Harman Kardon DVD 39 (serv.man2) EMC - CB Certificate ▷ View online
- Page 29 of 42 -
Report
No.
98390
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
PCB are of base
material with flammability
category V-0 or better.
See appended table
material with flammability
category V-0 or better.
See appended table
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
The PCB are of base
material with flammability
category V-0.
See appended table
material with flammability
category V-0.
See appended table
P
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
No such components
N/A
Components and parts as above but shielded
from a potential ignition source, with the barrier
area in accordance with Table 21 and fig. 13
from a potential ignition source, with the barrier
area in accordance with Table 21 and fig. 13
No such components
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the
enclosure exceed those specified Table 21,
flammability classification HB40 or better is
required for the enclosure.
operating conditions and distances to the
enclosure exceed those specified Table 21,
flammability classification HB40 or better is
required for the enclosure.
Normal operating voltage
is
is
< 4KV
N/A
20.2 Fire
enclosure
N/A
20.2.1
Potential ignition sources with open circuit
voltage > 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
voltage > 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltages exceeding
4kV, no fire enclosure
requirement
4kV, no fire enclosure
requirement
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
No internal fire enclosure.
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
No internal fire enclosure.
N/A
- Page 30 of 42 -
Report
No.
98390
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does
not apply
not apply
Not intended for outdoor use
N/A
A.10.2.1
Enclosure provides protection against
splashing water
splashing water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
See clause above
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with
3.5.4 modified to 2.4.10 of this standard
3.5.4 modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with
4.1.2, 4.1.3 and 4.2.1.2 modified in accordance
with annex B of this standard
4.1.2, 4.1.3 and 4.2.1.2 modified in accordance
with annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
- Page 31 of 42 -
Report
No.
98390
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to
the building installation via a non-industrial
plug or a non-industrial appliance coupler, or
both and in addition is intended for connection
to other equipment or a network shall, if safety
relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts,
have a marking stating that the equipment
must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries
shall be as follow:
In Finland,
"Laite on liitettävä
suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to
the building installation via a non-industrial
plug or a non-industrial appliance coupler, or
both and in addition is intended for connection
to other equipment or a network shall, if safety
relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts,
have a marking stating that the equipment
must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries
shall be as follow:
In Finland,
"Laite on liitettävä
suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Class II apparatus
N/A
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
N/A
L5.4
Marking and Instructions
N/A
L9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in
Table 3 , unless comply with 6.3.2 of IEC
60086-4
Table 3 , unless comply with 6.3.2 of IEC
60086-4
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
No electronic flash
apparatus
apparatus
N/A
-
Page 32 of 42 -
Report
No.
98390
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
No mains switch
—
Position of the functional switch (W) ................ :
In OFF/Stand-by position,
the power consumption is
less than 1,0W.
the power consumption is
less than 1,0W.
—
Operating conditions
Standby mode at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0,021 1,0 —
220 0,021 1,0 —
Standby mode at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0,020 1,0 —
220 0,020 1,0 —
Measured on DVD play with HDMI mode at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
253
0,149 16,9 —
230
0,159 16,7 —
220
0,164 16,7 —
198
0,175 16,4 —
Measured on DVD play with HDMI mode at 60Hz;
253
0,128 16,8 —
242
0,134 16,8 —
230
0,139 16,7 —
220
0,145 16,5 —
198
0,154 16,4 —
Click on the first or last page to see other DVD 39 (serv.man2) service manuals if exist.