Harman Kardon BDS 577 EMC - CB Certificate ▷ View online

 
Page 15 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked  
(See appended table 14) 
14.6 
Switches  
Certified all-pole switch used 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage  
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 
N/A 
 
Switch controlling < 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1  
No mains socket outlets used 
N/A 
 
Socket outlet current marking correct  
 
N/A 
14.7 
Safety interlocks  
No safety interlocks 
N/A 
 
Safety interlocks to 2.8 of IEC 60950-1 
 
N/A 
14.8 
Voltage setting devices and the like  
No voltage setting devices 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 
N/A 
14.9 
Motors 
Only DC motor used in 
secondary circuit 
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
 
N/A 
14.9.3 
Protection against moving parts  
 
 
Page 16 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950-1, Annex B  
 
N/A 
14.10 
Batteries 
Non-rechargeable batteries 
used in the remote controller 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 
N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 
Optocouplers  
Approved optocouplers (U505, 
U506, U508) used.  
Dti.≥0.4mm. 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
 
b) Comply with IEC 60747-5-5:2007 
 
N/A 
 
Alternative to a) and b) optocoupler comply with 13.8   
N/A 
14.12 
Surge suppression varistors  
Approved surge suppression 
varistor RV501 used 
 
Comply with IEC 61051-2  
 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
 
 
15 
Terminals 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
Mains plug and appliance inlet 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
 
 
 N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
 
 
No risk of insertion in mains socket-outlets  
 
 
Page 17 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
 
No risk of insertion into audio- or video- outlets 
marked with the symbol of 5.2  
No such terminals used 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets  
 
N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II equipment 
N/A 
 
Protective earth conductors correctly coloured  
 
N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 
N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance  test: < 0,1 
 at 25 A  ................... : 
 
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
No such terminals 
N/A 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
Not permanent wiring 
N/A 
15.3.2 
Reliable connection of non-detachable cords  
 
N/A 
 
Not soldered to conductors of a printed circuit board    
N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
 
N/A 
 
Wire secured by additional means to the  
conductor   
 
N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 
N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16    
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 
N/A 
 
Page 18 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
 
N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand  
 
N/A 
15.4 
Devices forming a part of the mains plug  
 
N/A 
15.4.1 
No undue strain on mains socket-outlets  
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 
N/A 
 
16 
External flexible cords 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ............................................................ : 
Approved power cord used 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
(See appended table 14) 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2)  
 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
 
N/A 
16.5 
Adequate strain relief on external flexible cords  
Detachable power cord used 
N/A 
 
Not possible to push cord back into equipment  
 
N/A 
 
Strain relief device unlikely to damage flexible  
cord  
 
N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor  
 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use  
 
N/A 