Harman Kardon AVR 155 (serv.man2) EMC - CB Certificate ▷ View online

 
 
- Page 23 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
Approved mains plug and  
socket-outlet provided,  
see list of critical component
s. 
 
Overloading of plugs or appliance inlets 
prevented if the apparatus has mains socket 
outlets 
Prevented by the fuse; 
F902 (T2.5A L 250V).
 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets 
No internal wirings for 
socket-outlets.
 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
P
 
 
No risk of insertion in mains socket-outlets 
Only RCA, Optical,  RS-232, 
HDMI, Antenna and S-video 
terminals used.  
Banana plug type speaker  
terminal also used, but they  
are accepted due to below  
note. 
 
Note:  
Banana plug type speaker  
terminals are blocked in their 
axial holes to prevent use of  
plugs that can make  
permanent contact with a  
mains socket outlet. 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
No sockets indicated with 
the symbol 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar 
devices not compatible with household mains 
socket-outlets 
The equipment under test 
is not an adaptor.
 
N/A 
15.2 
Provision for protective earthing 
N/A
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II apparatus
 
N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
 
- Page 24 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 
N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0,1 
Ω at 25 A  ............... : 
 
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
Apparatus is not for  
permanent connection.
 
N/A 
15.3.2 
Reliable connection of non-detachable cords: 
.
 
 
Not soldered to conductors of a printed circuit 
board 
Not soldered
 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
Wires are clamped two  
times to the contact  
terminal and provided with 
a two-pole connector
 
 
Wire secured by additional means to the 
conductor 
Adequately anchored.  
Tested with 5 N.
 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
No screws and nuts  
clamping
 
N/A 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
No soldered conductors.
 
N/A 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
Clamped insulators and  
conductors
 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
Terminals have adequate  
connection capacity.
 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16  
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
No clamps.
 
N/A 
 
Terminals designed to avoid conductor slipping 
out when tightened or loosened 
 
N/A 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 
N/A 
 
 
- Page 25 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
No contact pressure trans
mitted through insulating
 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
The termination of the 
contacts are in adequate  
proximity to each other.
 
 
Terminals located and shielded: test with 8 mm 
strand 
Clamped contacts within  
connector
 
N/A 
15.4 
Devices forming a part of the mains plug 
 
N/A 
15.4.1 
No undue strain on mains socket-outlets 
The apparatus is not a  
device forming a part of 
the mains plug.
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 
N/A 
 
 
 
 
16 
EXTERNAL FLEXIBLE CORDS 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ......................................................... : 
Sheathed PVC cord 
complying with IEC 60227 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
Class II apparatus
 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of 
the equipment 
The cord is min. 0,75mm², 
within the current rating 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 
No interconnecting cables 
comprising hazardous live 
conductors.
 
N/A 
 
 
- Page 26 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
 
b) Flexible cords not complying with 16.1, 
withstand bending and mechanical stress (3.2 of 
IEC 60227-2) 
Cord complying with 16.1.
 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
Cords have adequate 
cross-sectional areas to  
avoid temperature rise under 
normal and fault conditions. 
16.5 
Adequate strain relief on external flexible cords 
Cord clip wedged in the 
enclosure 
 
Not possible to push cord back into equipment 
Checked by inspection
 
 
Strain relief device unlikely to damage flexible 
cord 
No sharp edges
 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth 
conductor 
Class II apparatus.
 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
No sharp edges
 
N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
The apparatus is not a  
transportable musical 
instrument and amplifier
 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
The apparatus is not a 
transportable musical 
instrument and amplifier
 
N/A 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to table 20: 
Screws fixing chassis to the
 main enclosure tested.
 
 
- screws into metal: 5 times 
See attachment, Table to 
EN/IEC 60065 7
th
 edition. 
 
- screws into non-metallic material: 10 times 
 
N/A 
17.2 
Correct introduction into female threads in non-
metallic material 
No female threads in  
non-metallic materials 
N/A 
17.3 
Cover fixing screws: captive 
Captivity not necessary
 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
Tested with screw with  
10 times diameter.
 