Harman Kardon MAS 100-110 (serv.man2) EMC - CB Certificate ▷ View online
Page 5 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. : Class II apparatus
Pass
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
N/A
5 MARKING
Comprehensible and easily discernible
Pass
Permanent durability against water and petroleum
spirit
spirit
After this test, the marking is
legible; it is not easily possible
to remove the marking plate
and show no curling.
legible; it is not easily possible
to remove the marking plate
and show no curling.
Pass
5.1 Identification,
maker,
model ................................... : MAS100, MAS110
Pass
Class II symbol if applicable
On rear enclosure
Pass
Rated supply voltage and symbol .......................... : See marking plate
Pass
Frequency if safety dependant
See marking plate
Pass
Rated current or power consumption .................... : See marking plate
Pass
5.2
Earth terminal
Class II equipment
N/A
Hazardous live terminals
No Hazardous live terminal
N/A
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
On circuit diagram.
Pass
5.4
Instructions for use
Pass
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
Adequate instructions
provided.
provided.
Pass
Hazardous live terminals, instructions for wiring
No hazardous live terminal
N/A
Instructions for replacing lithium battery
No lithium battery
N/A
Instructions for modem if fitted
No modem used.
N/A
Class I earth connection warning
N/A
Instructions for multimedia system connection
Adequate instructions
provided.
provided.
Pass
Special stability warning for fixed installation
Not such equipment
N/A
Page 6 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
The appliance coupler is acting
as disconnect device. The
manual has suitable statement.
as disconnect device. The
manual has suitable statement.
Pass
Instructions for permanently connected equipment Not permanently connected
equipment.
N/A
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation.
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : Class 1 Laser
Pass
Emission limits under fault conditions .................... : Class 1 Laser
Pass
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
Pass
7.1.1
Temperature rise of accessible parts
(see appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
Pass
7.1.4
Temperature rise of windings
(see appended table)
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
(see appended table)
Pass
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Windings and PCB are
covered by lacquer and
considered to be bare.
covered by lacquer and
considered to be bare.
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools required.
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
Pass
Page 7 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by hand.
N/A
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Pass
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Pass
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Resistant: R54
Transformer T4 and T5
Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
Y2 capacitor: C2, C3
X2 capacitor: C1, C5, C4, C13
Pass
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
No such capacitor
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
Y2 capacitor: C43, C42
Pass
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
N/A
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
N/A
Separation by Class II isolating transformer
N/A
Separation by Class I transformer
N/A
Separation by earthed conductive part
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) : No such insulation used.
N/A
Reinforced insulation > 0,4 mm (mm) .................... : Bobbin of transformer T4: Min.
1.0mm
Bobbin of transformer T5: Min.
1.0mm
Bobbin of transformer T5: Min.
1.0mm
Pass
Thin sheet insulation
Pass
Page 8 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
Two layers of insulating tape
provided between primary
winding and secondary
winding of transformer, each
layer comply with the
requirement of 10.3.
provided between primary
winding and secondary
winding of transformer, each
layer comply with the
requirement of 10.3.
Pass
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Primary wiring: min. 0.4mm
Pass
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Pass
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Pass
8.11
Detaching of wires
Pass
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
All wires are fixed by double
securement.
securement.
Pass
Vibration
test carried out ........................................ : No, no need.
N/A
8.12 Void
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Fastened by metal screws.
Pass
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
The internal lead wires are
secured away from the hot
parts and sharp edges by the
construction.
secured away from the hot
parts and sharp edges by the
construction.
Pass
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
See below.
Pass
8.19.1 Disconnect
device
Appliance coupler is used as
the disconnect device.
the disconnect device.
Pass