page 43 of  63 
Ref. No. : JSH05110330-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
18.1 
- All tubes shall be mounted such that the 
enclosure of the apparatus protects the tube 
against the effects of implosion. Delete reference 
to clause 18.2. 
18.2, 18.2.1, and 18.2.3 are deleted..19  
- Add reference to 19.2.1. The test of 19.3 is 
conducted on 1) apparatus with direct view CRT 
with 48 cm diagonal min., 2) apparatus, other than 
a speaker, with a mass greater than 47 kg, and 3) 
apparatus, other than a speaker, with a mass or 
25 kg or greater and a height of 1 m or more. The 
tests in 19.1, 19.2 and 19.3 shall not cause the 
apparatus to overturn. During the test of 19.2.1, 
the apparatus shall not slide. 
 
N/A 
19.2.1 
- Add: Slide test requirements. 
 
N/A 
19.3 
- Replace by Horizontal force stability test 
requirements. 
 N/A 
Table 20 
- Add values for horizontal force test 
 N/A 
19.6 
- Add: “or equipment rack mounting”. 
 N/A 
20.1a 
- Delete 
 Noted 
20.1b 
- Replace “IEC 60707” with “UL 94” 
Add: “-parts such as protection TV lenses, 
loudspeaker parts, external accessories, and 
fibrous materials less than 0.25 mm thick.” 
 N/A 
20.1.2 
- Revise text to read: “Sleeving, extruded tubing 
and insulation on wiring shall be rated VW-1 under 
following conditions: a) wiring located in a circuit 
that is considered a potential ignition source” or b) 
wiring not located in a circuit that is a potential 
ignition source but is in contact with wiring located 
in a circuit that is a potential ignition source. ”Tape 
should be flame retardant.”    
Delete Note and add: “Tape in contact with parts 
of circuits that are potential ignition sources shall 
be flame retardant. 
 N/A 
20.1.3 
- Replace 1st paragraph with: “Base material of 
printed wiring boards, on which the available 
power as the connection exceeds 15 W or the 
operating voltage exceeds 50 V a.c. or d.c under 
normal operating conditions, shall be of 
flammability category V-1 or better according to 
UL 94.” 
In 2nd paragraph replace “IEC 60707” with “UL 
94” and remove exception for printed boards 
housed in metal enclosures. 
In 3rd paragraph replace “IEC 60707” with “UL 94” 
and delete option to use Clause G.1 of Annex G. 
 Pass 
 
 
page 44 of  63 
Ref. No. : JSH05110330-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
20.1.4 
- Replace with: “Components and parts shall 
comply with the relevant flammability category 
according to UL 94 as specified in Table 21. 
Delete all other text. 
 
Pass 
20.1.4 
- Add: “Component power supplies complying with 
the construction and test requirements of UL 1310, 
UL 1950 Third Edition, or UL 60950 are 
considered to fulfill the test requirements on the 
clause.” 
Table 21 - Replace complete table with new table 
for “Flammability categories for components and 
parts.” 
See components list 
Pass 
20.2.1 
- Modification: 1st paragraph: “Fire enclosure 
required for 1) circuits and components where the 
available power exceeds 15 W, 2) inductors and 
windings conductively connected to the mains and 
3) high-voltage products. The fire enclosure shall 
comply with the flammability  requirements of 
Table 22 according to UL 94 and 746C. 2nd, 3rd, 
and 4th paragraphs are deleted. 
In 5th paragraph replace “IEC 60707 or clause G.1 
of Annex G” with “UL 94 or UL 746C.” 
Table 22 – Add” Flammability categories for fire 
enclosures. 
 N/A
 
20.2.2 
- Revise text to read: “Internal fire enclosures shall 
not have openings that permit accessibility to 
components, wiring, connections, or printed wiring 
board conductive patterns where the available 
power exceeds 15 W and to inductors and 
windings conductively connected to the mains and 
shall comply with the material requirements in 
Table 22. Compliance is checked by inspection 
and measurement and using the jointed test 
finger.” 
 N/A 
20.2.3 
- Modification: Outer enclosures shall have a 
minimum flammability rating of HB, per UL 94, 
when an internal fire enclosure is provided. 
Modifications to Figures: 
Fig 14 - Illustrates the articulated finger probe. 
Fig 15 - Illustrates the shock hazard marking and 
associated graphical symbols. 
Fig 16 - Illustrates the shock hazard graphical 
symbol. 
Fig 17 - Illustrates portable cart marking. 
Fig 18 - High voltage spacings graph. 
Fig 19 - Class 105 insulation aging temperature 
graph. 
Fig 20 - Flowchart for horizontal force test. 
 N/A 
 
 
page 45 of  63 
Ref. No. : JSH05110330-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
Annex A 
- Modification: Apparatus intended for outdoor use 
or wet locations has any of the following attributes: 
a) provided with a means to make it transportable, 
b) has a mass less than 35 kg, c) can be battery 
operated, d) associated literature states or implies 
such use 
 Noted 
 
Add: Apparatus in a), b), or c) above is not 
considered for outdoor use or in wet locations if 
marked as specified in 5.4..A.5, A.5.1 and A.5.4.1 
are deleted. 
A.9.1.1 - Add: Touch current test shall be 
conducted after the water spray test described in 
A.11.1.1 and the touch current shall not be more 
than 0.5 MIU when the open-circuit potential 
between any accessible part and earth or any 
other accessible part is more than 21.2 V peak. 
A.10, A10.2, A.10.2.1, and A.10.2.2 are deleted. 
A.11.1.1 - Add: Apparatus shall be subjected to 
the water spray test according to UL 1571. 
A.16.1 - Add: Flexible cords shall be suitable for 
outdoor use. 
A.20.2.1 - Add: Enclosures for an apparatus 
intended for permanent outdoor location shall 
comply with requirements for Type 3 enclosures in 
UL 50. 
 Noted 
Annex B 
  
5th paragraph - add reference to clause 4.2.1.1 in 
IEC 62151. 
Add to 12th paragraph: “The requirements of 
4.2.1.1 shall be replaced by the requirements or 
2.3.1 of UL 60950, Third Edition.” 
 Noted 
 
13th paragraph, 2nd dash replace with: “In the 
event of a single insulation fault, the voltages on 
the TNV-0 circuits, TNV-1 circuits and accessible 
conductive parts shall not exceed the values given 
in clause 9.1.1.1a of this standard for more than 
0.2 s. Moreover, the limits values as given in 11.1 
shall not be exceeded. After 0.2 s the voltage 
limits of 4.1.2 (35 V peak, or 60 V d.c.) shall 
apply.” 
 Noted 
 
Add to 19th paragraph: “Apparatus intended to be 
connected to telecommunication networks and 
having ringing voltages applied to the apparatus is 
subjected to touch current limits in accordance 
with clause 
 
Noted 
 
 
page 46 of  63 
Ref. No. : JSH05110330-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
5.1.8.1.1 
of UL 60950, Third Edition” Add to 21st paragraph: 
“Telecommunication network that uses outside 
cable shall comply with the requirements for 
protection against overvoltage from power line 
crosses per 6.4 of UL 60950, Third Edition” 
Add to 22nd paragraph: “Acoustic tests per 6.5 of 
UL 60950, Third Edition for apparatus containing 
earphone held against the ear.” 
Add to 24th paragraph: “Apparatus shall be 
provided with appropriate markings and 
instructions as described in Annex NAA of UL 
60950, Third Edition.” 
Annex D - Figure D.1 & Note delete reference to 
IEC 60990 and add reference to ANSI C101. Add 
touch current value in MIU where MIU = U2 x 2 
(r.m.s. value) 
Annex G - Deleted 
Annex Q - Add: Safety requirements for video 
apparatus for use in health care facilities 
Annex R - Add: Safety requirements for 
undercabinet apparatus 
Annex S - Add: Safety requirements for in-wall 
mounted apparatus 
Annex T - Add: Safety requirements for apparatus 
with projection lamps 
Annex U - Add: Safety requirements for 
permanently connected apparatus 
Annex V - Add: Safety requirements for carts, 
stands, and similar apparatus for use with specific 
apparatus covered by this standard 
Annex W - Add: Construction details for a 0.02-
ohm shunt for use in the peak inrush-current 
measurement described in 14.6.11.1 
Annex X - Add: Manufacturing and production-line 
tests 
Annex Y - Add: Normative standards for 
components. 
 Noted 
 
 
 
 
 
 
 