Page 17 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω at 25 A ................... : N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
Detachable power cord.
N/A
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N/A
15.3.2
Reliable connection of non-detachable cords:
N/A
Not soldered to conductors of a printed circuit
board
board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N/A
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
N/A
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
table 16
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N/A
Page 18 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
The EUT is not a direct plug-in
apparatus.
apparatus.
N/A
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N/A
16
EXTERNAL FLEXIBLE CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
PVC Pass
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
Detachable cord used.
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
N/A
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N/A
16.5
Adequate strain relief on external flexible cords
Detachable power cord.
N/A
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible cord
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
Approved appliance inlet is
provided.
provided.
N/A
Page 19 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
17 ELECTRICAL
CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
Pass
- screws into metal: 5 times
Pass
- screws into non-metallic material: 10 times
Pass
17.2
Correct introduction into female threads in non-
metallic material
metallic material
Pass
17.3
Cover fixing screws: captive
N/A
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
Pass
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
Pass
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
Pass
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Pass
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
No picture tube
N/A
Picture tube separately approved to 18.1 ...............
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Page 20 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N/A
18.3 Non-intrinsically
protected tubes tested to 18.3
N/A
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ................. : Approx. 4.6kg
N/A
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
N/A
19.2
100 N force applied vertically downwards
N/A
19.3
Apparatus mass > 25 kg or height > 1 M or
supplied with cart or stand
supplied with cart or stand
N/A
19.4
Edges or corners not hazardous
There are no hazardous edges
or corners.
or corners.
Pass
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
No glass surface.
N/A
19.6
Wall or ceiling mountings adequate
Not wall or ceiling mounting.
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
Metal enclosure
N/A
b) Exemption for small components as defined in
20.1
20.1
Components are mounted on a
PCB of V-0.
PCB of V-0.
Pass
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components comply
with flammability requirements
in clause14.
with flammability requirements
in clause14.
Pass
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
N/A