                                                                      Page 9 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
All-pole switch or circuit breaker with >3mm 
contact separation 
No such device. 
N/A 
8.19.2 
Mains switch ON indication 
 
N/A 
8.20 
Switch not fitted in the mains cord 
 
Pass  
8.21 
Bridging components comply with clause 14 
 
N/A 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. :
U1: 3.2Vp, U2: 0.076Vp 
Pass 
 
Discharge not exceeding 45 µC Max. 
0.5µC Pass 
 
Energy of discharge not exceeding 350 mJ 
 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
Pass 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 Pass 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
 Pass 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
 Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
 Pass 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
Max. 12V after 2s 
Pass 
 
If C is not greater than 0,1 µF no test needed 
 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 
Pass 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
Pass 
 
Test hook of fig. 4 for 10 s (20 N) 
 
Pass 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N 
Pass 
9.2 
No hazard after removing a cover by hand 
 
N/A 
 
 
 
                                                                      Page 10 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. :
(see appended table) 
Pass 
10.2 
Humidity treatment 48 h or 120 h ........................... : 93%RH, 30°C, 48h Pass 
10.3 
Insulation resistance and dielectric strength 
(see appended table) 
Pass 
 
 
11 FAULT 
CONDITIONS 
 
11.1 
No shock hazard under fault condition 
 
Pass 
11.2 
Heating under fault condition 
 
Pass 
 
No hazard from softening solder 
No softening solder 
N/A 
11.2.1 
Measurement of temperature rises 
(see appended table) 
Pass 
11.2.2 
Temperature rise of accessible parts 
(see appended table) 
Pass 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(see appended table) 
Pass 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm²
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
(see appended table) 
Pass 
11.2.5 
Temperature rise of windings 
(see appended table) 
Pass 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table) 
Pass 
 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
Approx. 4.6kg 
Pass 
 
                                                                      Page 11 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
12.1.2 Vibration 
test 
Not carried out. As no 
connection or part, which might 
impair safety, can become 
loose. 
Pass 
12.1.3 
Impact hammer test 
0.5J applied to the whole 
enclosure, no hazard. 
Pass 
 
Steel ball test 
 
Pass 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
 N/A 
12.1.5 
Thermoplastic enclosures stress relief test 
 
N/A 
12.2 
Fixing of knobs, push buttons, keys and levers 
No damage after test with 
100N periphery torque or axial 
pull force. 
Pass 
12.3 
Remote controls with hazardous live parts 
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawer is provided 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
No antenna coaxial socket is 
provided. 
N/A 
12.6 
Telescoping or rod antennas construction 
No such device. 
N/A 
12.6.1 
Telescoping or rod antennas securement 
No such device. 
N/A 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
 
Pass 
 
Creepage distances in accordance with 13.4 
 
Pass 
13.2 
Determination of operating voltage 
 
Pass 
13.3 
Clearances 
(see appended table) 
Pass 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
(see appended table) 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
 N/A 
13.4 
Creepage distances 
(see appended table) 
Pass 
 
Creepage distances greater than table 11 minima  (see appended table) 
Pass 
13.5 
Printed boards 
No such printed board used. 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N/A 
 
                                                                      Page 12 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N/A 
 
 
14 COMPONENTS 
 
14.1 Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
R54 Pass 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 Resistors 
separately approved  .............................. : Tested within appliance. 
N/A 
14.2 
Capacitors and RC units 
 
Pass 
 
Capacitors separately approved 
 
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. : Y2 capacitor C2, C3, C42, C43  
Pass 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. : X2 capacitor C1, C13, C4, C5 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... :
No such capacitor. 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
Metal case capacitors. 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
Metal case capacitors. 
N/A 
 
Shielded by a barrier to V-0 or metal ..................... : No 
N/A 
14.3 
Inductors and windings 
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
No, tested with appliance. 
N/A 
Page of 54