Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
b) Hazardous live terminals, instructions for wiring
No such terminals
N/A
c) Instructions for replacing lithium battery
N/A
d) Class I earth connection warning
N/A
e) Instructions for multimedia system connection
P
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
N/A
g) Warning: battery exposure to heat
Batteries in remote control
P
h) Warning: protective film on CRT face
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
AC inlet was used as
disconnect device
disconnect device
P
c) Instructions for permanently connected equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
N/A
6
Hazardous radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
................................................................................... :
................................................................................... :
Class 1
P
Emission limits under fault conditions ..................... : Class 1
P
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
LF501, LF502, L501, T501,
T502 bobbin
T502 bobbin
P
8
Constructional requirements with regard to the protection against electric
shock
shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
P
Page 8 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
P
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
N/A
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
P
8.5
Class I equipment
Class II equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Isolating transformer T501 and
T502 used
T502 used
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
Approved Y1-cap. (CY501,
CY502, CY504, CY506) used
CY502, CY504, CY506) used
P
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
T501 Bobbin: min. 1.0mm
P
Reinforced insulation > 0,4 mm (mm) .................... :
T502 Bobbin: min. 0.9mm
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
Insulation tape wrapped in
T501.
T501.
P
Page 9 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
P
Vibration test carried out ......................................... :
Considered
P
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
P
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
P
8.19.1
Disconnect device
AC inlet was used as
disconnect device
disconnect device
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
No such components
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
<1000Vac or <1500Vdc
N/A
9.1.1.1
a) Open circuit voltages
P
Page 10 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1: 19000mV, U2: 267mV
Limit: U1:35000mV,
U2:350mV
U2:350mV
P
c) Discharge not exceeding 45
μC
P
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
Can’t touch hazardous parts
P
9.1.2
No hazardous live shafts of knobs, handles or levers No such parts
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set control
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
13.5V after 2s
P
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
50N
P
b) Test hook of fig. 4 for 10 s (20 N)
20N
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
100N
P
9.2
No hazard after removing a cover by hand
Cover cannot be removed by
hand
hand
N/A
10
Insulation requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4
surge test for basic and 4
MΩ min. for reinforced
insulation ................................................................. :
(see appended table)
P
10.2
Humidity treatment 48 h or 120 h ........................... :
120 hour, 40
C, 93%
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
P
11
Fault conditions
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
P