Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
 
 
b) Hazardous live terminals, instructions for wiring   
No such terminals 
N/A 
 
c) Instructions for replacing lithium battery  
 
N/A 
 
d) Class I earth connection warning  
 
N/A 
 
e) Instructions for multimedia system connection  
 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 
N/A 
 
g) Warning: battery exposure to heat  
Batteries in remote control  
 
h) Warning: protective film on CRT face 
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
AC inlet was used as 
disconnect device 
 
c) Instructions for permanently connected equipment    
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 
N/A 
 
Hazardous radiation 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No ionizing radiation 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
 ................................................................................... : 
Class 1  
 
Emission limits under fault conditions  ..................... :  Class 1  
 
7 
Heating under normal operating conditions 
 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table) 
7.1.1 
Temperature rise of accessible parts  
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table) 
7.1.4 
Temperature rise of windings  
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
LF501, LF502, L501, T501, 
T502 bobbin 
 
Constructional requirements with regard to the protection against electric 
shock 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
  
 
Page 8 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
  
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
No hygroscopic material used 
N/A 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
 
8.5 
Class I equipment  
Class II equipment 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
Class II equipment  
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
Isolating transformer T501 and 
T502 used  
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)   
Approved Y1-cap. (CY501, 
CY502, CY504, CY506) used 
8.7 
This clause is void  
 
— 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
T501 Bobbin: min. 1.0mm 
 
Reinforced insulation > 0,4 mm (mm)  .................... : 
T502 Bobbin: min. 0.9mm 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
Insulation tape wrapped in 
T501. 
 
 
Page 9 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
 
Reinforced insulation, three layers any two which 
meet 10.3  
 
N/A 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
 
 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts. 
 
8.11 
Detaching of wires  
 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
 
 
Vibration test carried out  ......................................... : 
Considered 
8.12 
This clause is void  
 
— 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
 
N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
 
8.19.1 
Disconnect device  
AC inlet was used as 
disconnect device  
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 
N/A 
8.19.2 
Mains switch ON indication  
 
8.20 
Switch not fitted in the mains cord  
 
8.21 
Bridging components comply with clause 14  
No such components 
N/A 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
<1000Vac or <1500Vdc 
N/A 
9.1.1.1 
a) Open circuit voltages  
 
 
Page 10 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
U1: 19000mV, U2: 267mV 
Limit: U1:35000mV, 
U2:350mV 
 
c) Discharge not exceeding 45 
μC  
 
 
d) Energy of discharge not exceeding 350 mJ 
 
N/A 
9.1.1.2 
Test with test finger and test probe  
Can’t touch hazardous parts 
9.1.2 
No hazardous live shafts of knobs, handles or levers   No such parts 
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set control 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
13.5V after 2s 
 
If C is not greater than 0,1 
μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
50N 
 
b) Test hook of fig. 4 for 10 s (20 N)  
20N 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
100N 
9.2 
No hazard after removing a cover by hand  
Cover cannot be removed by 
hand 
N/A 
 
10 
Insulation requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 
MΩ min. for reinforced 
insulation  ................................................................. : 
(see appended table) 
10.2 
Humidity treatment 48 h or 120 h  ........................... : 
120 hour, 40
C, 93% 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
 
 
11 
Fault conditions 
 
11.1 
No shock hazard under fault condition  
 
11.2 
Heating under fault condition  
 
 
Flames extinguish within 10 seconds  
 