                                                                      Page 13 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type .............................. :
Inductor: T1, T2, T3 
Transformer: T4, T5  
Dongguan  City   Dazhong   
Electronic Co., Ltd. 
T1, T2 type: SG08210 
T3 type: SG08049 
T4 type: SG08050 
T5 type: SG08048 
Pass 
 
Transformers and inductors separately approved . : No  
N/A 
14.3.2 General 
 
Pass 
14.3.3 Constructional 
requirements 
 
Pass 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(See table 13.3& 13.4) 
Pass 
14.3.3.2 
Transformers meet the constructional 
requirements 
 Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
 Pass 
 
Coil formers and partition walls > 0,4 mm 
Transformer bobbin thickness 
at least 1.0mm. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
 Pass 
 
Coil formers and partition walls > 0,4 mm 
Transformer bobbin thickness 
at least 1.0mm. 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
N/A 
14.4 
High voltage components 
No high-voltage component. 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
 
                                                                      Page 14 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 
Protective devices 
See below 
Pass 
 
Protective devices used within their ratings 
Fuse FH1: T5AL 250V 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
(see appended table) 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 N/A 
14.5.1.2 
a) Thermal links separately approved 
 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
 Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : Fuse FH1: T5AL 250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel ............... : The fuse holder is so designed 
that fuse-links can not be 
connected in parallel. 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
The fuse holder is so designed 
that not possible to touch 
hazardous live parts when 
replacing fuse-links without the 
use of a tool. 
Pass 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No PTC used. 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 N/A 
14.6 
Switches 
No switch used. 
N/A 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
 
N/A 
 
                                                                      Page 15 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
 N/A 
 
Socket outlet current marking correct 
 
N/A 
14.7 
Safety interlocks 
No safety interlock. 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
 
N/A 
14.8 
Voltage setting devices 
No such device. 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
 N/A 
14.9 
Motors 
Secondary DC motor. 
N/A 
14.9.1 
Endurance test on motors 
 
N/A 
 
Motor start test 
 
N/A 
 
Dielectric strength test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
14.9.3 
Protection against moving parts 
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
 N/A 
14.10 
Batteries 
No such device within the EUT. 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 N/A 
 
                                                                      Page 16 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 N/A 
14.10.3 
Recharging currents and times within 
manufacturers limits 
 N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 N/A 
14.10.4 
Battery mould stress relief 
 
N/A 
14.10.5 
Battery drop test 
 
N/A 
14.11 
Optocouplers 
IC6, IC7, IC8 
Pass 
 
Optocouplers comply with Cl. 8 
 
Pass 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
 
Pass 
14.12 
Surge suppression varistors 
 
Pass 
 
Comply with IEC 61051-2 
 
Pass 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
 
Pass 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 Pass 
 
 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
Mains plug and appliance inlet 
are approved. 
Pass 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
 
No risk of insertion in mains socket-outlets 
 
Pass 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
No such outlet. 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets 
 N/A 
15.2 
Provision for protective earthing 
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
 
N/A 
 
Class I supply equipment with non-hazardous live 
output voltage: output circuit not connected to 
earth 
 N/A 