Harman Kardon MAS 100-110 (serv.man2) EMC - CB Certificate ▷ View online
Page 9 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
No such device.
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
Pass
8.21
Bridging components comply with clause 14
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1: 3.2Vp, U2: 0.076Vp
Pass
Discharge not exceeding 45 µC Max.
0.5µC Pass
Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
Pass
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
Pass
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
Pass
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
Max. 12V after 2s
Pass
If C is not greater than 0,1 µF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
Pass
Test probe 11 of IEC 61032 for 10 s (50 N)
Pass
Test hook of fig. 4 for 10 s (20 N)
Pass
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N
Pass
9.2
No hazard after removing a cover by hand
N/A
Page 10 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
(see appended table)
Pass
10.2
Humidity treatment 48 h or 120 h ........................... : 93%RH, 30°C, 48h Pass
10.3
Insulation resistance and dielectric strength
(see appended table)
Pass
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
Pass
11.2
Heating under fault condition
Pass
No hazard from softening solder
No softening solder
N/A
11.2.1
Measurement of temperature rises
(see appended table)
Pass
11.2.2
Temperature rise of accessible parts
(see appended table)
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table)
Pass
11.2.5
Temperature rise of windings
(see appended table)
Pass
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table)
Pass
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
Approx. 4.6kg
Pass
Page 11 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
12.1.2 Vibration
test
Not carried out. As no
connection or part, which might
impair safety, can become
loose.
connection or part, which might
impair safety, can become
loose.
Pass
12.1.3
Impact hammer test
0.5J applied to the whole
enclosure, no hazard.
enclosure, no hazard.
Pass
Steel ball test
Pass
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
No damage after test with
100N periphery torque or axial
pull force.
100N periphery torque or axial
pull force.
Pass
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawer is provided
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial socket is
provided.
provided.
N/A
12.6
Telescoping or rod antennas construction
No such device.
N/A
12.6.1
Telescoping or rod antennas securement
No such device.
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
Pass
13.3
Clearances
(see appended table)
Pass
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
(see appended table)
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.4
Creepage distances
(see appended table)
Pass
Creepage distances greater than table 11 minima (see appended table)
Pass
13.5
Printed boards
No such printed board used.
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
Page 12 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 COMPONENTS
14.1 Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
R54 Pass
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors
separately approved .............................. : Tested within appliance.
N/A
14.2
Capacitors and RC units
Pass
Capacitors separately approved
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y2 capacitor C2, C3, C42, C43
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2 capacitor C1, C13, C4, C5
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such capacitor.
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
Metal case capacitors.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
Metal case capacitors.
N/A
Shielded by a barrier to V-0 or metal ..................... : No
N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
No, tested with appliance.
N/A