Harman Kardon DVD 39 (serv.man2) EMC - CB Certificate ▷ View online
- Page 21 of 42 -
Report
No.
98390
14.5.2.2
Correct marking of fuse-links adjacent to holder
................................................................................. :
................................................................................. :
Correct marking provided
in adjacent of fuse:
F901: 250V T2A L
in adjacent of fuse:
F901: 250V T2A L
P
14.5.2.3
Not possible to connect fuses in parallel ......... :
No fuses holder so
designed that fuse-links
can be connected in parallel
designed that fuse-links
can be connected in parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .. :
replacing fuse-links without the use of a tool .. :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No PTC’s thermistors.
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking
capacity and their position is correctly marked
capacity and their position is correctly marked
N/A
14.6 Switches
No mains switches
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
Make and break speed independent of speed of
actuation
actuation
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
- Page 22 of 42 -
Report
No.
98390
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
No mains socket outlets
N/A
Socket outlet current marking correct
N/A
14.7 Safety
interlocks
No safety interlock
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
and the like
No voltage setting devices
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
Only secondary low voltage
DC motors for DVD player.
No special test is necessary
DC motors for DVD player.
No special test is necessary
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-
phase motors and series motors meet clause. B.8,
B.9 and B.10 of IEC 60950, Annex B
phase motors and series motors meet clause. B.8,
B.9 and B.10 of IEC 60950, Annex B
N/A
14.10 Batteries
No batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
- Page 23 of 42 -
Report
No.
98390
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
P
Optocouplers comply with Cl. 8
Insulation thickness > 0,4mm
P
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
Internal/external creepage
and clearance distances are
> 4mm / > 5mm.
See list of critical component
s
and clearance distances are
> 4mm / > 5mm.
See list of critical component
s
P
14.12
Surge suppression varistors
P
Comply with IEC 61051-2
VT91, across the mains.
Comply with IEC 61051-2.
Comply with IEC 61051-2.
P
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
No such application
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
Approved varistor used.
Complies.
Complies.
P
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Approved appliance inlet
and coupler provided, see
list of critical components
and coupler provided, see
list of critical components
P
Overloading of plugs or appliance inlets
prevented if the apparatus has mains socket
outlets
prevented if the apparatus has mains socket
outlets
No mains socket outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
No mains socket outlets
N/A
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
Signal input/output connector
s
are so designed that plug
insertion in to mains socket-
outlet or appliance is unlikely
to occur.
s
are so designed that plug
insertion in to mains socket-
outlet or appliance is unlikely
to occur.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No sockets indicated with
the symbol
the symbol
N/A
- Page 24 of 42 -
Report
No.
98390
15.1.3
Output terminals of a.c. adaptors or similar
devices not compatible with household mains
socket-outlets
devices not compatible with household mains
socket-outlets
The equipment under test
is not an adaptor.
is not an adaptor.
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω at 25 A ............... :
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
Appliance inlet applied
N/A
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
.
N/A
15.3.2
Reliable connection of non-detachable cords:
Detachable cord provided
N/A
Not soldered to conductors of a printed circuit
board
board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the
conductor
conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
Screws and nets are
not used
not used
N/A
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
Conductor hooked-in
before soldered
before soldered
P
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
Clamped insulators and
conductors
conductors
P
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N/A
Click on the first or last page to see other DVD 39 (serv.man2) service manuals if exist.