- Page 19 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
14.5.1.2 
a) Thermal links separately approved 
The thermal link in  
main transformer separately 
approved. See appended 
table, list of critical comp.
 
 
b) Thermal links tested as part of the submission   
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
No thermal devices 
re-settable
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuses are approved 
components according to 
IEC 60127. 
See list of critical components
 
14.5.2.2 
Correct marking of fuse-links adjacent to holder 
 ................................................................................. : 
Marked on PCB adjacent 
to fuses as; 
F901: T4A L 250V, 
F902: T2.5A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ......... : 
No fuses holder so 
designed that fuse-links  
can be connected in parallel 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  .. : 
No replacement of fuses 
possible by hand.
 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No PTC’s thermistors.
 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking 
capacity and their position is correctly marked 
 
N/A 
 
 
- Page 20 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
14.6 Switches 
 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
Make and break speed independent of speed of 
actuation 
V-0 compliance with annex G, G.1.1 
Yes, mains switch and relay 
provided. Certified acc. to  
IEC61058-1.  
 
-  Mains relay, certified by  
 SEMKO. 
-  Mains switch, certified by  
 FIMKO. 
 
See appended table, list of  
critical components. 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 
N/A 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 
N/A 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
Separately approved relay.
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
Separately approved relay.
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
Separately approved relay.
 
N/A 
 
 
- Page 21 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
Measured inrush current 
through mains switch is 
< 1 A. 
The measured inrush current 
is less than rated current of 
the mains switch (6A) - O.K.. 
 
Measured inrush current 
through mains relay =  
 = 34A + 20 A * 
*) Added current for socket 
  outlet marked “0.5 A”. 
 
The measured surge current 
value is less than rated inrush 
current rating of the mains 
relay (100A). - O.K. 
 
(The mains socket outlet is 
controlled by the mains relay). 
 
Socket outlet current marking correct 
SWITCHED, 50W, 0.5A MAX
 
14.7 Safety 
interlocks 
No safety interlock
 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
 
N/A 
14.8 
Voltage setting devices 
and the like
 
No voltage setting devices
 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
 
N/A 
14.9 Motors 
No motors
 
N/A 
14.9.1 
Endurance test on motors 
 
N/A 
 
Motor start test 
 
N/A 
 
Dielectric strength test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
14.9.3 
Protection against moving parts 
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-
phase motors and series motors meet clause. B.8, 
B.9 and B.10 of IEC 60950, Annex B 
No such construction.
 
N/A 
14.10 Batteries 
No batteries
 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 
 
 
- Page 22 of 43 - 
 
 
 
 
 Report 
No. 
97240 
 
 
 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 
N/A 
14.10.3 
Recharging currents and times within 
manufacturers limits 
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 
N/A 
14.10.4 
Battery mould stress relief 
 
N/A 
14.10.5 
Battery drop test 
 
N/A 
14.11 Optocouplers 
No optocouplers
 
N/A 
 
Optocouplers comply with Cl. 8 
 
N/A 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
 
N/A 
14.12 
Surge suppression varistors 
No surge suppression  
varistors 
N/A 
 
Comply with IEC 61051-2 
 
N/A 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
 
N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 
N/A 
Page of 57