Harman Kardon AVR 155 (serv.man2) EMC - CB Certificate ▷ View online
- Page 31 of 43 -
Report
No.
97240
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to
the building installation via a non-industrial
plug or a non-industrial appliance coupler, or
both and in addition is intended for connection
to other equipment or a network shall, if safety
relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts,
have a marking stating that the equipment
must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries
shall be as follow:
In Finland,
"Laite on liitettävä
suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to
the building installation via a non-industrial
plug or a non-industrial appliance coupler, or
both and in addition is intended for connection
to other equipment or a network shall, if safety
relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts,
have a marking stating that the equipment
must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries
shall be as follow:
In Finland,
"Laite on liitettävä
suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Class II apparatus
N/A
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
N/A
L5.4
Marking and Instructions
N/A
L9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in
Table 3 , unless comply with 6.3.2 of IEC
60086-4
Table 3 , unless comply with 6.3.2 of IEC
60086-4
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
No electronic flash
apparatus
apparatus
N/A
-
Page 32 of 43 -
Report
No.
97240
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
No mains switch
—
Position of the functional switch (W) ................ :
In OFF/Stand-by position,
the power consumption is
less than 0,8W.
the power consumption is
less than 0,8W.
—
Operating conditions
Standby mode at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
253 0,007 0,7 —
230 0,007 0,6 —
220 0,007 0,6 —
198 0,007 0,5 —
Standby mode at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
253 0,008 0,8 —
242 0,007 0,8 —
230 0,007 0,7 —
220 0,007 0,7 —
198 0,007 0,6 —
Measured at maximum non-clipped output at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
253
3,00
646
2 x 59,4 W
(F)
1 x 60,0 W
(C)
2 x 60,5 W
(S)
Measured at maximum non-clipped output at 60Hz;
253
2,91
631
2 x 59,4 W
(F)
1 x 60,0 W
(C)
2 x 60,5 W
(S)
Tested condition: 1kHz input signal, connected 8 ohm loads for F, C, S channels
-
Page 33 of 43 -
Report
No.
97240
Measured at 1/8 of maximum non-clipped output at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
253
1,43
#) 1,40
278
#) 274
2 x 7,43 W
(F)
1 x 7,50 W
(C)
2 x 7,56 W
(S)
230
1,39
#) 1,35
245
#) 240
2 x 7,43 W
(F)
1 x 7,50 W
(C)
2 x 7,56 W
(S)
220
1,37
#) 1,33
233
#) 227
2 x 7,43 W
(F)
1 x 7,50 W
(C)
2 x 7,56 W
(S)
198
1,33
#) 1,28
205
#) 198
2 x 7,43 W
(F)
1 x 7,50 W
(C)
2 x 7,56 W
(S)
Measured at 1/8 of maximum non-clipped output at 60Hz;
253
1,42
#) 1,40
277
#) 272
2 x 7,43 W
(F)
1 x 7,50 W
(C)
2 x 7,56 W
(S)
242
1,37
#) 1,36
257
#) 255
2 x 7,43 W
(F)
1 x 7,50 W
(C)
2 x 7,56 W
(S)
230
1,35
#) 1,34
242
#) 238
2 x 7,43 W
(F)
1 x 7,50 W
(C)
2 x 7,56 W
(S)
220
1,34
#) 1,31
229
#) 225
2 x 7,43 W
(F)
1 x 7,50 W
(C)
2 x 7,56 W
(S)
198
1,30
#) 1,27
203
#) 196
2 x 7,43 W
(F)
1 x 7,50 W
(C)
2 x 7,56 W
(S)
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads connected condition, and
then replaced the input signal to pink noise for heating and fault condition tests.
then replaced the input signal to pink noise for heating and fault condition tests.
The values followed #) in table above are measured “A” or “W” value, when replaced the input signal
from 1 kHz sign wave to pink noise.
from 1 kHz sign wave to pink noise.
Loudspeaker impedance (Ω) ......
8 Ohm
—
Several loudspeaker systems
Right and Left for Front,
Only one for Center,
Right and Left for Surround channels.
Only one for Center,
Right and Left for Surround channels.
P
Marking of loudspeaker
terminals
terminals
SPEAKERS (8
Ω): FRONT, CENTER,
SURR.
P
-
Page 34 of 43 -
Report
No.
97240
Measured at 1/8 of maximum non-clipped output;
Monitored point:
dT (K) at
253V, 50Hz
dT (K) at
198V, 50Hz
dT (K) at
253V, 60Hz
dT (K) at
198V, 60Hz
Limit dT (K) *
)
Main transformer core
58,1 45,6 55,9 44,0 95
Sub transformer core
31,2 22,2 30,1 21,7 85
D991 heat-sink
67,2 57,8 65,5 57,3 -
PWB near D991
70,5 60,9 68,7 60,5 95
D992 heat-sink
51,3 44,3 50,4 43,8 -
PWB near D992
49,7 42,5 48,7 42,1 95
Q657 body
75,8 50,3 70,8 49,9 -
PWB near Q657
59,3 39,9 55,8 39,6 95
C909 capacitor body
26,2 19,0 25,8 18,6 85
°C
Main heat-sink
66,6 44,4 62,6 44,2 -
C941 capacitor body
32,9 22,3 31,4 21,8 85
°C
IC91 body
71,4 46,2 66,8 45,8 -
PWB near IC91
61,9 40,7 58,2 40,4 95
Power cord bushing
23,8 17,0 23,1 16,5 60
Top cover above main transformer
29,7
22,1
28,7
21,2
40
Top cover above main heat-sink
45,6
30,3
43,2
30,4
65 **)
Power switch button (non-metallic)
7,0
2,1
6,8
1,9
50
Front panel (non-metallic)
16,7
8,5
16,0
8,4
60
*) Temperature rise limits for Singapore is 10K less
**) Directly covering part for main heat-sink. The top cover is supplied with ventilation openings covering
most of the top cover. This indicates emission of heat from internal parts and the opening area is
therefore not likely to be touched during normal use.
Winding temperature rise
measurements
measurements
253V,
50Hz
198V,
50Hz
253V,
60Hz
198V,
60Hz
—
Ambient temperature t1 (
o
C) :
22,6 22,6 22,6 22,6
—
Ambient temperature t2 (
o
C) :
21,0 27,6 21,7 27,7
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K)
*)
Insulation
class
Main transf. primary winding (253V, 50Hz)
3,13 4,10 81,3 95 B
Sub transf. primary winding (253V, 50Hz)
4527 5198 39,7 85
E
Main transf. primary winding (198V, 50Hz)
3,13 4,01 67,3 95 B
Sub transf. primary winding (198V, 50Hz)
4527 5144 30,0 85
E
Main transf. primary winding (253V, 60Hz)
3,13 4,08 78,9 95 B
Sub transf. primary winding (253V, 60Hz)
4527 5192 38,7 85
E
Main transf. primary winding (198V, 60Hz)
3,13 4,01 67,2 95 B
Sub transf. primary winding (198V, 60Hz)
4527 5137 29,5 85
E
*) Temperature rise limits for Singapore is 10K less