Page 21 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
PCB V-0.
Pass
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
The bobbin of transformer T4,
T5: V-0
T5: V-0
Pass
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such barrier.
N/A
20.2 Fire
enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Page 22 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2 Humidity
treatment
carried out for 7 days
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
N/A
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N/A
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
Pass
Page 23 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
No socket-outlets.
N/A
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
No socket-outlets.
N/A
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
No socket-outlets.
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
N/A
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
N/A
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
N/A
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
N/A
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
N/A
- protecting rim also tested
N/A
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N/A
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N/A
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
5
DE: additional markings required in German language:
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No CRT used.
N/A
Page 24 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N/A
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: certification number on the back cover
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
N/A
Amendment 1 to IEC/EN 60065, 7th edition
5.4.1
A warning that batteries (battery pack or batteries
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
N/A
Special stability warning for the apparatus with
CRT
CRT
Warning: the CRT in this product employs a
protective film on the face. This film must not be
removed as it serves a safety function and removal
will increase the risk of serious injury.
protective film on the face. This film must not be
removed as it serves a safety function and removal
will increase the risk of serious injury.
N/A
8.7 Void
N/A
8.8
For requirements for non-separable thin sheet
insulation in two or more layers, see 8.XX.
insulation in two or more layers, see 8.XX.
N/A
8.22
Requirements for non-separable thin sheet
insulation in two or more layers
insulation in two or more layers
N/A
15.2
Delete the paragraph: In supply apparatus of
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
N/A
18.1
Protective film as part of the implosion protection
system: all edges covered by the enclosure of the
apparatus
system: all edges covered by the enclosure of the
apparatus
N/A
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
to point of least stability.
N/A