                                                                      Page 21 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
PCB V-0. 
Pass 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
 N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
The bobbin of transformer T4, 
T5: V-0 
Pass 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
No such barrier. 
N/A 
20.2 Fire 
enclosure 
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
 N/A 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N/A 
 
 
                                                                      Page 22 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 N/A 
A.10.2.2 Humidity 
treatment 
carried out for 7 days 
 
N/A 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1 
 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
 N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
 N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 
 
 
ZB 
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS 
 
2.6.1 
DK: certain types of Class I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
 
N/A 
13.3.1 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
 
N/A 
15.1.1 
DK: mains cord for single-phase equipment having 
a rated current not exceeding 10 A shall be 
provided with a plug according to Heavy Current 
Regulations Section 107-2-D1 
 
Pass 
 
                                                                      Page 23 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
DK: Class I equipment with socket-outlets with 
earthing contact, or which are intended to be used 
in locations where protection against indirect 
contact is required shall be provided with a plug in 
compliance with Standard Sheet DK 2-1a 
No socket-outlets. 
N/A 
 
DK: socket-outlets for providing power to Class II 
equipment with a  rated current of 2,5 A shall have 
dimensions according to the drawing on page 131 
of EN 60 065:98 other dimensions shall be to 
IEC 60 083 Standard Sheet C 1a for portable 
socket-outlets 
No socket-outlets. 
N/A 
 
DK: mains socket-outlets with earthing contact 
shall comply with Heavy Current Regulations 
Section 107-2-D1, Standard Sheet DK 1-3a, 
DK 1-5a or DK 1-7a 
No socket-outlets. 
N/A 
 
GB: equipment fitted with a flexible cable or cord 
provided with a 13A BS 1363 plug as in Statutory 
Instrument 1768:94 
 
N/A 
 
IE: equipment fitted with a flexible cable or cord 
provided with a 13 A plug in accordance with 
Statutory Instrument 525:97 
 
N/A 
 
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the 
following amendments: 
N/A 
 
- dimensions 2,5 A, 250 V socket-outlets shall 
comply with Standard Sheet 1 page 132 of 
EN 60 065:98 
 
N/A 
 
- mechanical strength 2,5 A, 250 V socket-outlets 
tested as specified in EN 60 065, 12.1.3 
 
N/A 
 
- protecting rim also tested 
 
N/A 
 
NO: method b) of 8.1 is not permitted. Double or 
reinforced insulation is required between parts 
connected to the mains and parts connected to the 
public telecommunications network 
 
N/A 
J.2 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
 
N/A 
 
 
ZC 
ANNEX ZC TO EN 60 065, A-DEVIATIONS 
 
DE: additional markings required in German language: 
 
 
- cathode ray tubes with an accelerating voltage 
between 20 kV and 30 kV (marking on the tube) 
No CRT used. 
N/A 
 
                                                                      Page 24 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
- TV receivers whose picture tube has an 
accelerating voltage between 20 kV and 30 kV 
 
N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage greater than 30 kV 
 
N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage less than 20 kV 
 
N/A 
5.1 
IT: additional markings on the outside of the TV 
receiver in Italian language 
 
N/A 
 
IT: user instructions in Italian language including a 
conformity declaration 
 
N/A 
 
IT: certification number on the back cover 
 
N/A 
14 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
 
N/A 
 
 
Amendment 1 to IEC/EN 60065, 7th edition 
 
5.4.1 
A warning that batteries (battery pack or batteries 
installed) shall not be exposed to excessive heat 
such as sunshine, fire or the like. 
 N/A 
 
Special stability warning for the apparatus with 
CRT 
Warning: the CRT in this product employs a 
protective film on the face. This film must not be 
removed as it serves a safety function and removal 
will increase the risk of serious injury. 
 N/A 
8.7 Void 
 
N/A 
8.8 
For requirements for non-separable thin sheet 
insulation in two or more layers, see 8.XX. 
 N/A 
8.22 
Requirements for non-separable thin sheet 
insulation in two or more layers 
 N/A 
15.2 
Delete the paragraph:  In supply apparatus of 
Class I with non-hazardous live output voltage: 
output circuit shall not be connected to the 
protective earthing conductor. 
 N/A 
18.1 
Protective film as part of the implosion protection 
system:  all edges covered by the enclosure of the 
apparatus 
 N/A 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability. 
 N/A 