Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate ▷ View online

 
 
page 19 of  63 
Ref. No. : JSH05110330-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
 
Pass 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
 
Pass 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
No such device 
N/A 
17.8 
Fixing devices for detachable legs or stands 
provided 
No such device 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
 Pass 
 
 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
N/A 
 
Picture tube separately approved to IEC 61965: 
No picture tube 
N/A 
 
Picture tube separately approved to 18.1 ............... No 
N/A 
18.1 
Picture tubes > 16 cm intrinsically protected 
           
N/A 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
           
N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples 
           
N/A 
18.2.1 
Samples subject to ageing: 6 
      
N/A 
18.2.2 
Samples subject to implosion test: 6 
           
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
           
N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 
           
N/A 
 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
Pass 
 
Mass of the equipment exceeding 7 kg  ................. : 3.7kg 
N/A 
 
Apparatus intended to be fastened in place – 
suitable instructions 
No 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
N/A 
19.2 
100 N force applied vertically downwards 
 
N/A 
19.3 
Apparatus mass > 25 kg or height > 1 M or 
supplied with cart or stand 
 N/A 
 
 
page 20 of  63 
Ref. No. : JSH05110330-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
19.4 
Edges or corners not hazardous 
 
Pass 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
No glass surface 
N/A 
19.6 
Wall or ceiling mountings adequate 
Not for wall or ceiling mounting 
N/A 
 
 
 
20 
RESISTANCE TO FIRE 
Pass 
20.1 
Electrical components and mechanical parts 
Pass 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 N/A 
 
b) Exemption for small components as defined in 
20.1 
See components list 
Pass 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 
See components list 
Pass 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 Kv or leaving an internal fire enclosure, not 
contributing to the spread of fire 
No voltage exceeding 4kV 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
Rated: V-0 
Pass 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
Rated: V-0 
Pass 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
See components list 
Pass 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 
N/A 
20.2 Fire 
enclosure 
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
 
N/A 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 N/A 
 
 
page 21 of  63 
Ref. No. : JSH05110330-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
           
N/A 
 
 
 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
IP20 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 
N/A 
A.10.2.2 Humidity 
treatment carried out for 7 days 
 
N/A 
 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
N/A 
 
Complies with IEC 62151 clause 1 
Not to be connected to the 
telecommunication networks 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 
 
 
 
 
 
page 22 of  63 
Ref. No. : JSH05110330-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
7.1 
TABLE: temperature rise measurements 
Pass 
 
Power consumption in the OFF/Stand-by 
Stand-by: <0.5W  
Pass 
 
Position of the functional switch (W)  ......................: On 
— 
Operating conditions 
25
o
C, normal DVD playing, operates for 4h until steady condition reached. Ambient 22.0
o
Un (V) 
In (A)  
Pn (W) 
Pout (W) 
90 0.220  11.8  N.A. 
100 0.201  11.8  N.A. 
240 0.113  12.1  N.A. 
264 0.107  12.3  N.A. 
 
 
Loudspeaker impedance (Ω) ..................................: -- 
— 
 
Several loudspeaker systems 
-- 
N.A. 
 
Marking of loudspeaker terminals 
-- 
N.A. 
Monitored point: 
dT (K)               
264V / 90V 
Limit dT (K) 
PCB near U4 
52.8 / 53.6 
75 
PCB near U308 
22.9 / 23.3 
75 
Fuse holder 
13.0 / 13.5 
30 (65-35) 
Winding of L512 
14.8 / 19.6 
65* 
C502 (X2 capacitor ) 
13.9 / 15.1 
50 (85-35) 
EC502 (electrolytic capacitor) 
16.3 / 15.9 
70 (105-35) 
CY502 (Y1 capacitor)  
12.7 / 13.1 
50 (85-35)
 
C503 (X2 capacitor ) 
14.8 / 15.1 
50 (85-35) 
Heatsink of U503 
22.9 / 18.2 
75 
Winding of T502 
21.5 / 20.1 
65* 
PCB near T502 
23.3 / 22.9 
75 
Bobbin of T502 
21.8 / 20.3 
65 
PCB near D518 
19.7 / 19.8 
75 
EC520 (electrolytic capacitor) 
19.5 / 19.3 
70 (105-35) 
CY2 (Y1 capacitor)  
16.6 / 15.9 
50 (85-35)
 
Power cord 
13.9 / 12.8 
50  
Enclosure (metallic)  
10.0 / 10.3 
30 (65-35)
 
Enclosure (non-metallic) 
8.2 / 9.3 
50 
Page of 65