Harman Kardon DVD 39 (serv.man2) EMC - CB Certificate ▷ View online
-
Page 33 of 42 -
Report
No.
98390
Monitored point:
dT (K) at
253V, 50Hz
dT (K) at
198V, 50Hz
dT (K) at
253V, 60Hz
dT (K) at
198V, 60Hz
Limit dT (K)
*)
LF91 coil
20,5
17,9
20,3
18,0
60 **)
LF92 coil
22,0
20,4
22,0
20,2
60 **)
PWB near D901
26,7
22,8
26,6
23,7
70
E-capacitor, C901 body
24,9
21,5
24,7
22,2
70
Spindle motor body
13,2
11,7
13,4
12,0
-
TF91 coil
31,6
27,5
30,6
28,6
60 **)
TF91 core
30,1
26,6
29,8
27,4
70
TF92 coil
43,3
38,7
42,7
39,5
60 **)
TF92 core
39,1
34,7
38,4
35,4
70
PWB near D936
40,1
36,7
39,7
37,4
70
IC21 heat-sink
44,6
42,7
44,8
43,4
-
PWB near IC21
38,7
36,8
38,9
37,6
70
Inlet body (Inside)
15,8
13,4
15,8
13,8
50
Top enclosure above TF92
14,5
12,8
15,0
13,0
40
Top enclosure above IC21
13,4
12,0
14,2
12,6
40
Standby button (Non-metallic)
9,3
8,2
10,4
8,8
50
Front panel (Non-metallic)
4,3
4,7
7,4
5,1
50
Ambient
22,5 25,8 22,3 24,8 -
*) Temperature rise limits for Singapore is 10K less.
**) Minus 10K applied for thermo-couple method for windings
-
Page 34 of 42 -
Report
No.
98390
Monitored point:
dT (K) at
198V, 60Hz
dT (K) at
242V, 60Hz
Limit dT (K)
LF91 coil
18,0
20,7
60 *)
LF92 coil
20,2
22,4
60 *)
PWB near D901
23,7
27,0
70
E-capacitor, C901 body
22,2
25,3
70
Spindle motor body
12,0
14,0
-
TF91 coil
28,6
31,8
60 *)
TF91 core
27,4
30,7
70
TF92 coil
39,5
43,5
60 *)
TF92 core
35,4
39,3
70
PWB near D936
37,4
40,4
70
IC21 heat-sink
43,4
45,5
-
PWB near IC21
37,6
39,7
70
Inlet body (Inside)
13,8
16,3
50
Top enclosure above TF92
13,0
15,1
40
Top enclosure above IC21
12,6
14,3
40
Standby button (Non-metallic)
8,8
10,4
50
Front panel (Non-metallic)
5,1
6,2
50
Ambient
24,8
22,9
-
*) Minus 10K applied for thermo-couple method for windings
-
Page 35 of 42 -
Report
No.
98390
7.2
TABLE: softening temperature of thermoplastics
N/A
Temperature T of part
T - normal con-
ditions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
2
Between parts separated by double or reinforced insulation
> 100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500Vac No
Between parts separated by double or reinforced insulation
3000Vac No
-
Page 36 of 42 -
Report
No.
98390
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ......... :
253V or 198V
—
Ambient temperature (
o
C) ................................... :
23 - 26
o
C
—
Monitored point:
Under fault conditions specified below
Under fault conditions specified below
dT (K)
Limit dT (K)
#)
*), D902 (A to C), S-c;
F901 opened immediately. No hazard
F901 opened immediately. No hazard
N/A N/A
**), D904 (A to C), S-c;
F901 opened immediately. No hazard
F901 opened immediately. No hazard
N/A N/A
*), C901, S-c;
F901 opened immediately. No hazard.
F901 opened immediately. No hazard.
N/A N/A
*), IC92 (pin5 to pin7), S-c;
F901 opened immediately. IC92, Q901 and D909 damaged. No hazard.
F901 opened immediately. IC92, Q901 and D909 damaged. No hazard.
N/A N/A
*), IC92 (pin5 to pin2), S-c;
F901 opened immediately. D908 damaged. No hazard.
F901 opened immediately. D908 damaged. No hazard.
N/A N/A
*), IC91 (pin4 to pin6), S-c;
F901 opened immediately. D906 damaged. No hazard.
F901 opened immediately. D906 damaged. No hazard.
N/A N/A
*), IC91 (pin4 to pin3), S-c;
F901 opened immediately. IC91 and R914 damaged. No hazard.
F901 opened immediately. IC91 and R914 damaged. No hazard.
N/A N/A
*), D940 (A to C), S-c;
FL display and signal output off immediately.
TF92 coil winding temperature stabilised. Input current stabilised at 0,064A.
No component damaged. No hazard (Tested time: 1 hr 10 min).
FL display and signal output off immediately.
TF92 coil winding temperature stabilised. Input current stabilised at 0,064A.
No component damaged. No hazard (Tested time: 1 hr 10 min).
TF92 transf.
30,3
TF92 transf.
90 ***)
*), C961, S-c;
Signal output off immediately. Input current stabilised at 0,030A.
No component damaged. No hazard (Tested time: 20 min).
Signal output off immediately. Input current stabilised at 0,030A.
No component damaged. No hazard (Tested time: 20 min).
N/A N/A
*), D939 (A to C), S-c;
FL display and signal output off immediately.
Input current stabilised at 0,029A. No component damaged.
No hazard (Tested time: 20 min).
FL display and signal output off immediately.
Input current stabilised at 0,029A. No component damaged.
No hazard (Tested time: 20 min).
N/A N/A
*), C960, S-c;
Signal output off immediately. Input current stabilised at 0,030A.
No component damaged. No hazard (Tested time: 30 min).
Signal output off immediately. Input current stabilised at 0,030A.
No component damaged. No hazard (Tested time: 30 min).
N/A N/A
*), D936 (A to C), S-c;
FL display and signal output off immediately.
Input current stabilised at 0,029A. No component damaged.
No hazard (Tested time: 40 min).
FL display and signal output off immediately.
Input current stabilised at 0,029A. No component damaged.
No hazard (Tested time: 40 min).
N/A N/A
*) Tested voltage 253V **) Tested voltage 198V
***) Minus 10K applied for thermo-couple method for windings
#) Temperature rise limits for Singapore is 10K less
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded