Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate ▷ View online
page 3 of 63
Ref. No. : JSH05110330-002
Copy of marking plate
Marking plate for U.S.A
On DVD loader:
On DVD loader for U.S.A
page 4 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
3 GENERAL
REQUIREMENTS
Pass
Safety class of the apparatus ................................. : Class II Pass
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
Yes
Noted
5 MARKING
Pass
Comprehensible and easily discernible
Printed on the rear enclosure
Pass
Permanent durability against water and petroleum
spirit
spirit
Pass
5.1 Identification,
maker, model ................................... : harman/kardon Pass
Class II symbol if applicable
Pass
Rated supply voltage and symbol .......................... : 100-240V ~
Pass
Frequency if safety dependant
50/60Hz Pass
Rated current or power consumption .................... : 20W Pass
5.2 Earth
terminal
Class II
N/A
Hazardous live terminals
N/A
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
On PCB
Pass
5.4
Instructions for use
Pass
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
Pass
Hazardous live terminals, instructions for wiring
No such terminals
N/A
Instructions for replacing lithium battery
No lithium battery
N/A
Instructions for modem if fitted
No modem fitted
N/A
Class I earth connection warning
N/A
Instructions for multimedia system connection
Pass
Special stability warning for fixed installation
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Pass
Instructions for permanently connected equipment
N/A
page 5 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
6 HAZARDOUS
RADIATION
Pass
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
No ionizing radiation
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : Class 1
Pass
Emission limits under fault conditions .................... : Laser Optical Pickup:Class 1
Pass
7
HEATING UNDER NORMAL OPERATING CONDITIONS
Pass
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
Pass
7.1.1
Temperature rise of accessible parts
(see appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
Pass
7.1.4
Temperature rise of windings
(see appended table)
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such supporting parts
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
Pass
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB, windings
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
Pass
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
Tools are required
Pass
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
page 6 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Pass
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Pass
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
R574,T502 Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY2, CY3, CY501, CY502
Pass
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N/A
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V (peak)
a.c. or between 60 V and 120 V d.c. and hazardous
live parts at higher voltage
operating at voltages between 35 V and 71 V (peak)
a.c. or between 60 V and 120 V d.c. and hazardous
live parts at higher voltage
N/A
Separation by Class II isolating transformer
N/A
Separation by Class I transformer
N/A
Separation by earthed conductive part
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : T502 bobbin: 0.9mm
Optocoupler U502: 0.40mm
Enclosure (front panel):
>1.5mm
>1.5mm
Separation sheet on internal
enclosure under power
board: 0.5mm.
enclosure under power
board: 0.5mm.
Pass
Thin sheet insulation
Inside T502
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Click on the first or last page to see other DVD 23 (serv.man11) service manuals if exist.