Harman Kardon AVR 155 (serv.man2) EMC - CB Certificate ▷ View online
- Page 19 of 43 -
Report
No.
97240
14.5.1.2
a) Thermal links separately approved
The thermal link in
main transformer separately
approved. See appended
table, list of critical comp.
main transformer separately
approved. See appended
table, list of critical comp.
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices
re-settable
re-settable
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are approved
components according to
IEC 60127.
See list of critical components
components according to
IEC 60127.
See list of critical components
P
14.5.2.2
Correct marking of fuse-links adjacent to holder
................................................................................. :
................................................................................. :
Marked on PCB adjacent
to fuses as;
F901: T4A L 250V,
F902: T2.5A L 250V
to fuses as;
F901: T4A L 250V,
F902: T2.5A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ......... :
No fuses holder so
designed that fuse-links
can be connected in parallel
designed that fuse-links
can be connected in parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .. :
replacing fuse-links without the use of a tool .. :
No replacement of fuses
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No PTC’s thermistors.
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking
capacity and their position is correctly marked
capacity and their position is correctly marked
N/A
- Page 20 of 43 -
Report
No.
97240
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
Make and break speed independent of speed of
actuation
actuation
V-0 compliance with annex G, G.1.1
Yes, mains switch and relay
provided. Certified acc. to
IEC61058-1.
- Mains relay, certified by
SEMKO.
- Mains switch, certified by
FIMKO.
See appended table, list of
critical components.
provided. Certified acc. to
IEC61058-1.
- Mains relay, certified by
SEMKO.
- Mains switch, certified by
FIMKO.
See appended table, list of
critical components.
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved relay.
N/A
- Page 21 of 43 -
Report
No.
97240
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
Measured inrush current
through mains switch is
through mains switch is
< 1 A.
The measured inrush current
is less than rated current of
the mains switch (6A) - O.K..
Measured inrush current
through mains relay =
= 34A + 20 A *
*) Added current for socket
outlet marked “0.5 A”.
The measured surge current
value is less than rated inrush
current rating of the mains
relay (100A). - O.K.
(The mains socket outlet is
controlled by the mains relay).
is less than rated current of
the mains switch (6A) - O.K..
Measured inrush current
through mains relay =
= 34A + 20 A *
*) Added current for socket
outlet marked “0.5 A”.
The measured surge current
value is less than rated inrush
current rating of the mains
relay (100A). - O.K.
(The mains socket outlet is
controlled by the mains relay).
P
Socket outlet current marking correct
SWITCHED, 50W, 0.5A MAX
P
14.7 Safety
interlocks
No safety interlock
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
and the like
No voltage setting devices
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
No motors
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-
phase motors and series motors meet clause. B.8,
B.9 and B.10 of IEC 60950, Annex B
phase motors and series motors meet clause. B.8,
B.9 and B.10 of IEC 60950, Annex B
No such construction.
N/A
14.10 Batteries
No batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
P
- Page 22 of 43 -
Report
No.
97240
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
No optocouplers
N/A
Optocouplers comply with Cl. 8
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N/A
14.12
Surge suppression varistors
No surge suppression
varistors
varistors
N/A
Comply with IEC 61051-2
N/A
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A