Harman Kardon MAS 100-110 (serv.man2) EMC - CB Certificate ▷ View online

 
                                                                      Page 33 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
 
7.1 
TABLE: temperature rise measurements  
Pass 
 
Power consumption in the OFF/Stand-by Stand-by: 
1.0W 
— 
 
Position of the functional switch (W) ...................... : -- 
— 
 
Operating conditions 
Normal operation. Pink noise as input. 4h operation until stable. 
Un (V) 
In (A)  
Pn (W)  
Pout (V / mA) 
264 0.231 
50.1 
8.75 
240 0.242 
50.2 
8.75 
100 0.513 
50.7 
8.75 
90 0.572 
51.1 
8.75 
         
  Loudspeaker impedance (Ω) ................................. : 6Ω 
— 
         
  Several loudspeaker systems 
N/A 
N/A 
         
  Marking of loudspeaker terminals 
N/A 
N/A 
dT (K) 
monitored point: 
264V 
90V 
Permitted dT (K) 
Metal enclosure 
11.8
 
11.1
 
40 
Plastic enclosure 
12.6
 
12.4
 
60 
Volume knob 
5.6
 
5.1
 
50 
Appliance inlet 
16.6
 
16.6
 
-- 
Internal primary wire 
27.3
 
27.4
 
60 
Capacitor C13 
23.3
 
23.4
 
75 
Capacitor C1 
22.9
 
23.2
 
75 
Winding of T1 
25.2
 
27.5
 
120(130-10)* 
Capacitor C4 
23.2
 
25.6
 
75 
Winding of T2 
25.9
 
30.8
 
120(130-10)* 
Capacitor C5 
25.7
 
29.3
 
75 
Winding of T3 
40.0
 
44.2
 
95(105-10)* 
Bobbin of T3 
43.5
 
44.3
 
125 
Bobbin of transformer T4 
60.3
 
60.6
 
125 
Winding of transformer T4 
63.5
 
64.1
 
95(105-10)* 
Bobbin of transformer T5 
52.7
 
53.5
 
125 
Winding of transformer T5 
49.4
 
50.2
 
95(105-10)* 
 
                                                                      Page 34 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Operating conditions 
Capacitor C7 
34.8
 
35.6
 
50 
PCB near BL1 
31.1
 
36.4
 
85 
PCB near IC7 
33.4
 
33.7
 
85 
Capacitor C50 
48.2
 
48.7
 
50 
Relay K1 body 
36.5
 
36.6
 
60 
Capacitor C33 
33.6
 
33.6
 
50 
Relay RL3 body 
14.7
 
14.3
 
60 
Capacitor EC77 
18.9
 
18.9
 
50 
Enclosure of DVD player 
8.1
 
7.0
 
60 
Motor of DVD-ROM 
9.8 9.4 -- 
Ambient temperature  
23.8 24.0 -- 
Note: * indicated thermocouple method was used to measure the winding, so the limit value reduced 10K. 
 
winding temperature rise measurements: 
 
 
Ambient temperature t1(
°C) 
-- 
 
 
Ambient temperature t2(
°C) 
-- 
 
Temperature rise dT of winding: 
R1 (Ω) R2 (Ω) 
dT (K) 
required 
dT (K) 
Insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
7.2 
TABLE: softening temperature of thermoplastics 
Pass 
 
Temperature T of part 
T - normal condi-
tions (
o
C) 
T - fault condi-
tions (
o
C) 
T softening 
(
o
C) 
Transformer T4 bobbin  
68.7 
102.0 
150 
Transformer T5 bobbin 
68.0 
101.7 
150 
 
 
                                                                      Page 35 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Line to Neutral with fuse removed (BI) 
>50 
Line / Neutral and secondary circuits (RI) 
>50 
Line / Neutral and accessible parts (RI) 
>50 
Transformer T4: Primary and secondary (RI) 
>50 
Transformer T5: Primary and secondary (RI) 
>50 
 
 
10.3 
TABLE: electric strength measurements 
Pass 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Line to Neutral with fuse removed (BI) 
2120Vp 
No 
Line / Neutral and secondary circuits (RI) 
4240Vp 
No 
Line / Neutral and accessible parts (RI) 
4240Vp 
No 
Transformer T4: Primary and secondary (RI) 
4240Vp 
No 
Transformer T5: Primary and secondary (RI) 
4240Vp 
No 
 
 
11.2 
TABLE: summary of fault condition tests 
Pass 
         
 
Model/type of power supply  .................................: -- 
— 
 
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240V~ 
 
         
 
Ambient temperature (
o
C) ...................................... : 22-24
 o
— 
 
No.  Component 
No. 
Fault  Test 
voltage 
(V) 
Test 
time 
Fuse 
No. 
Fuse 
current
(A) 
Result 
Dielectric 
strength 
test after 
the test 
1.  Volume 
Max.  264 
4hrs 
FH1 
0.452  Normal working.            
Winding of T4: 73.9K 
Bobbin of T4: 78.9K. No 
hazards. 
No  
2.  Volume 
Max.  90 
4hrs 
FH1 
1.336  Normal working.            
Winding of T4: 81.9K 
Bobbin of T4: 86.8K. No 
hazards. 
No  
3.  One output  SC 
264 
30min.  FH1 
0.191  Circuit protected, no hazards, 
no high temperature. 
No 
4.  BL1 SC 
264 
sec 
FH1 
>10 →
Current is >2.1 times fuse 
rating within 1 sec. Fuse 
opened immediately. No 
hazards. 
No 
 
                                                                      Page 36 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
5.  C6 SC 
264 
sec 
FH1 
>10 →
Current is >2.1 times fuse 
rating within 1 sec. Fuse 
opened immediately. No 
hazards. 
No 
6.  D4 
SC 
264 
30min.  FH1 
0.125  Circuit protected, no hazards, 
no high temperature. 
No 
7.  C44 SC 
264 
30min. 
FH1 
0.127 
Circuit protected, no hazards, 
no high temperature. 
No 
8.  D3 
SC 
264 
30min.  FH1 
0.124  Circuit protected, no hazards, 
no high temperature. 
No 
9.  C45 SC 
264 
30min. 
FH1 
0.125 
Circuit protected, no hazards, 
no high temperature. 
No 
10.  D6 
SC 
264 
30min.  FH1 
0.064  Circuit protected, no hazards, 
no high temperature. 
No 
11.  C68 SC 
264 
30min. 
FH1 
0.145 
Circuit protected, no hazards, 
no high temperature. 
No 
12.  D7 
SC 
264 
30min.  FH1 
0.064  Circuit protected, no hazards, 
no high temperature. 
No 
13.  C69 SC 
264 
30min. 
FH1 
0.150 
Circuit protected, no hazards, 
no high temperature. 
No 
14.  D18 SC 
264 
30min. 
FH1 
0.064 
Circuit protected, no hazards, 
no high temperature. 
No 
15.  C72 SC 
264 
30min. 
FH1 
0.064 
Circuit protected, no hazards, 
no high temperature. 
No 
16.  Optocoupler 
IC6 Sec. 
SC 
264 
30min.  FH1 
0.135  Circuit protected, no hazards, 
no high temperature. 
No 
17.  Optocoupler 
IC7 Sec. 
SC 
264 
30min.  FH1 
0.228  Normal work, no hazards, no 
high temperature. 
No 
18.  Optocoupler 
IC8 Sec. 
SC 
264 
30min.  FH1 
0.064  Circuit protected, no hazards, 
no high temperature. 
No 
19.  Output 
(+35V to 
GND) 
SC 
264 
30min.  FH1 
0.134  Circuit protected, no hazards, 
no high temperature. 
No 
20.  Output 
(+15V to 
GND) 
SC 
264 
30min.  FH1 
0.145  Circuit protected, no hazards, 
no high temperature. 
No 
21.  Output (-15V 
to GND) 
SC 
264 
30min.  FH1 
0.152  Circuit protected, no hazards, 
no high temperature. 
No 
22.  Output 
(+5.6V to 
GND) 
SC 
264 
30min.  FH1 
0.064  Circuit protected, no hazards, 
no high temperature. 
No 
Page of 54