Harman Kardon MAS 100-110 (serv.man2) EMC - CB Certificate ▷ View online
Page 13 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Inductor: T1, T2, T3
Transformer: T4, T5
Dongguan City Dazhong
Electronic Co., Ltd.
T1, T2 type: SG08210
T3 type: SG08049
T4 type: SG08050
T5 type: SG08048
Transformer: T4, T5
Dongguan City Dazhong
Electronic Co., Ltd.
T1, T2 type: SG08210
T3 type: SG08049
T4 type: SG08050
T5 type: SG08048
Pass
Transformers and inductors separately approved . : No
N/A
14.3.2 General
Pass
14.3.3 Constructional
requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(See table 13.3& 13.4)
Pass
14.3.3.2
Transformers meet the constructional
requirements
requirements
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Pass
Coil formers and partition walls > 0,4 mm
Transformer bobbin thickness
at least 1.0mm.
at least 1.0mm.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Pass
Coil formers and partition walls > 0,4 mm
Transformer bobbin thickness
at least 1.0mm.
at least 1.0mm.
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high-voltage component.
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
Page 14 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
See below
Pass
Protective devices used within their ratings
Fuse FH1: T5AL 250V
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
(see appended table)
Pass
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Pass
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : Fuse FH1: T5AL 250V
Pass
14.5.2.3
Not possible to connect fuses in parallel ............... : The fuse holder is so designed
that fuse-links can not be
connected in parallel.
connected in parallel.
Pass
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
The fuse holder is so designed
that not possible to touch
hazardous live parts when
replacing fuse-links without the
use of a tool.
that not possible to touch
hazardous live parts when
replacing fuse-links without the
use of a tool.
Pass
14.5.3
PTC-S thermistors comply with IEC 60730-1
No PTC used.
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
No switch used.
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
N/A
Page 15 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
No safety interlock.
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
No such device.
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9
Motors
Secondary DC motor.
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N/A
14.10
Batteries
No such device within the EUT.
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N/A
Page 16 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
IC6, IC7, IC8
Pass
Optocouplers comply with Cl. 8
Pass
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
Pass
14.12
Surge suppression varistors
Pass
Comply with IEC 61051-2
Pass
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
Pass
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
Pass
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Mains plug and appliance inlet
are approved.
are approved.
Pass
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
Pass
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No such outlet.
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
N/A
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
output voltage: output circuit not connected to
earth
N/A