Harman Kardon BDS 577 EMC - CB Certificate ▷ View online
Page 11 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
No hazard from softening solder
P
Soldered terminations not used as protective
mechanism
mechanism
N/A
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
(see appended table)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
N/A
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
(see appended table)
P
12
Mechanical strength
—
12.1.1
Bump test where mass >7 kg
3.4 kg
N/A
12.1.2
Vibration test
P
12.1.3
Impact hammer test
P
Steel ball test
P
12.1.4
Drop t
est for portable apparatus where mass ≤ 7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
76
C, 7 h
P
12.2
Fixing of knobs, push buttons, keys and levers
50N force for push-buttons on
front panel
front panel
P
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
P
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
Page 12 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
—
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
13.2
Determination of working voltage
668Vp, 368Vrms
P
13.3
Clearances
P
13.3.1
General
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ............. :
with table 8 and, where applicable, table 9 ............. :
(see appended table)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
P
Creepage distances greater than table 11 minimum
values
values
(see appended table)
P
13.5
Printed boards
Certified PWB used
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
No coated PCB
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
similar devices, if insulation is relied upon for safety
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12
not conductively connected to the mains, clearances
and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14
Components
—
14.1
Resistors
No such resistors used
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N/A
Page 13 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
(see appended table 14)
N/A
Resistors separately approved ............................... :
No
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved :
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition
……:
Approved Y1-cap. (CY501,
CY502, CY504, CY506) used
CY502, CY504, CY506) used
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition
……:
X2 capacitor: CX501, CX502
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ........................................................................ :
metal ........................................................................ :
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
(see appended table)
P
Transformers and inductors separately approved . :
No
N/A
14.3.2
General
P
Insulation material complies with clause 20.1.4
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4
Separation between windings
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) .............................. :
between hazardous live parts and accessible parts
(double or reinforced insulation) .............................. :
Double or reinforced insulation
between T501, T502 primary
and secondary winding
between T501, T502 primary
and secondary winding
P
Coil formers and partition walls > 0,4 mm
T501 Bobbin: min. 1.0mm
T502 Bobbin: min. 0.9mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
Page 14 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
See Cl. 14.3.4.1
P
Coil formers and partition walls > 0,4 mm
T501 Bobbin: min. 1.0mm
T502 Bobbin: min. 0.9mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high voltage components
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
P
Protective devices used within their ratings
F501
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-out
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
VDE approved.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
―F501, T6.3AH250V‖ marked
near fuse on PCB
near fuse on PCB
P
14.5.2.3
Not possible to connect fuses in parallel ................ :
Fuse soldered on PCB
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
Fuse soldered in the
apparatus, user
apparatus, user
can’t
replaceable.
N/A
14.5.3
PTC thermistors comply with IEC 60730-1:2007
N/A
PTC devices (15 W) category V-1 or better
N/A
Click on the first or last page to see other BDS 577 service manuals if exist.