with an
electric strength test of 10.3 using the test voltage of
1.5 kV multiplied by 1,6, and
- is subject to routine testing for electric strength during
manufacturing, using a test voltage of 1.5 kV (for
performance of the test see N.2.1).
It is permitted to bridge this insulation with a capacitor
complying with IEC 60384-14:1993, subclass Y2.
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there are
additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text is
identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation forming
part of a component, it shall at least consist of either
- two layers of thin sheet material, each of which shall
pass the electric strength test below, or
- one layer having a distance through insulation of at
least 0.4 mm, which shall pass the electric strength test
below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no distance
through insulation
requirement for the insulation consisting of an
insulating compound completely filling the casing, so
that CLEARANCES
and CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in the
accordance with the
compliance clause below and in addition:
- passes the test and inspection criteria of 13.6 with an
electric strength test of 10.3 using the test voltage of
1.5 kV multiplied by 1,6, and
- is subject to routine testing for electric strength during
manufacturing, using a test voltage of 1.5 kV (for
performance of the test see N.2.1).
It is permitted to bridge this insulation with a capacitor
complying with IEC 60384-14:1993, subclass Y2.
N/A
Page 38 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
Annex B
Cont.
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the following
conditions:
- the insulation requirements are satisfied by having a
capacitor classified Y3 as defined by IEC 60384-14,
which in addition to the Y3 testing, is tested with an
Impulse test of 2.5kV defined in IEC 62151, subclause
6.2.1;
- the additional testing shall be performed on all the test
specimens as described in IEC 60384-14;
- the Impulse test of 2.5kV is to be performed before
the Endurance Test in IEC 60384-14 in the sequence
of tests as described in IEC 60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE - In Norway, exclusions are applicable for
equipment which is intended for connection to the
building installation
wiring using screw terminals or other reliable means,
and for equipment which is intended for connection to
the building installation wiring via an industrial plug and
14:1993, may bridge this insulation under the following
conditions:
- the insulation requirements are satisfied by having a
capacitor classified Y3 as defined by IEC 60384-14,
which in addition to the Y3 testing, is tested with an
Impulse test of 2.5kV defined in IEC 62151, subclause
6.2.1;
- the additional testing shall be performed on all the test
specimens as described in IEC 60384-14;
- the Impulse test of 2.5kV is to be performed before
the Endurance Test in IEC 60384-14 in the sequence
of tests as described in IEC 60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE - In Norway, exclusions are applicable for
equipment which is intended for connection to the
building installation
wiring using screw terminals or other reliable means,
and for equipment which is intended for connection to
the building installation wiring via an industrial plug and
socket -outlet or an appliance coupler, or both,
complying with IEC 60309 or with a comparable
national standard.
complying with IEC 60309 or with a comparable
national standard.
N/A
Page 39 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
National
differences
Sweden
IEC 60065:2001
(See also Group Differences)
CB Bulletin 110A / SE 06 I
14
Switches containing mercury such as thermostats,
relays and level controllers are not allowed.
relays and level controllers are not allowed.
N/A
Annex B
Replace NOTE 1 by
In the y CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Sweden, CLASS I equipment which is
intended for connection to the building installation via a
non-industrial plug or a non-industrial appliance
coupler, or both and in addition is intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the network
terminals and ACCESSIBLE parts, have a marking
stating that the equipment must be connected to an
earthed mains socket -outlet.
The marking text shall be as follows:
In the y CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Sweden, CLASS I equipment which is
intended for connection to the building installation via a
non-industrial plug or a non-industrial appliance
coupler, or both and in addition is intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the network
terminals and ACCESSIBLE parts, have a marking
stating that the equipment must be connected to an
earthed mains socket -outlet.
The marking text shall be as follows:
"Apparaten skall anslutas till jordat uttag”
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there are additional
requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in Sweden in the
NOTE 1 the following text is added between the first and
second paragraph (this text is identical to the text in EN
60950-1:2001):
If this insulation is solid, including insulation forming part of a
component, it shall at least consist of either
- two layers of thin sheet material, each of which shall pass
the electric strength test below, or
- one layer having a distance through insulation of at least 0.4
mm, which shall pass the electric strength test below.
If this insulation forms part of a semiconductor component
(e.g. an optocoupler), there is no distance through insulation
requirement for the insulation consisting of an insulating
compound completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do not exist, if
the component passes the electric strength test in the
accordance with the
compliance clause below and in addition:
- passes the test and inspection criteria of 13.6 with an electric
strength test of 10.3 using the test voltage of 1.5 kV multiplied
by 1,6 and
- is subject to routine testing for electric strength during
manufacturing, using a test voltage of 1,5 kV (for performance
of the test see N.2.1).
NOTE 1 In Finland, Norway and Sweden, there are additional
requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in Sweden in the
NOTE 1 the following text is added between the first and
second paragraph (this text is identical to the text in EN
60950-1:2001):
If this insulation is solid, including insulation forming part of a
component, it shall at least consist of either
- two layers of thin sheet material, each of which shall pass
the electric strength test below, or
- one layer having a distance through insulation of at least 0.4
mm, which shall pass the electric strength test below.
If this insulation forms part of a semiconductor component
(e.g. an optocoupler), there is no distance through insulation
requirement for the insulation consisting of an insulating
compound completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do not exist, if
the component passes the electric strength test in the
accordance with the
compliance clause below and in addition:
- passes the test and inspection criteria of 13.6 with an electric
strength test of 10.3 using the test voltage of 1.5 kV multiplied
by 1,6 and
- is subject to routine testing for electric strength during
manufacturing, using a test voltage of 1,5 kV (for performance
of the test see N.2.1).
N/A
Page 40 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
Annex B
Cont.
It is permitted to bridge this insulation with a capacitor
complying with IEC 60384-14:1993, subclass Y2. A
capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the following
conditions:
- the insulation requirements are satisfied by having a
capacitor classified Y3 as defined by IEC 60384-14,
which in addition to the Y3 testing, is tested with an
Impulse test of 2.5kV defined in IEC 62151, subclause
6.2.1;
- the additional testing shall be performed on all the test
specimens as described in IEC 60384-14;
- the Impulse test of 2.5kV is to be performed before
the Endurance Test in IEC 60384-14 in the sequence
of tests as described in IEC 60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE - In Sweden, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals or
other reliable means, and for equipment which is
intended for connection to the building installation
wiring via an industrial plug and socket -outlet or an
appliance coupler, or both, complying with IEC 60309
or with a comparable national standard.
complying with IEC 60384-14:1993, subclass Y2. A
capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the following
conditions:
- the insulation requirements are satisfied by having a
capacitor classified Y3 as defined by IEC 60384-14,
which in addition to the Y3 testing, is tested with an
Impulse test of 2.5kV defined in IEC 62151, subclause
6.2.1;
- the additional testing shall be performed on all the test
specimens as described in IEC 60384-14;
- the Impulse test of 2.5kV is to be performed before
the Endurance Test in IEC 60384-14 in the sequence
of tests as described in IEC 60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE - In Sweden, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals or
other reliable means, and for equipment which is
intended for connection to the building installation
wiring via an industrial plug and socket -outlet or an
appliance coupler, or both, complying with IEC 60309
or with a comparable national standard.
N/A