Harman Kardon AVR 155 (serv.man2) EMC - CB Certificate ▷ View online
-
Page 39 of 43 -
Report
No.
97240
Monitored point:
Under fault conditions specified below - continued
Under fault conditions specified below - continued
dT (K)
dT (K)
#)
*), Speaker output (Center- ch.), S-c;
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard. (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard. (Tested time: 10 min).
N/A N/A
*), Ventilation opening (Blocked);
Unit shut down after 16 min.
The components are maximum temperature:
1) Main transformer primary winding
2) Main transformer core
3) Sub transformer primary winding
4) Sub transformer core
5) PWB near D991
Input current stabilised at 0,008A. No component damaged.
Dielectric strength test O.K. No hazard. (Tested time: 16 min)
Unit shut down after 16 min.
The components are maximum temperature:
1) Main transformer primary winding
2) Main transformer core
3) Sub transformer primary winding
4) Sub transformer core
5) PWB near D991
Input current stabilised at 0,008A. No component damaged.
Dielectric strength test O.K. No hazard. (Tested time: 16 min)
1) 83,0
2) 62,9
3) 41,8
4) 36,2
5) 83,4
2) 62,9
3) 41,8
4) 36,2
5) 83,4
1) 150
2) 150
3) 150
4) 150
5) 110
2) 150
3) 150
4) 150
5) 110
*), Pmax. Operating (Maximum non-clipped output signal);
1st.
Main transformer primary winding maximum temperature 158,8K and
thermal fuse opened after 10 min 28 sec. Input current stabilised at 0,008A.
Dielectric strength test O.K. No hazard (Tested time: 10 min 28 sec).
2nd.
Main transformer primary winding maximum temperature 156,3K and
thermal fuse opened after 10 min 5 sec. Input current stabilised at 0,008A.
Dielectric strength test O.K. No hazard (Tested time: 10 min 5 sec).
3rd.
Main transformer primary winding maximum temperature 149,4K and
thermal fuse opened after 9 min 40 sec. Input current stabilised at 0,027A.
Dielectric strength test O.K. No hazard (Tested time: 9 min 40 sec).
1st.
Main transformer primary winding maximum temperature 158,8K and
thermal fuse opened after 10 min 28 sec. Input current stabilised at 0,008A.
Dielectric strength test O.K. No hazard (Tested time: 10 min 28 sec).
2nd.
Main transformer primary winding maximum temperature 156,3K and
thermal fuse opened after 10 min 5 sec. Input current stabilised at 0,008A.
Dielectric strength test O.K. No hazard (Tested time: 10 min 5 sec).
3rd.
Main transformer primary winding maximum temperature 149,4K and
thermal fuse opened after 9 min 40 sec. Input current stabilised at 0,027A.
Dielectric strength test O.K. No hazard (Tested time: 9 min 40 sec).
Main transf.
158,8
Main transf.
156,3
Main transf.
149,4
Main transf.
150
Main transf.
150
Main transf.
150
*) Tested voltage 253V **) Tested voltage 198V
#) Temperature rise limits for Singapore is 10K less
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
-
Page 40 of 43 -
Report
No.
97240
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference *)
Main
transformer
Bobbin Mtl.
Thermal fuse
transformer
Bobbin Mtl.
Thermal fuse
Seoul Electronics
& Telecom Co Ltd.
Wintech Polymer
Therm-O-Disc
& Telecom Co Ltd.
Wintech Polymer
Therm-O-Disc
.
KLT5V045ZE
CLT5V045ZE
CN9030
E4A51167C
CLT5V045ZE
CN9030
E4A51167C
Class B
PET, V-0, 155
°C
10A/250V, 167
°C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL, E213445
VDE
UL, E213445
VDE
Sub
transformer
transformer
(T902)
Bobbin Mtl.
Bobbin Cap. Mtl.
Seoul Electronics
LG Chemical Ltd.
LG Chemical Ltd.
LG Chemical Ltd.
CLT5I009ZE/
KLT5I009ZE
KLT5I009ZE
GP-2306G
GP-1006F
GP-1006F
Class E
V-0, 140°C, PBT
V-0, 130°C, PBT
V-0, 130°C, PBT
IEC60065
clause 14.3
UL94
UL94
clause 14.3
UL94
UL94
1.)
UL, E67171
UL, E67171
Mains fuse
(F901)
alt.
alt.
(F901)
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Electronic.
Littelfuse.
SUN Electronics
Walter Electronic.
50T
218
218
004
5T
TSD
TSD
T4A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Outlet fuse
(F902)
alt.
alt.
(F902)
alt.
alt.
Littelfuse B.V.
Bel Fuse.
Save Fusetech.
Bel Fuse.
Save Fusetech.
Wickmann
-
Werke.
0663
MRT
SR-5
TR5 382
MRT
SR-5
TR5 382
T2.5A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Relay across
the cap (C904)
alt.
alt.
alt.
the cap (C904)
alt.
alt.
alt.
Du San
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
X1.
IEC60384-14,
2
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
Mains relay
(RY94) alt.
(RY94) alt.
Omron Corp.
Daiichi Elect.
Daiichi Elect.
G5PA-1
DLS1U
DLS1U
3A/100A 250V
5A/100A 250V
5A/100A 250V
IEC 61058-1
IEC 61058-1
IEC 61058-1
SEMKO
SEMKO
SEMKO
Mains switch
(BN90)
(BN90)
Jackson Elect.
JS-606
6A 250V
IEC60065
IEC61058-1
FIMKO
Socket-outlet
(OL91)
(OL91)
Dae Ryung Elect.
Dongbo Industri.
Dongbo Industri.
A3-02-D006
A302D006
A302D006
2.5A/250V ~
2.5A/250V ~
2.5A/250V ~
IEC60884-1
IEC60884-1
IEC60884-1
NEMKO
NEMKO
NEMKO
Enclosure Mtl.
Body, top cover
Front panel
alt.
Body, top cover
Front panel
alt.
Various
Kumho Chemi.
Various
Various
HFA-452
Various
Sheet Steel,
Min. 0.80 mm
V-2, Min. 2.0 mm
V-2 or better
Min. 2,0mm thick
-
UL94
UL94
1.)
UL, E65424
UL
PCB Various
Various
Min. V-1, 130
°C UL 796
UL
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to IEC 60065, 7.Edition
-
Page 41 of 43 -
Report
No.
97240
14
TABLE: list of critical components and materials-continued
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference *)
Mains plug/cord
(For CENELEC)
(For CENELEC)
KENIC
ELECTRIC.
ELECTRIC.
KE-21
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt. KENIC
ELECTRIC.
KE-32
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt. PHINO
ELECT.
PHP-205
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt. VOLEX
(ASIA)
PTE.
M4206
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
Mains plug / cord
(For Korea)
(For Korea)
See “Summary of testing”
Mains plug/cord
(For UK and
Singapore)
(For UK and
Singapore)
KENIC
ELECTRIC.
ELECTRIC.
KE-108
H03VVH2-F, or
H05VVH2-F
H03VVH2-F, or
H05VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
SS145
SS145
BSI
PSB
PSB
Mains plug/cord
(For UK)
(For UK)
PHINO ELECT. PHP-307F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. VOLEX
(ASIA)
PTE.
MP5004A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. VOLEX
(ASIA)
PTE.
MP5005
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. WINBO
INDUSTRIES
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
LUEN TAI (IP’S)
KENIC ELECT.
KENIC ELECT.
9518
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
WELL SHIN EN
TERPRISE.
TERPRISE.
WS-012A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to IEC 60065, 7.Edition
-
Page 42 of 43 -
Report
No.
97240
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Class II apparatus
N/A
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Class II apparatus
N/A
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
P
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
Class II apparatus
N/A
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
P
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
Class II apparatus.
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
BSI approved plug and cord
provided
provided
P
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
When marketing in Ireland,
the apparatus must be
supplied with a cord and plug
acceptable in Ireland.
the apparatus must be
supplied with a cord and plug
acceptable in Ireland.
N/A
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
P
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
Comply
P
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
Comply
P
- protecting rim also tested
Class II apparatus
N/A