Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate ▷ View online
page 43 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
18.1
- All tubes shall be mounted such that the
enclosure of the apparatus protects the tube
against the effects of implosion. Delete reference
to clause 18.2.
18.2, 18.2.1, and 18.2.3 are deleted..19
- Add reference to 19.2.1. The test of 19.3 is
conducted on 1) apparatus with direct view CRT
with 48 cm diagonal min., 2) apparatus, other than
a speaker, with a mass greater than 47 kg, and 3)
apparatus, other than a speaker, with a mass or
25 kg or greater and a height of 1 m or more. The
tests in 19.1, 19.2 and 19.3 shall not cause the
apparatus to overturn. During the test of 19.2.1,
the apparatus shall not slide.
enclosure of the apparatus protects the tube
against the effects of implosion. Delete reference
to clause 18.2.
18.2, 18.2.1, and 18.2.3 are deleted..19
- Add reference to 19.2.1. The test of 19.3 is
conducted on 1) apparatus with direct view CRT
with 48 cm diagonal min., 2) apparatus, other than
a speaker, with a mass greater than 47 kg, and 3)
apparatus, other than a speaker, with a mass or
25 kg or greater and a height of 1 m or more. The
tests in 19.1, 19.2 and 19.3 shall not cause the
apparatus to overturn. During the test of 19.2.1,
the apparatus shall not slide.
N/A
19.2.1
- Add: Slide test requirements.
N/A
19.3
- Replace by Horizontal force stability test
requirements.
requirements.
N/A
Table 20
- Add values for horizontal force test
N/A
19.6
- Add: “or equipment rack mounting”.
N/A
20.1a
- Delete
Noted
20.1b
- Replace “IEC 60707” with “UL 94”
Add: “-parts such as protection TV lenses,
loudspeaker parts, external accessories, and
fibrous materials less than 0.25 mm thick.”
Add: “-parts such as protection TV lenses,
loudspeaker parts, external accessories, and
fibrous materials less than 0.25 mm thick.”
N/A
20.1.2
- Revise text to read: “Sleeving, extruded tubing
and insulation on wiring shall be rated VW-1 under
following conditions: a) wiring located in a circuit
that is considered a potential ignition source” or b)
wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source. ”Tape
should be flame retardant.”
Delete Note and add: “Tape in contact with parts
of circuits that are potential ignition sources shall
be flame retardant.
and insulation on wiring shall be rated VW-1 under
following conditions: a) wiring located in a circuit
that is considered a potential ignition source” or b)
wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source. ”Tape
should be flame retardant.”
Delete Note and add: “Tape in contact with parts
of circuits that are potential ignition sources shall
be flame retardant.
N/A
20.1.3
- Replace 1st paragraph with: “Base material of
printed wiring boards, on which the available
power as the connection exceeds 15 W or the
operating voltage exceeds 50 V a.c. or d.c under
normal operating conditions, shall be of
flammability category V-1 or better according to
UL 94.”
In 2nd paragraph replace “IEC 60707” with “UL
94” and remove exception for printed boards
housed in metal enclosures.
In 3rd paragraph replace “IEC 60707” with “UL 94”
and delete option to use Clause G.1 of Annex G.
printed wiring boards, on which the available
power as the connection exceeds 15 W or the
operating voltage exceeds 50 V a.c. or d.c under
normal operating conditions, shall be of
flammability category V-1 or better according to
UL 94.”
In 2nd paragraph replace “IEC 60707” with “UL
94” and remove exception for printed boards
housed in metal enclosures.
In 3rd paragraph replace “IEC 60707” with “UL 94”
and delete option to use Clause G.1 of Annex G.
Pass
page 44 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
20.1.4
- Replace with: “Components and parts shall
comply with the relevant flammability category
according to UL 94 as specified in Table 21.
Delete all other text.
comply with the relevant flammability category
according to UL 94 as specified in Table 21.
Delete all other text.
Pass
20.1.4
- Add: “Component power supplies complying with
the construction and test requirements of UL 1310,
UL 1950 Third Edition, or UL 60950 are
considered to fulfill the test requirements on the
clause.”
Table 21 - Replace complete table with new table
for “Flammability categories for components and
parts.”
the construction and test requirements of UL 1310,
UL 1950 Third Edition, or UL 60950 are
considered to fulfill the test requirements on the
clause.”
Table 21 - Replace complete table with new table
for “Flammability categories for components and
parts.”
See components list
Pass
20.2.1
- Modification: 1st paragraph: “Fire enclosure
required for 1) circuits and components where the
available power exceeds 15 W, 2) inductors and
windings conductively connected to the mains and
3) high-voltage products. The fire enclosure shall
comply with the flammability requirements of
Table 22 according to UL 94 and 746C. 2nd, 3rd,
and 4th paragraphs are deleted.
In 5th paragraph replace “IEC 60707 or clause G.1
of Annex G” with “UL 94 or UL 746C.”
Table 22 – Add” Flammability categories for fire
enclosures.
required for 1) circuits and components where the
available power exceeds 15 W, 2) inductors and
windings conductively connected to the mains and
3) high-voltage products. The fire enclosure shall
comply with the flammability requirements of
Table 22 according to UL 94 and 746C. 2nd, 3rd,
and 4th paragraphs are deleted.
In 5th paragraph replace “IEC 60707 or clause G.1
of Annex G” with “UL 94 or UL 746C.”
Table 22 – Add” Flammability categories for fire
enclosures.
N/A
20.2.2
- Revise text to read: “Internal fire enclosures shall
not have openings that permit accessibility to
components, wiring, connections, or printed wiring
board conductive patterns where the available
power exceeds 15 W and to inductors and
windings conductively connected to the mains and
shall comply with the material requirements in
Table 22. Compliance is checked by inspection
and measurement and using the jointed test
finger.”
not have openings that permit accessibility to
components, wiring, connections, or printed wiring
board conductive patterns where the available
power exceeds 15 W and to inductors and
windings conductively connected to the mains and
shall comply with the material requirements in
Table 22. Compliance is checked by inspection
and measurement and using the jointed test
finger.”
N/A
20.2.3
- Modification: Outer enclosures shall have a
minimum flammability rating of HB, per UL 94,
when an internal fire enclosure is provided.
Modifications to Figures:
Fig 14 - Illustrates the articulated finger probe.
Fig 15 - Illustrates the shock hazard marking and
associated graphical symbols.
Fig 16 - Illustrates the shock hazard graphical
symbol.
Fig 17 - Illustrates portable cart marking.
Fig 18 - High voltage spacings graph.
Fig 19 - Class 105 insulation aging temperature
graph.
Fig 20 - Flowchart for horizontal force test.
minimum flammability rating of HB, per UL 94,
when an internal fire enclosure is provided.
Modifications to Figures:
Fig 14 - Illustrates the articulated finger probe.
Fig 15 - Illustrates the shock hazard marking and
associated graphical symbols.
Fig 16 - Illustrates the shock hazard graphical
symbol.
Fig 17 - Illustrates portable cart marking.
Fig 18 - High voltage spacings graph.
Fig 19 - Class 105 insulation aging temperature
graph.
Fig 20 - Flowchart for horizontal force test.
N/A
page 45 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Annex A
- Modification: Apparatus intended for outdoor use
or wet locations has any of the following attributes:
a) provided with a means to make it transportable,
b) has a mass less than 35 kg, c) can be battery
operated, d) associated literature states or implies
such use
or wet locations has any of the following attributes:
a) provided with a means to make it transportable,
b) has a mass less than 35 kg, c) can be battery
operated, d) associated literature states or implies
such use
Noted
Add: Apparatus in a), b), or c) above is not
considered for outdoor use or in wet locations if
marked as specified in 5.4..A.5, A.5.1 and A.5.4.1
are deleted.
A.9.1.1 - Add: Touch current test shall be
conducted after the water spray test described in
A.11.1.1 and the touch current shall not be more
than 0.5 MIU when the open-circuit potential
between any accessible part and earth or any
other accessible part is more than 21.2 V peak.
A.10, A10.2, A.10.2.1, and A.10.2.2 are deleted.
A.11.1.1 - Add: Apparatus shall be subjected to
the water spray test according to UL 1571.
A.16.1 - Add: Flexible cords shall be suitable for
outdoor use.
A.20.2.1 - Add: Enclosures for an apparatus
intended for permanent outdoor location shall
comply with requirements for Type 3 enclosures in
UL 50.
considered for outdoor use or in wet locations if
marked as specified in 5.4..A.5, A.5.1 and A.5.4.1
are deleted.
A.9.1.1 - Add: Touch current test shall be
conducted after the water spray test described in
A.11.1.1 and the touch current shall not be more
than 0.5 MIU when the open-circuit potential
between any accessible part and earth or any
other accessible part is more than 21.2 V peak.
A.10, A10.2, A.10.2.1, and A.10.2.2 are deleted.
A.11.1.1 - Add: Apparatus shall be subjected to
the water spray test according to UL 1571.
A.16.1 - Add: Flexible cords shall be suitable for
outdoor use.
A.20.2.1 - Add: Enclosures for an apparatus
intended for permanent outdoor location shall
comply with requirements for Type 3 enclosures in
UL 50.
Noted
Annex B
5th paragraph - add reference to clause 4.2.1.1 in
IEC 62151.
Add to 12th paragraph: “The requirements of
4.2.1.1 shall be replaced by the requirements or
2.3.1 of UL 60950, Third Edition.”
IEC 62151.
Add to 12th paragraph: “The requirements of
4.2.1.1 shall be replaced by the requirements or
2.3.1 of UL 60950, Third Edition.”
Noted
13th paragraph, 2nd dash replace with: “In the
event of a single insulation fault, the voltages on
the TNV-0 circuits, TNV-1 circuits and accessible
conductive parts shall not exceed the values given
in clause 9.1.1.1a of this standard for more than
0.2 s. Moreover, the limits values as given in 11.1
shall not be exceeded. After 0.2 s the voltage
limits of 4.1.2 (35 V peak, or 60 V d.c.) shall
apply.”
event of a single insulation fault, the voltages on
the TNV-0 circuits, TNV-1 circuits and accessible
conductive parts shall not exceed the values given
in clause 9.1.1.1a of this standard for more than
0.2 s. Moreover, the limits values as given in 11.1
shall not be exceeded. After 0.2 s the voltage
limits of 4.1.2 (35 V peak, or 60 V d.c.) shall
apply.”
Noted
Add to 19th paragraph: “Apparatus intended to be
connected to telecommunication networks and
having ringing voltages applied to the apparatus is
subjected to touch current limits in accordance
with clause
connected to telecommunication networks and
having ringing voltages applied to the apparatus is
subjected to touch current limits in accordance
with clause
Noted
page 46 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
5.1.8.1.1
of UL 60950, Third Edition” Add to 21st paragraph:
“Telecommunication network that uses outside
cable shall comply with the requirements for
protection against overvoltage from power line
crosses per 6.4 of UL 60950, Third Edition”
Add to 22nd paragraph: “Acoustic tests per 6.5 of
UL 60950, Third Edition for apparatus containing
earphone held against the ear.”
Add to 24th paragraph: “Apparatus shall be
provided with appropriate markings and
instructions as described in Annex NAA of UL
60950, Third Edition.”
Annex D - Figure D.1 & Note delete reference to
IEC 60990 and add reference to ANSI C101. Add
touch current value in MIU where MIU = U2 x 2
(r.m.s. value)
Annex G - Deleted
Annex Q - Add: Safety requirements for video
apparatus for use in health care facilities
Annex R - Add: Safety requirements for
undercabinet apparatus
Annex S - Add: Safety requirements for in-wall
mounted apparatus
Annex T - Add: Safety requirements for apparatus
with projection lamps
Annex U - Add: Safety requirements for
permanently connected apparatus
Annex V - Add: Safety requirements for carts,
stands, and similar apparatus for use with specific
apparatus covered by this standard
Annex W - Add: Construction details for a 0.02-
ohm shunt for use in the peak inrush-current
measurement described in 14.6.11.1
Annex X - Add: Manufacturing and production-line
tests
Annex Y - Add: Normative standards for
components.
“Telecommunication network that uses outside
cable shall comply with the requirements for
protection against overvoltage from power line
crosses per 6.4 of UL 60950, Third Edition”
Add to 22nd paragraph: “Acoustic tests per 6.5 of
UL 60950, Third Edition for apparatus containing
earphone held against the ear.”
Add to 24th paragraph: “Apparatus shall be
provided with appropriate markings and
instructions as described in Annex NAA of UL
60950, Third Edition.”
Annex D - Figure D.1 & Note delete reference to
IEC 60990 and add reference to ANSI C101. Add
touch current value in MIU where MIU = U2 x 2
(r.m.s. value)
Annex G - Deleted
Annex Q - Add: Safety requirements for video
apparatus for use in health care facilities
Annex R - Add: Safety requirements for
undercabinet apparatus
Annex S - Add: Safety requirements for in-wall
mounted apparatus
Annex T - Add: Safety requirements for apparatus
with projection lamps
Annex U - Add: Safety requirements for
permanently connected apparatus
Annex V - Add: Safety requirements for carts,
stands, and similar apparatus for use with specific
apparatus covered by this standard
Annex W - Add: Construction details for a 0.02-
ohm shunt for use in the peak inrush-current
measurement described in 14.6.11.1
Annex X - Add: Manufacturing and production-line
tests
Annex Y - Add: Normative standards for
components.
Noted