97240
Measured at 1/8 of maximum non-clipped output;
Monitored point:
dT (K) at
242V, 60Hz
Limit dT (K)
Main transformer core
54,6
95
Sub transformer core
27,1
85
D991 heat-sink
62,2
-
PWB near D991
65,9
95
D992 heat-sink
47,0
-
PWB near D992
45,4
95
Q657 body
71,4
-
PWB near Q657
55,2
95
C909 capacitor body
21,6
85
°C
Main heat-sink
62,2
-
C941 capacitor body
28,8
85
°C
IC91 body
67,1
-
PWB near IC91
57,6
95
Power cord bushing
19,6
60
Top cover above main transformer
25,7
40
Top cover above main heat-sink
41,4
65 *)
Power switch button (non-metallic)
2,5
50
Front panel (surface,
Aluminium
)
12,2
60
*) Directly covering part for main heat-sink. The top cover is supplied with ventilation openings covering
most of the top cover. This indicates emission of heat from internal parts and the opening area is
therefore not likely to be touched during normal use.
Winding temperature rise
measurements
measurements
242V,
60Hz
—
Ambient temperature t1 (
o
C) :
22,6
—
Ambient temperature t2 (
o
C) :
27,1
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K) Insulation
class
Main transf. primary winding (242V, 60Hz)
3,13 4,12 76,8 95 B
Sub transf. primary winding (242V, 60Hz)
4527 5232 35,5 85
E
-
Page 36 of 43 -
Report
No.
97240
7.2
TABLE: softening temperature of thermoplastics
N/A
Temperature T of part
T - normal con-
ditions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
2
Between parts separated by double or reinforced insulation
> 100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500Vac No
Between parts separated by double or reinforced insulation
3000Vac No
-
Page 37 of 43 -
Report
No.
97240
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ......... :
253V or 198V
—
Ambient temperature (
o
C) ................................... :
23 - 26
o
C
—
Monitored point:
Under fault conditions specified below
Under fault conditions specified below
dT (K)
dT (K)
#)
*), D114 (A to C), S-c;
Unit shut down after 4 min. Input current stabilised at 0,008A.
R104 opened. No hazard (Tested time: 10 min).
Unit shut down after 4 min. Input current stabilised at 0,008A.
R104 opened. No hazard (Tested time: 10 min).
N/A N/A
*), D117 (A to C), S-c;
Unit shut down after 10 min. Input current stabilised at 0,008A.
R105 opened. No hazard (Tested time: 11 min).
Unit shut down after 10 min. Input current stabilised at 0,008A.
R105 opened. No hazard (Tested time: 11 min).
N/A N/A
*), D104 (A to C), S-c;
Unit shut down after 11 min. Input current stabilised at 0,008A.
R106 opened. No hazard (Tested time: 15 min).
Unit shut down after 11 min. Input current stabilised at 0,008A.
R106 opened. No hazard (Tested time: 15 min).
N/A N/A
**), D104 (A to C), S-c;
Normal operated. Input current stabilised at 1,31A.
Main transformer primary winding temperature stabilised.
No hazard (Tested time: 1 hr 35 min).
Normal operated. Input current stabilised at 1,31A.
Main transformer primary winding temperature stabilised.
No hazard (Tested time: 1 hr 35 min).
Main transf.
73,5
Main transf.
150
*), C131, S-c;
Output signal off immediately. Input current stabilised at 0,54A.
D124, D125, R106 and R107 damaged. No hazard (Tested time: 30 min).
Output signal off immediately. Input current stabilised at 0,54A.
D124, D125, R106 and R107 damaged. No hazard (Tested time: 30 min).
N/A N/A
*), C117, S-c;
Unit shut down after 10 min. Input current stabilised at 0,008A.
No component damaged. No hazard (Tested time: 15 min).
Unit shut down after 10 min. Input current stabilised at 0,008A.
No component damaged. No hazard (Tested time: 15 min).
N/A N/A
*), C119, S-c;
FL display off immediately. Input current stabilised at 1,38A.
Main transformer primary winding temperature stabilised.
Q104 damaged. No hazard (Tested time: 1 hr 50 min).
FL display off immediately. Input current stabilised at 1,38A.
Main transformer primary winding temperature stabilised.
Q104 damaged. No hazard (Tested time: 1 hr 50 min).
Main transf.
87,8
Main transf.
150
*), C941, S-c;
FL display off immediately. Input current stabilised at 1,34A.
D104, D105, R106 and R107 damaged. No hazard (Tested time: 30 min).
FL display off immediately. Input current stabilised at 1,34A.
D104, D105, R106 and R107 damaged. No hazard (Tested time: 30 min).
N/A N/A
*), C929, S-c;
Output signal off immediately. Input current stabilised at 0,37A.
R104 and R105 opened. No hazard (Tested time: 30 min).
Output signal off immediately. Input current stabilised at 0,37A.
R104 and R105 opened. No hazard (Tested time: 30 min).
N/A N/A
*), D991 (AC to +), S-c;
F901 opened. Input current stabilised at 0,008A.
No hazard (Tested time: 10 min).
F901 opened. Input current stabilised at 0,008A.
No hazard (Tested time: 10 min).
N/A N/A
**), D991 (AC to +), S-c;
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard (Tested time: 10 min).
N/A N/A
*) Tested voltage 253V **) Tested voltage 198V
#) Temperature rise limits for Singapore is 10K less
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
-
Page 38 of 43 -
Report
No.
97240
Monitored point:
Under fault conditions specified below - continued
Under fault conditions specified below - continued
dT (K)
dT (K)
#)
*), D992 (AC to +), S-c;
F901 opened. Input current stabilised at 0,008A.
No hazard (Tested time: 10 min).
F901 opened. Input current stabilised at 0,008A.
No hazard (Tested time: 10 min).
N/A N/A
**), D992 (AC to +), S-c;
Unit shut down immediately. Input current stabilised at 0,005A.
No component damaged. No hazard (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,005A.
No component damaged. No hazard (Tested time: 10 min).
N/A N/A
*), C902, S-c;
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard (Tested time: 10 min).
N/A N/A
**), C902, S-c;
Unit shut down immediately. Input current stabilised at 0,005A.
No component damaged. No hazard (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,005A.
No component damaged. No hazard (Tested time: 10 min).
N/A N/A
*), C916, S-c;
Unit shut down immediately. Input current stabilised at 0,007A.
No component damaged. No hazard (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,007A.
No component damaged. No hazard (Tested time: 10 min).
N/A N/A
**), C916, S-c;
Unit shut down immediately. Input current stabilised at 0,005A.
No component damaged. No hazard (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,005A.
No component damaged. No hazard (Tested time: 10 min).
N/A N/A
*), D901 (A to C), S-c;
Normal operated. Input current stabilised at 1,30A.
Dielectric strength test O.K. No hazard (Tested time: 1 hr 54 min).
Normal operated. Input current stabilised at 1,30A.
Dielectric strength test O.K. No hazard (Tested time: 1 hr 54 min).
Sub transf.
73,3
Sub transf.
150
*), C906, S-c;
Unit shut down immediately. Input current stabilised at 0,014A.
Sub transformer primary winding temperature stabilised.
Dielectric strength test O.K. No hazard (Tested time: 1 hr).
Unit shut down immediately. Input current stabilised at 0,014A.
Sub transformer primary winding temperature stabilised.
Dielectric strength test O.K. No hazard (Tested time: 1 hr).
Sub transf.
72,5
Sub transf.
150
*), C631, S-c;
Center output signal off immediately. Input current stabilised at 1,26A.
R631 opened. No hazard (Tested time: 30 min).
Center output signal off immediately. Input current stabilised at 1,26A.
R631 opened. No hazard (Tested time: 30 min).
N/A N/A
*), Q657 (E to C), S-c;
Unit shut down immediately. Input current stabilised at 0,008A.
Q661 and R656 damaged. No hazard. (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,008A.
Q661 and R656 damaged. No hazard. (Tested time: 10 min).
N/A N/A
*), Q657 (B to C), S-c;
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard. (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard. (Tested time: 10 min).
N/A N/A
*), Q661 (E to C), S-c;
Unit shut down immediately. Input current stabilised at 0,008A.
R656 opened. No hazard. (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,008A.
R656 opened. No hazard. (Tested time: 10 min).
N/A N/A
*), Q661 (B to C), S-c;
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard. (Tested time: 10 min).
Unit shut down immediately. Input current stabilised at 0,008A.
No component damaged. No hazard. (Tested time: 10 min).
N/A N/A
*) Tested voltage 253V **) Tested voltage 198V
#) Temperature rise limits for Singapore is 10K less
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded