Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Withstand 4240Vp test.
Pass
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
N/A
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
N/A
8.10
Double insulation between conductors connected to
the mains and accessible parts
the mains and accessible parts
Live wires are double
insulated, no secondary wire
can come closer to live parts
insulated, no secondary wire
can come closer to live parts
Pass
8.11
Detaching of wires
N/A
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Mating lock connector used
for mains. No risk of
detached.
for mains. No risk of
detached.
N/A
Vibration
test carried out ........................................ : No, see above
N/A
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
N/A
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Pass
8.14
Adequate fastening of covers (pull test 50 N for 10 s) Pass
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Internal wires secured and
keep enough distance from
sharp or hot parts.
keep enough distance from
sharp or hot parts.
Pass
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Pass
8.19.1 Disconnect
device
Mains
plug
Pass
All-pole switch or circuit breaker with >3mm contact
separation
separation
Not used as a disconnect
device
device
N/A
8.19.2
Mains switch ON indication
Not used as a disconnect
device
device
N/A
8.20
Switch not fitted in the mains cord
Pass
8.21
Bridging components comply with clause 14
N/A
page 8 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
Pass
9.1
Testing on the outside
Pass
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such high voltage
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1<0.86Vp
U2<0.113Vp
U2<0.113Vp
Pass
Discharge not exceeding 45 μC <1μC Pass
Energy of discharge not exceeding 350 mJ
No voltage exceeding 15kV
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or levers Pass
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
< 2 mm, no entering
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set control
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
< 5V
Pass
If C is not greater than 0,1 μF no test needed
> 0.2 μF
N/A
9.1.7
Enclosure sufficiently resistant to external force
Pass
Test probe 11 of IEC 61032 for 10 s (50 N)
Pass
Test hook of fig. 4 for 10 s (20 N)
Pass
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N Pass
9.2
No hazard after removing a cover by hand
Can not be removed by hand
N/A
10 INSULATION
REQUIREMENTS
Pass
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
No antenna terminal.
N/A
10.2 Humidity
treatment 48 h or 120 h ........................... : 120h, 40℃, 93%R.H.
Pass
10.3
Insulation resistance and dielectric strength
(See appended table)
Pass
11 FAULT
CONDITIONS
Pass
11.1
No shock hazard under fault condition
Pass
page 9 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
11.2
Heating under fault condition
(See appended table)
Pass
No hazard from softening solder
Pass
11.2.1
Measurement of temperature rises
Pass
11.2.2
Temperature rise of accessible parts
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(See appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
Pass
11.2.5
Temperature rise of windings
(see appended table)
Pass
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
(see appended table)
Pass
12 MECHANICAL
STRENGTH
Pass
12.1.1
Bump test where mass >7 kg
3.7kg
N/A
12.1.2 Vibration
test
Not carried out, no
connection which might
impair safety can become
loosen
connection which might
impair safety can become
loosen
Pass
12.1.3
Impact hammer test
0.5J Pass
Steel ball test
2J Pass
12.1.4
Drop test for portable apparatus where mass < 7 kg Pass
12.1.5
Thermoplastic enclosures strain relief test
70
o
C, 7h
Pass
12.2
Fixing of knobs, push buttons, keys and levers
Pass
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
Pass
page 10 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
Pass
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
T502: pin3- 14, 250Vrms,
600Vp
600Vp
Pass
13.3 Clearances
Primary—secondary: 4.6mm
required
required
Primary (operating voltage:
240Vrms) —accessible parts
/ enclosure: 4.0mm required
240Vrms) —accessible parts
/ enclosure: 4.0mm required
Primary (operating voltage:
250Vrms, 600Vp) —
accessible parts / enclosure:
4.6mm required
250Vrms, 600Vp) —
accessible parts / enclosure:
4.6mm required
L-N before fuse link:
2.0mm required
T502: P—S: 4.6mm required
Pass
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9
with table 8 and, where applicable, table 9
Measured distance:
Primary—secondary:
>5.4mm
>5.4mm
Primary—accessible parts /
enclosure (operating voltage:
240Vrms): >4.7mm
enclosure (operating voltage:
240Vrms): >4.7mm
Primary—accessible parts /
enclosure (operating voltage:
250Vrms, 600Vp): >5.4mm
enclosure (operating voltage:
250Vrms, 600Vp): >5.4mm
T502: P—S: >5.4mm
L-N before fuse link: >4.0mm
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N/A