Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate ▷ View online
page 39 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.4
- Add to Note 2: “High voltage materials shall be
rated 94V-2 minimum.”
Modification: Compliance is checked by meeting
requirements for category V-2 according to UL 94.
Moreover the requirements are added for arcing,
component part flame and high-voltage isolating
component tests.
rated 94V-2 minimum.”
Modification: Compliance is checked by meeting
requirements for category V-2 according to UL 94.
Moreover the requirements are added for arcing,
component part flame and high-voltage isolating
component tests.
No such parts
N/A
14.4.1
- Replace with High voltage arcing test.
N/A
14.4.2
- Deleted.
N/A
14.4.3
- Add: High voltage component part flame test.
N/A
14.4.4
- Add: High voltage isolation component insulation
test.
test.
N/A
14.5.1
- Delete reference to 14.5.1.3.
Noted
14.5.1.1
- Replace text with: Thermal cutouts shall comply
with UL 873, UL 8730-2-9 or UL 60730-2-9.
with UL 873, UL 8730-2-9 or UL 60730-2-9.
No such parts.
N/A
14.5.1.2
- Replace text with: "Thermal links shall comply
with UL 1020 or IEC 60691."
with UL 1020 or IEC 60691."
No such parts.
N/A
14.5.1.3
- Delete
Noted
14.5.2.1
- Modification: Fuse links shall comply with UL
248-14
248-14
Pass
14.5.2.2
- Delete reference to IEC 60127 and breaking
capacity marking requirements.
capacity marking requirements.
Noted
14.5.3
- Add: As an option, a PTC thermistor may comply
with UL 1434. Delete the 3rd and 4th paragraphs.
with UL 1434. Delete the 3rd and 4th paragraphs.
No such parts.
N/A
14.5.3A
- Add: Protective devices connected to the mains
shall have adequate breaking capacity and comply
with UL 873, UL 1416, UL 1417 or UL 2111 as
applicable.
shall have adequate breaking capacity and comply
with UL 873, UL 1416, UL 1417 or UL 2111 as
applicable.
No such parts.
N/A
14.5.4
- Reference to fuse-links is deleted.
Noted
14.6.1
- Add: “Switches and relays shall comply with UL
1054, UL 61058-1 or UL 508 as applicable. Mains
switch or relay shall be rated for the total current
through the switch or relay contacts.”
Replace remaining text with: “A rating of a mains
switch or relay, provided on a audio apparatus
intended for commercial use, is to be equal to or
greater than the maximum steady state current it
controls under normal operating conditions except
the audio output is adjusted to 1/3 maximum
undistorted output or at 1/3 of the manufacturer’s
rated output power, whichever is greater.”
14.6.2, 14.6.3 and 14.6.4 are deleted.
1054, UL 61058-1 or UL 508 as applicable. Mains
switch or relay shall be rated for the total current
through the switch or relay contacts.”
Replace remaining text with: “A rating of a mains
switch or relay, provided on a audio apparatus
intended for commercial use, is to be equal to or
greater than the maximum steady state current it
controls under normal operating conditions except
the audio output is adjusted to 1/3 maximum
undistorted output or at 1/3 of the manufacturer’s
rated output power, whichever is greater.”
14.6.2, 14.6.3 and 14.6.4 are deleted.
No such parts.
N/A
14.6.5
- Modification: A switch or relay that controls a
mains socket-outlet shall have a rating equal to
the rated current consumption of the apparatus
plus the current rating of the socket-outlet.
mains socket-outlet shall have a rating equal to
the rated current consumption of the apparatus
plus the current rating of the socket-outlet.
N/A
page 40 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.6.6
- Add: A mains switch shall comply with (a), (b) or
(c). The contacts of a mains relay shall comply
with (a), (b) or (d). A switch that controls a mains
receptacle shall comply with (b) and a relay that
controls a mains receptacle shall comply with (b)
or (d).
(c). The contacts of a mains relay shall comply
with (a), (b) or (d). A switch that controls a mains
receptacle shall comply with (b) and a relay that
controls a mains receptacle shall comply with (b)
or (d).
N/A
14.6.6a
- Add: Switch or relay contacts to have current
rating equal to or greater than 1.414 times the
inrush current of the apparatus.
rating equal to or greater than 1.414 times the
inrush current of the apparatus.
N/A
14.6.6b
- Add: Switch or relay to be TV rated.
N/A
14.6.6c
- Add: Switch is located on the back of apparatus
and is not operable from a remote control.
and is not operable from a remote control.
N/A
14.6.6d
- Add: Relay is to be subjected to the endurance
test.
test.
N/A
14.6.6.1
- Add: Peak Inrush current test
N/A
14.6.6.2
- Add: Relay endurance test
N/A
14.6.7
- Add: Double pole switch controlling a.c. and d.c.
circuits shall be suitable for the application.
circuits shall be suitable for the application.
N/A
14.7
- Add to the end of the 2nd paragraph “…except
that the jointed test finger to in 9.1.1 is used to
determine accessibility (IEC 60950, 2.8.2) and
interlock operation (IEC 60950, 2.8.3).”
that the jointed test finger to in 9.1.1 is used to
determine accessibility (IEC 60950, 2.8.2) and
interlock operation (IEC 60950, 2.8.3).”
No such parts.
N/A
14.10.6
- Add: “An apparatus intended for use with an
external battery shall be provided with an
overcurrent protective device in the battery-supply
circuit.”
external battery shall be provided with an
overcurrent protective device in the battery-supply
circuit.”
No such parts.
N/A
14.11
- Add: “Component power supplies and their
optocouplers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
Optocouplers bridging reinforced insulation shall
comply with requirements for double protection as
specified in UL 1577.
4th paragraph reads: “External clearances and
creepage distances of optocouplers shall comply
with 13.1.”
optocouplers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
Optocouplers bridging reinforced insulation shall
comply with requirements for double protection as
specified in UL 1577.
4th paragraph reads: “External clearances and
creepage distances of optocouplers shall comply
with 13.1.”
Pass
14.12
- Replace “IEC 61051-2” with “UL 1449” and “IEC
60707” with “UL 94.” Delete all references to “IEC
60151”.
60707” with “UL 94.” Delete all references to “IEC
60151”.
Pass
15.1.1
– Add: “Attachment plug shall have a current
rating no less than 125% of the current drawn
under normal operating conditions and a voltage
rating appropriate for the rated voltage of the
apparatus.
rating no less than 125% of the current drawn
under normal operating conditions and a voltage
rating appropriate for the rated voltage of the
apparatus.
Pass
Attachment plugs for use on more than one supply
voltage by means of a voltage selector shall be
rated for the voltage, which the apparatus is
intended to be connected when it is shipped from
the factory.
voltage by means of a voltage selector shall be
rated for the voltage, which the apparatus is
intended to be connected when it is shipped from
the factory.
N/A
page 41 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Attachment plug cap shall be polarized when the
apparatus is provided with a manually operated,
line connected, single-pole switch; Edison-base
lampholder; or a 15 or 20 A socket outlet.”
apparatus is provided with a manually operated,
line connected, single-pole switch; Edison-base
lampholder; or a 15 or 20 A socket outlet.”
N/A
15.1.2
- Delete reference to “Banana” plug in the Note.
Noted
15.1.3.1
- Add: “An audio amplifier having an open-circuit
audio output voltage not limited to 120 V that is
permanently connected to the mains shall be
provided with a means for connection complying
with U.21.1.1 –U.21.1.7 and wire-binding screws
No. 6-32 or larger complying with U.21.3.1 –
U.21.3.5, or quick-connect terminals, or leads.
Quick Connect Terminal shall comply with the
following:
a) Male tabs firmly mounted in place, b) Mating
female connectors shall be provided with the
apparatus, c) Strain Relief Test of Clause 16.5,d)
Installation instructions shall be provided for
assembly of terminal to a conductor and strain
relief, e)Terminals shall be appropriate for use with
the size and type of wire specified.”
audio output voltage not limited to 120 V that is
permanently connected to the mains shall be
provided with a means for connection complying
with U.21.1.1 –U.21.1.7 and wire-binding screws
No. 6-32 or larger complying with U.21.3.1 –
U.21.3.5, or quick-connect terminals, or leads.
Quick Connect Terminal shall comply with the
following:
a) Male tabs firmly mounted in place, b) Mating
female connectors shall be provided with the
apparatus, c) Strain Relief Test of Clause 16.5,d)
Installation instructions shall be provided for
assembly of terminal to a conductor and strain
relief, e)Terminals shall be appropriate for use with
the size and type of wire specified.”
No such voltage.
N/A
15.1.3.2
- Add: "Audio amplifiers having an audio output not
limited to 120 V that are connected to the mains
by a flexible cord shall have suitable cord or
provision for field installation or a receptacle for
plug-in connections."
limited to 120 V that are connected to the mains
by a flexible cord shall have suitable cord or
provision for field installation or a receptacle for
plug-in connections."
No such voltage.
N/A
15.2
- Add after 3rd paragraph: “The earthing conductor
in a supply cord, or in an interconnecting cable
shall have an equivalent or larger cross-sectional
area that the current-carrying conductors in the
supply cord or cable. With reference to earthing
conductors, the insulation color may be green or
green/yellow.
in a supply cord, or in an interconnecting cable
shall have an equivalent or larger cross-sectional
area that the current-carrying conductors in the
supply cord or cable. With reference to earthing
conductors, the insulation color may be green or
green/yellow.
Class II
N/A
15.3.5
- Revise 2nd paragraph to read: “For rated
currents exceeding 13 A, reference is made to
Article 310 of the National Electrical Code,
ANSI/NFPA 70.”
Table 15 - Replace with: “Nominal cross-sectional
area AWG“ and modify values.
currents exceeding 13 A, reference is made to
Article 310 of the National Electrical Code,
ANSI/NFPA 70.”
Table 15 - Replace with: “Nominal cross-sectional
area AWG“ and modify values.
N/A
15.4
- Add: ”Component power supply adaptors
complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
or UL 60950 are considered to fulfill the test
requirements on the clause.”
complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
or UL 60950 are considered to fulfill the test
requirements on the clause.”
N/A
16.1
- Modification: Mains supply flexible cords shall
comply with UL 817, be marked VW-1, and have
an ampacity not less than the current drawn by the
apparatus. Delete references to IEC 602227,
60245 and 60173.
Table 17A - Add: Types of cords and cord lengths
for various types of apparatus.
comply with UL 817, be marked VW-1, and have
an ampacity not less than the current drawn by the
apparatus. Delete references to IEC 602227,
60245 and 60173.
Table 17A - Add: Types of cords and cord lengths
for various types of apparatus.
PVC, complying with
IEC60227, UL approved
IEC60227, UL approved
Pass
page 42 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
16.2
- An integral earthing conductor shall be at least
the same size as the other cord conductors.
Substitute “IEC 60950, table 3B” with “Article 400
of the National Electrical Code”.
Table 18 – Replace with “Wire sizes of external
flexible cords” Upper current limit in column 1
increased from 16 to 30 A and “AWG” wire sizes
added.
the same size as the other cord conductors.
Substitute “IEC 60950, table 3B” with “Article 400
of the National Electrical Code”.
Table 18 – Replace with “Wire sizes of external
flexible cords” Upper current limit in column 1
increased from 16 to 30 A and “AWG” wire sizes
added.
18AWG Pass
16.3
- Add: c) Flexible cords not complying with 16.1,
used as connection between the apparatus and
other apparatus used in combination with it, shall
be marked VW-1.
used as connection between the apparatus and
other apparatus used in combination with it, shall
be marked VW-1.
No such interconnection cord
used
used
N/A
17.8
- Expanded to include all cart/stand parts supplied
by the manufacturer, such as casters and
brackets.
Suitable assembly instructions required. Add:
"Relevant fixing means are not required when
installation is to be done by a skilled person."
by the manufacturer, such as casters and
brackets.
Suitable assembly instructions required. Add:
"Relevant fixing means are not required when
installation is to be done by a skilled person."
N/A
17.10
- Add: Aluminum conductors used as internal
wiring shall be terminated by a method capable of
being used in the combination of metals involved
at the connection point.
wiring shall be terminated by a method capable of
being used in the combination of metals involved
at the connection point.
N/A
17.11
- Add: An accessory shall be investigated to
determine that: a) The accessory, and the
combination of the accessory and the apparatus
shall present no hazard in the sense of this
standard and b) The accessory
is provided with installation instructions.
determine that: a) The accessory, and the
combination of the accessory and the apparatus
shall present no hazard in the sense of this
standard and b) The accessory
is provided with installation instructions.
N/A
17.11.1
- Add: The installation of an accessory of a skilled
person shall be such that: a) The mechanical
positioning is accomplished by means of tools
normally available or by means of special tools
provided by the organization responsible for
providing the apparatus as part of the installation
kit, and b) The electrical connections are made by
using existing terminals and connections in the
apparatus or the building wiring.
person shall be such that: a) The mechanical
positioning is accomplished by means of tools
normally available or by means of special tools
provided by the organization responsible for
providing the apparatus as part of the installation
kit, and b) The electrical connections are made by
using existing terminals and connections in the
apparatus or the building wiring.
N/A
18
- Modification: Non-intrinsically protected picture
tubes shall comply with 18.1, 18.2.2 and
18.3.Intrinsically protected picture tubes shall
comply with UL 1418 or UL 61965.
Add: “A bulb of a picture tube having a face
diameter of 7.5 cm or more shall be mounted in an
enclosure. The enclosure shall have no opening
that exceeds 130 mm2 unless the minor
dimension of the opening is 10 mm or less.”
tubes shall comply with 18.1, 18.2.2 and
18.3.Intrinsically protected picture tubes shall
comply with UL 1418 or UL 61965.
Add: “A bulb of a picture tube having a face
diameter of 7.5 cm or more shall be mounted in an
enclosure. The enclosure shall have no opening
that exceeds 130 mm2 unless the minor
dimension of the opening is 10 mm or less.”
N/A