Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate ▷ View online
page 35 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
4.2.4
- Revision to sub-clause a): Minimum audio output
is not less than 0.5 W per channel unless the
maximum audio output is less than 0.5 W per
channel.
is not less than 0.5 W per channel unless the
maximum audio output is less than 0.5 W per
channel.
Noted
4.2.4.1
- Add: “An apparatus with multiple modes of
operation, multiple signal input sources, or both, is
to be operated using each mode of operation or
signal input source separately, or in combination,
according to the manufacturer’s instructions to
produce the maximum power input”.
Table 2: External supply sources are assumed to
be capable of delivering 30 A, unless otherwise
specified (no-load voltage and internal resistance
values in the Table are modified).
operation, multiple signal input sources, or both, is
to be operated using each mode of operation or
signal input source separately, or in combination,
according to the manufacturer’s instructions to
produce the maximum power input”.
Table 2: External supply sources are assumed to
be capable of delivering 30 A, unless otherwise
specified (no-load voltage and internal resistance
values in the Table are modified).
Noted
4.3.4
- Add: PTC thermistors may also comply with UL
1434.
1434.
Noted
5.1
- Add: Component power supplies and adapters
complying with the construction and test
requirements of UL 1310, UL 1950, or UL 60950
fulfill the requirements of items “a” through “i” of
this clause.
complying with the construction and test
requirements of UL 1310, UL 1950, or UL 60950
fulfill the requirements of items “a” through “i” of
this clause.
Noted
5.1f
- Add: Rated frequency is required on all
apparatus
apparatus
50/60 Hz
Pass
5.1g
- Add: Rated current or power required on all
apparatus.
apparatus.
20W Pass
5.1j
- Add: Date of Manufacture” marking required on
all apparatus.
all apparatus.
Pass
5.1k
- Add: Manufacturing identification marking
required.
required.
N/A
5.1l
- Add: Combination of two graphical symbols and
supplementary marking is required.
supplementary marking is required.
Printed on the rear enclosure
Pass
5.1m
- Add: Equipment rack marking required for
audio/video systems.
audio/video systems.
N/A
5.1n
- Add: Units having leakage current levels greater
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high leakage current
marking.
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high leakage current
marking.
N/A
5.2c
- Modification: Output terminals must be marked
with voltage, frequency and current or power;
output terminals installed or interconnected in the
field must be marked with the class of wiring.
with voltage, frequency and current or power;
output terminals installed or interconnected in the
field must be marked with the class of wiring.
N/A
5.2d
- Add: Audio output connections shall be marked
“Class 1 Wiring”, “Class 2 Wiring” or “Class 3
Wiring”.
Operation manual shall discuss risks and proper
connecting and insulating techniques when
connecting a speaker.
“Class 1 Wiring”, “Class 2 Wiring” or “Class 3
Wiring”.
Operation manual shall discuss risks and proper
connecting and insulating techniques when
connecting a speaker.
N/A
5.3
- Add: "An explanation and illustration of safety
related graphical symbols used on the apparatus
shall be included in the owner’s instructions
preceding any operating instructions.”
related graphical symbols used on the apparatus
shall be included in the owner’s instructions
preceding any operating instructions.”
Pass
page 36 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
5.4
- Add: Important Safety Instructions are to be
packed with each apparatus and shall be
verbatim.
packed with each apparatus and shall be
verbatim.
Pass
5.4.1
- Add: Warning about Outdoor Use is required.
Noted
5.4.3
- Add: When apparatus contains instructions for
use by service personnel the instructions are
separate in format and preceded by a
precautionary warning statement.
use by service personnel the instructions are
separate in format and preceded by a
precautionary warning statement.
N/A
6.1
- Starting from second paragraph replace all by:
"Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by
measuring the radiation produced by the
apparatus employing a design center chassis."
"Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by
measuring the radiation produced by the
apparatus employing a design center chassis."
N/A
6.2
- Starting from second paragraph replace all by:
"Apparatus shall be classified and labeled in
accordance with the Code of Federal Regulations,
Title 21, Chapter 1, Subchapter J, Sections
1010.2, 1010.3, 1040.10 and 1040.11."
"Apparatus shall be classified and labeled in
accordance with the Code of Federal Regulations,
Title 21, Chapter 1, Subchapter J, Sections
1010.2, 1010.3, 1040.10 and 1040.11."
Pass
6.2.2
- Deleted
Noted
7.1
Table 3: Temperature limits added for various
classes of insulation systems.
Add to Note a): "Materials rated in accordance
with UL 746B may be used at their rated higher
temperature."
classes of insulation systems.
Add to Note a): "Materials rated in accordance
with UL 746B may be used at their rated higher
temperature."
Noted
7.2
– Add: A material
temperature rating can be accepted in lieu of the
softening temperature. The softening
test need not be performed on materials used in
UL Listed or Recognized parts.
temperature rating can be accepted in lieu of the
softening temperature. The softening
test need not be performed on materials used in
UL Listed or Recognized parts.
Noted
8.1
- Add: “A metal part that is not inherently resistant
to corrosion shall be protected against corrosion
when corrosion of that part is capable of
contributing to or resulting in a risk of fire, shock,
or injury to persons.”
to corrosion shall be protected against corrosion
when corrosion of that part is capable of
contributing to or resulting in a risk of fire, shock,
or injury to persons.”
Noted
8.9.1
- Add: “Sleeving, tape, tubing, and wire insulation
are suitable for the conditions of use, such as
voltage and temperature, and comply with UL 224,
UL 510, and UL 1441, as applicable.”
are suitable for the conditions of use, such as
voltage and temperature, and comply with UL 224,
UL 510, and UL 1441, as applicable.”
Pass
8.10
- Add: “Component power supplies and their
internal insulation complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
internal insulation complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
Noted
8.12
- Modification: Conductors and internal wiring
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based
on the marked rating of the outlet but shall not be
less than 18 AWG.
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based
on the marked rating of the outlet but shall not be
less than 18 AWG.
18 AWG
Pass
page 37 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
8.17
- Add: As an option, winding wire insulation may
comply with the requirements in UL Subject 2353.
comply with the requirements in UL Subject 2353.
N/A
8.19.1
- Modification: An all-pole switch or circuit breaker
is not required to have contact separation of 3
mm.
is not required to have contact separation of 3
mm.
No such parts
N/A
8.22
- Add: “Printed wiring boards involved with the risk
of electric shock shall comply with the
requirements in UL 796.”
of electric shock shall comply with the
requirements in UL 796.”
Pass
9.1.1.1
- Replace: For Class I apparatus the r.m.s.
TOUCH-CURRENT to earth shall not be more
than 3.5 MIU.
TOUCH-CURRENT to earth shall not be more
than 3.5 MIU.
Class II construction
N/A
9.1.1.1a
- 2nd dash replaced by: “For audio signals of
professional and commercial apparatus, 120 V
r.m.s.”
3rd dash replaced by: “For audio signals other
than professional and commercial apparatus, 71 V
r.m.s.”
professional and commercial apparatus, 120 V
r.m.s.”
3rd dash replaced by: “For audio signals other
than professional and commercial apparatus, 71 V
r.m.s.”
Pass
9.1.1.1b
- Modification: Touch current shall comply with the
American National Standard for Leakage Current
for Appliances, ANSI C101 and not exceed 0.5
MIU for Class ll Delete Note 2.
American National Standard for Leakage Current
for Appliances, ANSI C101 and not exceed 0.5
MIU for Class ll Delete Note 2.
0.23MIU Pass
9.1.1.2
- UL articulated finger replaces IEC 61032 test
probe B. Delete 3rd paragraph.
Table 5 - Add Note 1: “With respect to mains
voltages in the range of 105-130 V (r.m.s.), the
test voltages are considered to be 1414 V peak for
basic and supplementary insulation and 2828 V
peak for reinforced insulation.”
probe B. Delete 3rd paragraph.
Table 5 - Add Note 1: “With respect to mains
voltages in the range of 105-130 V (r.m.s.), the
test voltages are considered to be 1414 V peak for
basic and supplementary insulation and 2828 V
peak for reinforced insulation.”
Pass
11
- Add: “Component power supplies and their
power transformers complying with the
construction and test requirements of UL 1310, UL
1950 Third Edition, or UL 60950 are considered to
fulfill the test requirements on the clause.”
power transformers complying with the
construction and test requirements of UL 1310, UL
1950 Third Edition, or UL 60950 are considered to
fulfill the test requirements on the clause.”
Noted
11.1
- Modification: The permissible touch current for
terminal contacts has been increased to twice the
value given in 9.1.1.1.
terminal contacts has been increased to twice the
value given in 9.1.1.1.
Noted
11.2.1
- Modification: Additional fuse testing not required
if the temperature is limited by fuses.
if the temperature is limited by fuses.
N/A
12
- Add: “Component power supply adaptors and
their enclosures complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
their enclosures complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
Noted
12.1.3
- Delete the first two paragraphs. Impact test uses
the 50mm steel sphere only.
Table 6 – Replace title with “Apparatus impact
test.” Table 6 modified to provide impact test
criteria detailing impact location, impact energy
and additional pass/fail results.”
the 50mm steel sphere only.
Table 6 – Replace title with “Apparatus impact
test.” Table 6 modified to provide impact test
criteria detailing impact location, impact energy
and additional pass/fail results.”
2.0J Pass
page 38 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
12.1.4
- Add to the end of the 1st paragraph: “As an
alternative, any number form one to three samples
are permitted to be used in any combination that
results in a total of three drops.”
alternative, any number form one to three samples
are permitted to be used in any combination that
results in a total of three drops.”
Noted
12.1.6
- Add: Handle strength test requirements.
No such parts.
N/A
12.7
- Add: Wall and ceiling mounting means test
requirements.
requirements.
No such function
N/A
12.8
- Add test for enclosures, barriers, components
and leads that rely on adhesive.
and leads that rely on adhesive.
N/A
12.8.1
- Add test for conductive labels secured in place
by adhesive.
by adhesive.
No such parts.
N/A
13
- Add: ”Component power supplies and their
power transformers complying with the
construction and test requirements of UL 1310, UL
1950 Third Edition, or UL 60950 are considered to
fulfill the test requirements
on the clause.”
power transformers complying with the
construction and test requirements of UL 1310, UL
1950 Third Edition, or UL 60950 are considered to
fulfill the test requirements
on the clause.”
Noted
13.4
- Modification: A material group is verified
according to UL 746A.
according to UL 746A.
Pass
13.5.1
- Change standard reference from IEC 60249-2 to
UL 796.
UL 796.
Noted
13.5.2
- Modification: Coated printed wiring boards shall
comply with requirements in UL 746C
Table 12 - Note 3 revised to refer to UL 746A.
comply with requirements in UL 746C
Table 12 - Note 3 revised to refer to UL 746A.
Noted
14
- Delete Note 2. Add reference to Annex Y and
additional component requirements.
14.1, 14.2 and 14.3 – Add: ”Component power
supplies and their resistors complying with the
construction and test requirements of UL 1310, UL
1950 Third Edition, or UL 60950 are considered to
fulfill the test requirements of Clause 14.1 and
14.2.1 – 14.5.2..
additional component requirements.
14.1, 14.2 and 14.3 – Add: ”Component power
supplies and their resistors complying with the
construction and test requirements of UL 1310, UL
1950 Third Edition, or UL 60950 are considered to
fulfill the test requirements of Clause 14.1 and
14.2.1 – 14.5.2..
Noted
14.2.1 and 14.2.2 - Add: “As an alternative a
component such as a capacitor, a combination
capacitor and resistor, a varistor, or a suppressor
shall comply with the requirements for Across-the
Line, Antenna-Coupling, or Double Protection in
UL 1414.”
component such as a capacitor, a combination
capacitor and resistor, a varistor, or a suppressor
shall comply with the requirements for Across-the
Line, Antenna-Coupling, or Double Protection in
UL 1414.”
Noted
14.2.4
- Replace text with: “Components subjected to the
requirements in 14.2.1 and 14.2.2 shall also
comply with the enclosure requirements of UL
1414.”
requirements in 14.2.1 and 14.2.2 shall also
comply with the enclosure requirements of UL
1414.”
Noted