                                                                      Page 5 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus ................................. : Class II apparatus 
Pass 
 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 Ventilation 
instructions 
require the use of the test 
box 
 N/A 
 
 
5 MARKING 
 
 
Comprehensible and easily discernible 
 
Pass 
 
Permanent durability against water and petroleum 
spirit 
After this test, the marking is 
legible; it is not easily possible 
to remove the marking plate 
and show no curling. 
Pass 
5.1 Identification, 
maker, 
model ................................... : MAS100, MAS110 
Pass 
 
Class II symbol if applicable 
On rear enclosure 
Pass 
 
Rated supply voltage and symbol .......................... : See marking plate 
Pass 
 
Frequency if safety dependant 
See marking plate 
Pass 
 
Rated current or power consumption .................... : See marking plate 
Pass 
5.2 
Earth terminal 
Class II equipment 
N/A 
 
Hazardous live terminals 
No Hazardous live terminal 
N/A 
 
Supply output terminals (other than mains) 
 
N/A 
5.3 
Use of triangle with exclamation mark 
On circuit diagram. 
Pass 
5.4 
Instructions for use 
 
Pass 
5.4.1 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled 
with liquid, etc. 
Adequate instructions 
provided. 
Pass 
 
Hazardous live terminals, instructions for wiring 
No hazardous live terminal 
N/A 
 
Instructions for replacing lithium battery 
No lithium battery 
N/A 
 
Instructions for modem if fitted 
No modem used. 
N/A 
 
Class I earth connection warning 
 
N/A 
 
Instructions for multimedia system connection 
Adequate instructions 
provided. 
Pass 
 
Special stability warning for fixed installation 
Not such equipment 
N/A 
 
                                                                      Page 6 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
The appliance coupler is acting 
as disconnect device. The 
manual has suitable statement. 
Pass 
 
Instructions for permanently connected equipment Not permanently connected 
equipment.  
N/A 
 
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No ionizing radiation. 
N/A 
6.1 
EN 60065 
European Council Directive 96/29/Euratom of 13 
May 1996 10cm from outer surface of apparatus 
<1µSv/h (0,1mR/h) 
 N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  .... : Class 1 Laser 
Pass 
 
Emission limits under fault conditions .................... : Class 1 Laser 
Pass 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
(see appended table) 
Pass 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
Pass 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
Pass 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table) 
Pass 
7.1.4 
Temperature rise of windings 
(see appended table) 
Pass 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
Pass 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
(see appended table) 
Pass 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Windings and PCB are 
covered by lacquer and 
considered to be bare. 
Pass 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Tools required. 
Pass 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
 Pass 
 
                                                                      Page 7 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No cover removable by hand. 
N/A 
8.5 
Class I equipment 
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
 N/A 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
 Pass 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
 Pass 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Resistant: R54  
Transformer T4 and T5  
Pass 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
Y2 capacitor: C2, C3 
X2 capacitor: C1, C5, C4, C13 
Pass 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
No such capacitor 
N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
Y2 capacitor: C43, C42 
 
Pass 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
 N/A 
 
Reinforced or double insulation between circuits 
operating at voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 120 V d.c. and 
hazardous live parts at higher voltage 
 N/A 
 
Separation by Class II isolating transformer 
 
N/A 
 
Separation by Class I transformer 
 
N/A 
 
Separation by earthed conductive part 
 
N/A 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : No such insulation used. 
N/A 
 
Reinforced insulation > 0,4 mm (mm) .................... : Bobbin  of transformer T4: Min. 
1.0mm  
Bobbin  of transformer T5: Min. 
1.0mm 
Pass 
 
Thin sheet insulation 
 
Pass 
 
                                                                      Page 8 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
Two layers of insulating tape 
provided between primary 
winding and secondary 
winding of transformer, each 
layer comply with the 
requirement of 10.3. 
Pass 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 N/A 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Primary wiring: min. 0.4mm 
Pass 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
 Pass 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
 Pass 
8.11 
Detaching of wires 
 
Pass 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
All wires are fixed by double 
securement. 
Pass 
 Vibration 
test carried out  ........................................ : No, no need. 
N/A 
8.12 Void 
 
 
N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 N/A 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
Fastened by metal screws. 
Pass 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
The internal lead wires are 
secured away from the hot 
parts and sharp edges by the 
construction. 
Pass 
8.16 
Only special supply equipment can be used 
 
N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
See below. 
Pass 
8.19.1 Disconnect 
device 
Appliance coupler is used as 
the disconnect device. 
Pass 