Harman Kardon BDS 577 EMC - CB Certificate ▷ View online

 
Page 27 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
16 
T501 pin8-9 
S-C 
-- 
Unit shutdown immediately, no damaged, no 
hazard. Input current:0.046A 
Duration: 10 min. 
17 
T502 pin2-4 
S-C 
-- 
Audio output shutdown immediately, USB 
output worked as normal, no damaged, no 
hazard. Input current:0.170A 
Duration: 10 min. 
18 
T502 pin12,13-
14,15 
S-C 
-- 
Audio output shutdown immediately, USB 
output worked as normal, no damaged, no 
hazard. Input current:0.170A 
Duration: 10 min. 
19 
T502 pin12,13-
10,11 
S-C 
-- 
Audio output shutdown immediately, USB 
output worked as normal, no damaged, no 
hazard. Input current:0.170A 
Duration: 10 min. 
20 
* BD501 
S-C 
-- 
F1, BD1 were damaged, no hazard, no 
breakdown. Input current:>17.4A 
Duration: 10 min. 
21 
* CE501 
S-C 
-- 
F1, BD1 were damaged, no hazard, no 
breakdown. Input current:>17.4A 
Duration: 10 min. 
22 
U502 pin1-7 
S-C 
-- 
Audio output shutdown immediately, USB 
output worked as normal, no damaged, no 
hazard. Input current:0.312A 
Duration: 10 min. 
23 
* Q506 pin 
G-D 
S-C 
-- 
F1, U502 were damaged, no hazard, no 
breakdown. Input current: :>17.4A 
Duration: 10 min. 
24 
R587 
S-C 
-- 
Unit worked as normal, no damaged, no 
hazard. Input current:0.315A 
Duration: 10 min. 
25 
U501 pinV-S 
S-C 
-- 
Unit worked as normal, no damaged, no 
hazard. Input current:0.315A 
Duration: 30 min. 
26 
* Q513 pinD-S 
S-C 
-- 
F1, Q514, BD1 were damaged, no hazard, no 
breakdown. Input current: :>17.4A 
Duration: 10 min. 
27 
CE503 
S-C 
-- 
Audio output shutdown immediately, USB 
output worked as normal, no damaged, no 
hazard. Input current:0.288A 
Duration: 10 min. 
28 
D507 
S-C 
-- 
Unit shutdown immediately, no damaged, no 
hazard. Input current:0.045A 
Duration: 10 min. 
29 
D509 
S-C 
-- 
Unit shutdown immediately, no damaged, no 
hazard. Input current: 0.045A 
Duration: 10 min. 
 
Page 28 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
30 
D514 
S-C 
-- 
Audio output shutdown immediately, USB 
output worked as normal, no damaged, no 
hazard. Input current:0.170A 
Duration: 10 min. 
31 
Audio output 
terminal 
Maximum 
non-
clipped 
T501: 44.5, 
T502: 54.5,  
Enclosure:18.9 
Apparatus worked for 9 min, then input and 
audio output bouncing, USB output normal. 
No damaged, no hazard. Input current 
bouncing from 1.08A to 0.045A.  
Duration: 30 min. 
32 
DC motor of 
optical pick up 
Blocked   T501: 48.3, 
T502: 41.1,  
spindle motor: 13.3, 
Enclosure: 17.8. 
Unit could not worked as normal,  
No damaged, no hazard. Input current: 
0.197A.  
Duration: 130 min. 
33 
USB port 
O-L 
T501: 52.2, 
T502: 45.3, 
Enclosure: 21.0. 
The maximum external loaded current was 
2.32A and ran for thermal equilibrium under it. 
Over 2.32A, the unit shut down immediately.  
No damaged, no hazard. 
Duration: 146 min. 
34 
Opening  
Blocked 
T501: 52.3, 
T502: 46.1, 
Enclosure: 17.8. 
Unit worked as normal, no damaged, no 
hazard, input current: 0.315A 
Duration: 77 min. 
 
35 
Fan  
Blocked 
T501: 76.0, 
T502: 66.6, 
Enclosure: 25.9. 
Unit worked as normal, no damaged, no 
hazard, input current: 0.345A 
Duration: 160 min. 
36 
One Audio output 
terminal  
(Front left) 
S-C 
T501: 52.1, 
T502: 45.5, 
Enclosure: 21.9. 
Other audio output terminals were worked as 
normal except the one which shorted. No 
damaged, no hazard.  
Input current: 0.541A drop to 0.325A; 
Duration: 100 min. 
Supplementary information: 
1) S-C: short circuit, O-L: overload, O-C: open circuit; 
2) The Hi-pot test conducted successfully after the completion of fault condition test; 
3) *:  Test repeated on all alternate Fuse sources and results were same. 
4)  T501, T502 winding and/or core limited: 130K, spindle motor limited: 125K, Enclosure limited: 55K. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page 29 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
13 
TABLES: clearances and creepage distances 
Rated supply voltage:  100-240V 
Pollution degree .. : 
Material Group .... :  IIIb 
2 N force on internal parts applied: 
Yes 
30 N force on outside of conductive enclosure applied: 
-- 
N/A 
 
Location 
Working Voltage 
Clearance (mm) 
Creepage (mm) 
 
V rms 
V peak 
Min 
Actual 
Min 
Actual 
L to N 
240 
340 
2.0 
3.6 
2.4 
3.6 
Between F501 
240 
340 
2.0 
5.8 
2.4 
5.8 
Between pin of BD501 
240 
340 
2.0 
2.0 
2.4 
4.0 
CY506 Primary to secondary 
240 
340 
4.0 
7.1 
4.8 
7.1 
Live part BD501 to metal screw connected to 
metal panel 
240 
340 
4.0 
7.0 
4.8 
7.0 
Live part heatsink HS1 to metal panel 
240 
340 
4.0 
10.0 
4.8 
10.0 
T501 Primary to secondary under PCB trace 
368 
668 
4.8 
9.0 
7.6 
9.0 
T501 Primary winding to secondary winding 
368 
668 
4.8 
8.0 
7.6 
8.0 
T501 core to Primary 
368 
668 
2.4 
4.0 
3.8 
4.0 
T501 core to secondary 
368 
668 
2.4 
4.0 
3.8 
4.0 
T502 Primary to secondary under PCB trace 
368 
668 
4.8 
10.3 
7.6 
10.3 
T502 Primary Winding to secondary winding 
368 
668 
4.8 
8.6 
7.6 
8.6 
T502 core to Primary 
368 
668 
2.4 
5.5 
3.8 
5.5 
T502 core to secondary 
368 
668 
2.4 
5.5 
3.8 
5.5 
U505 Primary to secondary 
240 
361 
4.0 
6.5 
4.8 
6.5 
U506 Primary to secondary 
240 
364 
4.0 
6.5 
4.8 
6.5 
CY504 Primary to secondary 
240 
370 
4.0 
7.4 
4.8 
7.4 
U508 Primary to secondary 
240 
369 
4.0 
6.5 
4.8 
6.5 
PCB primary trace to metal panel 
368 
668 
4.8 
9.0 
7.6 
9.0 
Power board primary components  to main 
board secondary components 
240 
340 
4.0 
6.5 
4.8 
10.0 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. 
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in 
Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed (e.g. 
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in 
Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an earthed 
metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth via a 
component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from 
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 
or 10 as required, then the value for clearance is used as the minimum creepage distance. 
"Min" = minimum required. "Actual = Actual dimensions measured.
 
 
Page 30 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
  
14 
TABLE: list of critical components and materials 
  
Object / part 
No. 
Manufacturer/ 
trademark 
Type / model 
Technical data 
Standard 
Mark(s) of 
conformity1) 
DVD Unit 
DONGGUAN 
YINGLIANG 
ELECTRON CO., 
LTD. 
BD-19 
Including OPU 
IEC/EN 60065  Tested in 
appliance 
-OPU 
SANYO Electric Co., 
Ltd. 
SF-BD415 
Including Laser 
Diode 
IEC 60825-1, 
21 CFR Part 
1040.10 
JQA 
 
-Laser Diode  ROHM CO., LTD. 
RLD2WM 
CD: 790±6nm 
DVD: 660+10/-
4nm 
IEC 60825-1, 
21 CFR Part 
1040.10 
JQA 
-Laser Diode  SANYO Electric Co., 
Ltd. 
DL-4146 
BD: 405±7nm 
IEC 60825-1, 
21 CFR Part 
1040.10 
JQA 
DC fan 
JINGXIN 
METAL&PLASTIC 
RPODUCTS(HUIZHO
U) CO., LTD 
JD5020LS1 
 
DC 12V, 0.13A, 
9.48CFM 
UL 507 
UL  
Alternative 
NS MICRO MOTOR 
THCHNOLOGY 
CORP 
PAAD15020SL  12V, <0.16A, 
15CFM 
UL 507 
UL 
Switch  
Zhejiang Bei Er Jia 
Electronic Co., Ltd. 
PS8A 
For UL: 125Vac, 
10A (load:GP), 
85°C, 6K; 
For VDE: 250Vac, 
8A/108A T105/55, 
10E3 
EN 61058-1 
UL 61058 
VDE, UL 
(Alternative) 
Wenzhou LiYang 
Electronics Co., Ltd. 
KCD1 
For UL: 250Vac, 
6A (load: GP), 
85°C, 10K; 
For VDE: 250Vac, 
6A, T85/55, 10E3 
EN 61058-1 
UL 61058 
VDE, UL 
(Alternative) 
Zhangjiagang Huajie 
Electronic Co., Ltd. 
PS8-338 
For UL: 120Vac, 
5A (load:TV), 
50°C, 25K; 
For VDE: 250Vac, 
8A/128A  T85/55, 
10E3 
EN 61058-1 
UL 61058 
TUV, UL 
(Alternative) 
Zhejiang LECI 
Electronics Co., Ltd 
RS601 
For UL: 250Vac, 
6A (load: GP), 
105°C, 6K; 
For VDE: 250Vac, 
6A, T85/55, 10E3 
EN 61058-1 
UL 61058 
VDE, UL 
Page of 127
Display

Click on the first or last page to see other BDS 577 service manuals if exist.