DOWNLOAD Harman Kardon DVD 23 (serv.man11) Service Manual ↓ Size: 2.88 MB | Pages: 65 in PDF or view online for FREE

Model
DVD 23 (serv.man11)
Pages
65
Size
2.88 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dvd-23-sm11.pdf
Date

Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate ▷ View online

 
 
page 35 of  63 
Ref. No. : JSH05110330-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
4.2.4 
- Revision to sub-clause a): Minimum audio output 
is not less than 0.5 W per channel unless the 
maximum audio output is less than 0.5 W per 
channel. 
 Noted 
4.2.4.1 
- Add: “An apparatus with multiple modes of 
operation, multiple signal input sources, or both, is 
to be operated using each mode of operation or 
signal input source separately, or in combination, 
according to the manufacturer’s instructions to 
produce the maximum power input”. 
Table 2: External supply sources are assumed to 
be capable of delivering 30 A, unless otherwise 
specified (no-load voltage and internal resistance 
values in the Table are modified). 
 Noted 
4.3.4 
- Add: PTC thermistors may also comply with UL 
1434. 
 Noted 
5.1 
- Add: Component power supplies and adapters 
complying with the construction and test 
requirements of UL 1310, UL 1950, or UL 60950 
fulfill the requirements of items “a” through “i” of 
this clause. 
 Noted 
5.1f 
- Add: Rated frequency is required on all 
apparatus 
50/60 Hz 
Pass 
5.1g 
- Add: Rated current or power required on all 
apparatus. 
20W Pass 
5.1j 
- Add: Date of Manufacture” marking required on 
all apparatus. 
 Pass 
5.1k 
- Add: Manufacturing identification marking 
required. 
 N/A 
5.1l 
- Add: Combination of two graphical symbols and 
supplementary marking is required. 
Printed on the rear enclosure 
Pass 
5.1m 
- Add: Equipment rack marking required for 
audio/video systems. 
 N/A 
5.1n 
- Add: Units having leakage current levels greater 
than 0.75 MIU and equal to or less than 3.5 MIU 
must be marked with a high leakage current 
marking. 
 N/A 
5.2c 
- Modification: Output terminals must be marked 
with voltage, frequency and current or power; 
output terminals installed or interconnected in the 
field must be marked with the class of wiring. 
 N/A 
5.2d 
- Add: Audio output connections shall be marked 
“Class 1 Wiring”, “Class 2 Wiring” or “Class 3 
Wiring”. 
Operation manual shall discuss risks and proper 
connecting and insulating techniques when 
connecting a speaker. 
 N/A 
5.3 
- Add: "An explanation and illustration of safety 
related graphical symbols used on the apparatus 
shall be included in the owner’s instructions 
preceding any operating instructions.” 
 Pass 
 
 
page 36 of  63 
Ref. No. : JSH05110330-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
5.4 
- Add: Important Safety Instructions are to be 
packed with each apparatus and shall be 
verbatim. 
 Pass 
5.4.1 
- Add: Warning about Outdoor Use is required. 
 Noted 
5.4.3 
- Add: When apparatus contains instructions for 
use by service personnel the instructions are 
separate in format and preceded by a 
precautionary warning statement. 
 N/A 
6.1 
- Starting from second paragraph replace all by: 
"Compliance is checked in accordance with the 
requirements in the U.S. Code of Federal 
Regulations, Title 21, Chapter 1, Subchapter J, 
Sections 1010.2, 1010.3, and 1020.10 by 
measuring the radiation produced by the 
apparatus employing a design center chassis." 
 N/A 
6.2 
- Starting from second paragraph replace all by: 
"Apparatus shall be classified and labeled in 
accordance with the Code of Federal Regulations, 
Title 21, Chapter 1, Subchapter J, Sections 
1010.2, 1010.3, 1040.10 and 1040.11." 
 Pass 
6.2.2 
- Deleted 
 
Noted 
7.1 
Table 3: Temperature limits added for various 
classes of insulation systems. 
Add to Note a): "Materials rated in accordance 
with UL 746B may be used at their rated higher 
temperature." 
 Noted 
7.2 
– Add: A material 
temperature rating can be accepted in lieu of the 
softening temperature. The softening 
test need not be performed on materials used in 
UL Listed or Recognized parts. 
 Noted 
8.1 
- Add: “A metal part that is not inherently resistant 
to corrosion shall be protected against corrosion 
when corrosion of that part is capable of 
contributing to or resulting in a risk of fire, shock, 
or injury to persons.” 
 Noted 
8.9.1 
- Add: “Sleeving, tape, tubing, and wire insulation 
are suitable for the conditions of use, such as 
voltage and temperature, and comply with UL 224, 
UL 510, and UL 1441, as applicable.” 
 Pass 
8.10 
- Add: “Component power supplies and their 
internal insulation complying with the construction 
and test requirements of UL 1310, UL 1950 Third 
Edition, or UL 60950 are considered to fulfill the 
test requirements on the clause.” 
 Noted 
8.12 
- Modification: Conductors and internal wiring 
connecting mains socket-outlets shall comply with 
the wire size requirements in clause 16.2 based 
on the marked rating of the outlet but shall not be 
less than 18 AWG. 
18 AWG 
Pass 
 
 
page 37 of  63 
Ref. No. : JSH05110330-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
8.17 
- Add: As an option, winding wire insulation may 
comply with the requirements in UL Subject 2353. 
 N/A 
8.19.1 
- Modification: An all-pole switch or circuit breaker 
is not required to have contact separation of 3 
mm. 
No such parts 
N/A 
8.22 
- Add: “Printed wiring boards involved with the risk 
of electric shock shall comply with the 
requirements in UL 796.” 
 Pass 
9.1.1.1 
- Replace: For Class I apparatus the r.m.s. 
TOUCH-CURRENT to earth shall not be more 
than 3.5 MIU. 
Class II construction 
N/A 
9.1.1.1a 
- 2nd dash replaced by: “For audio signals of 
professional and commercial apparatus, 120 V 
r.m.s.” 
3rd dash replaced by: “For audio signals other 
than professional and commercial apparatus, 71 V 
r.m.s.” 
 Pass 
9.1.1.1b 
- Modification: Touch current shall comply with the 
American National Standard for Leakage Current 
for Appliances, ANSI C101 and not exceed 0.5 
MIU for Class ll Delete Note 2. 
0.23MIU Pass 
9.1.1.2 
- UL articulated finger replaces IEC 61032 test 
probe B. Delete 3rd paragraph. 
Table 5 - Add Note 1: “With respect to mains 
voltages in the range of 105-130 V (r.m.s.), the 
test voltages are considered to be 1414 V peak for 
basic and supplementary insulation and 2828 V 
peak for reinforced insulation.” 
 
Pass 
11 
- Add: “Component power supplies and their 
power transformers complying with the 
construction and test requirements of UL 1310, UL 
1950 Third Edition, or UL 60950 are considered to 
fulfill the test requirements on the clause.” 
 Noted 
 
11.1 
- Modification: The permissible touch current for 
terminal contacts has been increased to twice the 
value given in 9.1.1.1. 
 Noted 
11.2.1 
- Modification: Additional fuse testing not required 
if the temperature is limited by fuses. 
 N/A 
12 
- Add: “Component power supply adaptors and 
their enclosures complying with the construction 
and test requirements of UL 1310, UL 1950 Third 
Edition, or UL 60950 are considered to fulfill the 
test requirements on the clause.” 
 Noted 
 
12.1.3 
- Delete the first two paragraphs. Impact test uses 
the 50mm steel sphere only. 
Table 6 – Replace title with “Apparatus impact 
test.” Table 6 modified to provide impact test 
criteria detailing impact location, impact energy 
and additional pass/fail results.” 
2.0J Pass 
 
 
page 38 of  63 
Ref. No. : JSH05110330-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
12.1.4 
- Add to the end of the 1st paragraph: “As an 
alternative, any number form one to three samples 
are permitted to be used in any combination that 
results in a total of three drops.” 
 Noted 
 
12.1.6 
- Add: Handle strength test requirements. 
No such parts. 
N/A 
 
12.7 
- Add: Wall and ceiling mounting means test 
requirements. 
No such function 
N/A 
 
12.8 
- Add test for enclosures, barriers, components 
and leads that rely on adhesive. 
 N/A 
 
12.8.1 
- Add test for conductive labels secured in place 
by adhesive. 
No such parts. 
N/A 
 
13 
- Add: ”Component power supplies and their 
power transformers complying with the 
construction and test requirements of UL 1310, UL 
1950 Third Edition, or UL 60950 are considered to 
fulfill the test requirements 
on the clause.” 
 Noted 
 
13.4 
- Modification: A material group is verified 
according to UL 746A. 
 Pass 
 
13.5.1 
- Change standard reference from IEC 60249-2 to 
UL 796. 
 Noted 
13.5.2 
- Modification: Coated printed wiring boards shall 
comply with requirements in UL 746C 
Table 12 - Note 3 revised to refer to UL 746A. 
 Noted 
 
14 
- Delete Note 2. Add reference to Annex Y and 
additional component requirements. 
14.1, 14.2 and 14.3 – Add: ”Component power 
supplies and their resistors complying with the 
construction and test requirements of UL 1310, UL 
1950 Third Edition, or UL 60950 are considered to 
fulfill the test requirements of Clause 14.1 and 
14.2.1 – 14.5.2..                      
 Noted 
 
14.2.1 and 14.2.2 - Add: “As an alternative a 
component such as a capacitor, a combination 
capacitor and resistor, a varistor, or a suppressor 
shall comply with the requirements for Across-the 
Line, Antenna-Coupling, or Double Protection in 
UL 1414.” 
 Noted 
14.2.4 
- Replace text with: “Components subjected to the 
requirements in 14.2.1 and 14.2.2 shall also 
comply with the enclosure requirements of UL 
1414.” 
 Noted 
 
Page of 65