Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate ▷ View online
page 11 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
13.4 Creepage
distances
Primary—secondary: on PCB
track 5.0mm required.
track 5.0mm required.
Primary—accessible parts /
enclosure (operating voltage:
240Vrms): on PCB track
5.0mm required.
enclosure (operating voltage:
240Vrms): on PCB track
5.0mm required.
Primary—accessible parts /
enclosure (operating voltage:
250Vrms, 600Vp): on PCB
track 5.0mm required.
enclosure (operating voltage:
250Vrms, 600Vp): on PCB
track 5.0mm required.
L-N before fuse link:
3.0mm required
T502: P—S: 5.0mm required.
Pass
Creepage distances greater than table 11 minima
Measured distance:
Primary—secondary:
>5.4mm
>5.4mm
Primary—accessible parts /
enclosure (operating voltage:
240Vrms): >6.0mm
enclosure (operating voltage:
240Vrms): >6.0mm
Primary—accessible parts /
enclosure (operating voltage:
250Vrms, 600Vp): >5.4mm
enclosure (operating voltage:
250Vrms, 600Vp): >5.4mm
T502: P—S: >5.4mm
L-N before fuse link: >4.0mm
Pass
13.5 Printed
boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains: clearances
and creepage distances as in table 12
not conductively connected to the mains: clearances
and creepage distances as in table 12
No such parts
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No such parts
N/A
page 12 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14 COMPONENTS
Pass
14.1 Resistors
Pass
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
R574 Pass
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
b) Resistors separately approved .......................... : R574 approved by VDE
Pass
14.2
Capacitors and RC units
Pass
Capacitors separately approved
Yes
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y1: CY2, CY3, CY50, CY502
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2: C502, C503
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such component
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better .................. :
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better .................. :
EC502 metal case
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ................................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ................................................ :
EC502 metal case
N/A
Shielded by a barrier to V-0 or metal ..................... : N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Switching mode transformer
T502: BCK-EC2846
Filter L512: LCL ET20-010
or ET20-50mH
Pass
Transformers and inductors separately approved . : No
N/A
14.3.2 General
Pass
14.3.3 Constructional
requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
Pass
14.3.3.2
Transformers meet the constructional requirements
Pass
page 13 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T502 basic insulation
minimum 3.0 mm between
T502 core and primary,
Supplementary insulation
minimum 3.0mm between
T502 core and secondary.
minimum 3.0 mm between
T502 core and primary,
Supplementary insulation
minimum 3.0mm between
T502 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T502 bobbin: 0.9mm
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II construction
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Iron cores in T502 are not
connected to primary parts or
accessible parts.
connected to primary parts or
accessible parts.
Pass
Coil formers and partition walls > 0,4 mm
T502 bobbin: 0.9mm
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II construction
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No such components
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
Pass
Protective devices used within their ratings
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Fuse F501: >3.5mm
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such components
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
No such components
N/A
b) Thermal links tested as part of the submission
N/A
page 14 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
F501 approved.
Pass
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : F501: T1A L 250V
Pass
14.5.2.3
Not possible to connect fuses in parallel ............... : Only one fuse holder
Pass
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
Pass
14.5.3
PTC-S thermistors comply with IEC 60730-1
No such parts
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
No such parts
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Click on the first or last page to see other DVD 23 (serv.man11) service manuals if exist.