Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate ▷ View online

 
 
page 7 of  63 
Ref. No. : JSH05110330-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
Reinforced insulation, three layers any two which 
meet 10.3 
Withstand 4240Vp test. 
Pass 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts 
           
N/A 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
           
N/A 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts 
Live wires are double 
insulated, no secondary wire 
can come closer to live parts 
Pass 
8.11 
Detaching of wires 
      
N/A 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
Mating lock connector used 
for mains. No risk of 
detached. 
N/A 
 Vibration 
test carried out  ........................................ :  No, see above 
N/A 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 N/A 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) 
 Pass 
8.14 
Adequate fastening of covers (pull test 50 N for 10 s)  Pass 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges 
Internal wires secured and 
keep enough distance from 
sharp or hot parts. 
Pass 
8.16 
Only special supply equipment can be used 
 N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
 
Pass 
8.19.1 Disconnect 
device 
Mains 
plug 
Pass 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
Not used as a disconnect 
device 
N/A 
8.19.2 
Mains switch ON indication 
Not used as a disconnect 
device 
N/A 
8.20 
Switch not fitted in the mains cord 
 
Pass 
8.21 
Bridging components comply with clause 14 
 
N/A 
 
 
 
 
 
 
page 8 of  63 
Ref. No. : JSH05110330-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
Pass 
9.1 
Testing on the outside 
Pass 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such high voltage 
N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. : 
U1<0.86Vp  
U2<0.113Vp 
Pass 
 
Discharge not exceeding 45 μC <1μC Pass 
 
Energy of discharge not exceeding 350 mJ 
No voltage exceeding 15kV 
N/A 
9.1.1.2 
Test with test finger and test probe 
 Pass 
9.1.2 
No hazardous live shafts of knobs, handles or levers  Pass 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin 
< 2 mm, no entering 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032 
 Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set control 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  : 
< 5V 
Pass 
 
If C is not greater than 0,1 μF no test needed 
> 0.2 μF 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 Pass 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 Pass 
 
Test hook of fig. 4 for 10 s (20 N) 
 
Pass 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... :  100N Pass 
9.2 
No hazard after removing a cover by hand 
Can not be removed by hand 
N/A 
 
 
 
10 INSULATION 
REQUIREMENTS 
Pass 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. : 
No antenna terminal. 
N/A 
10.2 Humidity 
treatment 48 h or 120 h ........................... :  120h, 40℃, 93%R.H. 
Pass 
10.3 
Insulation resistance and dielectric strength 
(See appended table) 
Pass 
 
 
 
 
11 FAULT 
CONDITIONS 
Pass 
11.1 
No shock hazard under fault condition 
           
Pass 
 
 
page 9 of  63 
Ref. No. : JSH05110330-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
11.2 
Heating under fault condition 
(See appended table) 
Pass 
 
No hazard from softening solder 
 
Pass 
11.2.1 
Measurement of temperature rises 
 
Pass 
11.2.2 
Temperature rise of accessible parts 
 
Pass 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(See appended table) 
Pass 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not more 
than 100 K for an area not greater than 2 cm² 
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
           
N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
           
Pass 
11.2.5 
Temperature rise of windings 
(see appended table) 
Pass 
11.2.6 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.5 
(see appended table) 
Pass 
 
 
 
12 MECHANICAL 
STRENGTH 
Pass 
12.1.1 
Bump test where mass >7 kg 
3.7kg 
N/A 
12.1.2 Vibration 
test 
Not carried out, no 
connection which might 
impair safety can become 
loosen 
Pass 
12.1.3 
Impact hammer test 
0.5J Pass 
 
Steel ball test 
2J Pass 
12.1.4 
Drop test for portable apparatus where mass < 7 kg   Pass 
12.1.5 
Thermoplastic enclosures strain relief test 
70
o
C, 7h 
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers 
 Pass 
12.3 
Remote controls with hazardous live parts 
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
 
Pass 
 
 
page 10 of  63 
Ref. No. : JSH05110330-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
12.5 
Antenna coaxial sockets providing isolation 
 
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
Pass 
13.1 
Clearances in accordance with 13.3 
 
Pass 
 
Creepage distances in accordance with 13.4 
  
Pass 
13.2 
Determination of operating voltage 
T502: pin3- 14, 250Vrms, 
600Vp 
Pass 
13.3 Clearances 
Primary—secondary: 4.6mm 
required 
Primary (operating voltage: 
240Vrms) —accessible parts 
/ enclosure: 4.0mm required 
Primary (operating voltage: 
250Vrms, 600Vp) —
accessible parts / enclosure: 
4.6mm required 
L-N before fuse link:  
2.0mm required 
T502: P—S: 4.6mm required 
Pass 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 
Measured distance:  
Primary—secondary: 
>5.4mm 
Primary—accessible parts / 
enclosure (operating voltage: 
240Vrms): >4.7mm 
Primary—accessible parts / 
enclosure (operating voltage: 
250Vrms, 600Vp): >5.4mm 
T502: P—S: >5.4mm 
L-N before fuse link: >4.0mm
 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
N/A 