- Page 15 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
12.6 
Telescoping or rod antennas construction 
No telescoping or rod 
antennas
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
See attachment, Table to  
EN/IEC 60065 7
th
 edition.
 
 
Creepage distances in accordance with 13.4 
See attachment, Table to 
EN/IEC 60065 7
th
 edition.
 
13.2 
Determination of operating voltage 
Conventional transf. used. 
Upper rated supply voltage 
applied in determining the 
operating voltage
 
13.3 Clearances 
2N for internal parts and 
30N for enclosures are 
considered when 
determining clearances. 
13.3.1 General 
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
See attachment, Table to 
EN/IEC 60065 7
th
 edition.
 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
No hazardous secondary 
voltages
 
N/A 
13.3.4 
Measurement of transient voltages 
No measurement of 
transient voltages 
N/A 
13.4 Creepage 
distances 
CTI > 100 
See attachment, Table to  
EN/IEC 60065 7
th
 edition. 
 
 
Creepage distances greater than table 11 minima 
Not applicable
 
N/A 
13.5 Printed 
boards 
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of 
which may be conductively connected to the 
mains, as in fig. 10 
No such PCB used
 
N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
No type B coated printed  
circuit boards
 
N/A 
 
 
- Page 16 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
Jointed insulation not 
applied
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
 
Temperature cycle test and dielectric strength test
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
No enclosed, enveloped or 
hermetically sealed parts
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
No parts filled with 
insulating compound.
 
N/A 
 
 
 
 
14 COMPONENTS 
 
14.1 Resistors 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such resistors
 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
Not used
 
N/A 
 Resistors 
separately approved  .......................... : 
 
N/A 
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes  
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition : 
No Y capacitors
 
N/A 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition : 
C904 is Certified X capacitor 
by IEC 60384-14, 2
nd
 edition  
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ................. : 
No such capacitors
 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better  ...................................................................... : 
Several E. capacitors 
Volume >1750mm
3
, but 
metal cases. 
N/A 
 
 
- Page 17 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better  ..................................... : 
Several E. capacitors 
Volume >1750mm
3
, but 
metal cases. 
N/A 
 
Shielded by a barrier 
acc. to 20.1.4/ table 21
 or 
metal  ....................................................................... : 
 
N/A 
14.3 
Inductors and windings 
See below.
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
Transformers evaluated  
according to 14.3.3, 14.3.4 
and 14.3.5
 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ........................... : 
Adequate marking applied. 
Mfr. ID and type no. 
 
Transformers and inductors separately approved 
 ................................................................................. : 
No 
N/A 
14.3.2 General 
Isolating transformer
 
 
Insulation material complies  with clause 20.1.4 
 
14.3.3 Constructional 
requirements 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
See attachment, Table to 
EN/IEC 60065 7
th
 edition.
 
14.3.3.2 
Transformers meet the constructional 
requirements 
See attachment, Table to  
EN/IEC 60065 7
th
 edition.
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible 
parts (double or reinforced insulation) 
Double or reinforced  
insulation between primary  
and secondary windings  
according to clause 8.8. 
See attachment, Table to  
EN/IEC 60065 7
th
 edition. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin of transformers 
fulfils the requirement of  
reinforced insulation;  
bobbin thickness > 0,4 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Transformers are evaluated 
with Class II construction
 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
Windings of Class II  
construction used.
 
N/A 
 
 
- Page 18 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible 
parts (double or reinforced insulation) 
Double or reinforced  
insulation between  
hazardous live windings  
and accessible conductive  
parts. 
 
Coil formers and partition walls > 0,4 mm 
The bobbins fulfils the  
requirement of reinforced  
insulation; bobbins  
thickness > 0,4 mm. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Windings of Class II  
construction used.
 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
         
 
N/A 
14.4 
High voltage components 
No high-voltage 
components 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested 
as part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 Protective 
devices 
 
 
Protective devices used within their ratings 
Thermal link and fuses
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across 
the device when opened 
Certified protective devices 
applied.   
See appended table, list of 
critical component. 
14.5.1.1 
a) Thermal cut-outs separately approved 
No thermal cut-outs.
 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
Page of 57