Harman Kardon AVR 151 (serv.man5) EMC - CB Certificate ▷ View online
Page 37 of 50
Report No.: 232173
TRF No. IEC60065K
No.
Component
Fault
Duration
of the test
Other results
(include description)
(include description)
dT (K) / Component
dT (K)
Permitted
dT(K) ***)
dT(K) ***)
10.
*), #)
*), #)
Q914
(D to S)
(D to S)
SC
10 min
Normal operated.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
N/A N/A
11.
*), #)
*), #)
IC99
(pin 3 to 1)
(pin 3 to 1)
SC
10 min
Normal operated.
The operating mode changed to
LOW mode after 2 min 20 s.
FI stabilised at 0.82 A.
NCD. No hazard.
The operating mode changed to
LOW mode after 2 min 20 s.
FI stabilised at 0.82 A.
NCD. No hazard.
N/A N/A
12
*), #)
*), #)
D921
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
13
*), #)
*), #)
C944
SC
30 min
Unit shut down immediately.
FI changed between 0.05 A and
0.07 A periodically.
NCD. No hazard.
FI changed between 0.05 A and
0.07 A periodically.
NCD. No hazard.
N/A N/A
14
*), #)
*), #)
C984
SC
30 min
Unit shut down immediately.
FI changed between 0.05 A and
0.07 A periodically.
NCD. No hazard.
FI changed between 0.05 A and
0.07 A periodically.
NCD. No hazard.
N/A N/A
15
*), #)
*), #)
D942
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
16
**), #)
**), #)
D942
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
17
*), #)
*), #)
C928
SC
2 hr
All speakers output off immediately.
FI changed between 0.28 A and
2.11 A periodically.
Measured highest temperature;
1) TF93 coil
2) TF93 core and stabilised.
Dielectric strength test.
No hazard.
FI changed between 0.28 A and
2.11 A periodically.
Measured highest temperature;
1) TF93 coil
2) TF93 core and stabilised.
Dielectric strength test.
No hazard.
85.7
70.2
70.2
140 ****)
150
*) Tested voltage 264V
**) Tested voltage 198V
Apparatus mode:
#) HIGH mode
##) LOW mode
***) Temperature rise limits for tropical climate is 10 K less.
****) Minus (-) 10K applied for thermo-couple method for windings
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
Page 38 of 50
Report No.: 232173
TRF No. IEC60065K
No.
Component
Fault
Duration
of the test
Other results
(include description)
(include description)
dT (K) / Component
dT (K)
Permitted
dT(K) ***)
dT(K) ***)
18
*), #)
*), #)
C937 SC 1
hr
20 min
All speakers output off immediately.
FI changed between 0.28 A and
2.14 A periodically.
Measured highest temperature;
1) TF93 coil
2) TF93 core and stabilised.
Dielectric strength test.
No hazard.
FI changed between 0.28 A and
2.14 A periodically.
Measured highest temperature;
1) TF93 coil
2) TF93 core and stabilised.
Dielectric strength test.
No hazard.
87.3
72.0
72.0
140 ****)
150
19
*), #)
*), #)
D950
(A to C)
(A to C)
SC
10 min
Normal operated.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
N/A N/A
20
*), #)
*), #)
PC93
(pin 3 to 4)
(pin 3 to 4)
SC
10 min
All speakers output off immediately.
FI stabilised at 0.27 A.
NCD. No hazard.
FI stabilised at 0.27 A.
NCD. No hazard.
N/A N/A
21
*), #)
*), #)
PC93
(pin 1 to 2)
(pin 1 to 2)
SC
10 min
All speakers output off immediately.
FI stabilised at 0.27 A.
NCD. No hazard.
FI stabilised at 0.27 A.
NCD. No hazard.
N/A N/A
22
*), #)
*), #)
PC96
(pin 3 to 4)
(pin 3 to 4)
SC
10 min
Normal operated.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
N/A N/A
23
*), #)
*), #)
PC96
(pin 1 to 2)
(pin 1 to 2)
SC
10 min
All speakers output off immediately.
FI stabilised at 0.27 A.
NCD. No hazard.
FI stabilised at 0.27 A.
NCD. No hazard.
N/A N/A
24
*), #)
*), #)
PC92
(pin 3 to 4)
(pin 3 to 4)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
25
*), #)
*), #)
PC92
(pin 1 to 2)
(pin 1 to 2)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
IC91, R923, R922, R990 and D921
damaged. No hazard.
FI stabilised at 0.06 A.
IC91, R923, R922, R990 and D921
damaged. No hazard.
N/A N/A
26
*), #)
*), #)
PC95
(pin 1 to 2)
(pin 1 to 2)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
*) Tested voltage 264V
**) Tested voltage 198V
Apparatus mode:
#) HIGH mode
##) LOW mode
***) Temperature rise limits for tropical climate is 10 K less.
****) Minus (-) 10K applied for thermo-couple method for windings
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
Page 39 of 50
Report No.: 232173
TRF No. IEC60065K
No.
Component
Fault
Duration
of the test
Other results
(include description)
(include description)
dT (K) / Component
dT (K)
Permitted
dT(K)
27
*), #)
*), #)
PC95
(pin 3 to 4)
(pin 3 to 4)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
28
*), #)
*), #)
PC94
(pin 3 to 4)
(pin 3 to 4)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
29
*), #)
*), #)
PC94
(pin 1 to 2)
(pin 1 to 2)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
30
*), #)
*), #)
PC91
(pin 3 to 4)
(pin 3 to 4)
SC
10 min
Normal operated.
The operating mode changed to
LOW mode after 2 min 20 s.
FI stabilised at 0.82 A.
NCD. No hazard.
The operating mode changed to
LOW mode after 2 min 20 s.
FI stabilised at 0.82 A.
NCD. No hazard.
N/A N/A
31
*), #)
*), #)
PC91
(pin 1 to 2)
(pin 1 to 2)
SC
10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
32
*), #)
*), #)
C401 SC 10 min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
33
*), #)
*), #)
C152 SC 10 min
Unit shut down immediately.
FI changed between 0.05 A and
0.07 A periodically.
NCD. No hazard.
FI changed between 0.05 A and
0.07 A periodically.
NCD. No hazard.
N/A N/A
34
*), #)
*), #)
C452 SC 10 min
All speakers output and FL display
off immediately.
FI stabilised at 0.35 A.
NCD. No hazard.
off immediately.
FI stabilised at 0.35 A.
NCD. No hazard.
N/A N/A
35
*), ##)
*), ##)
Q804
(C to E)
(C to E)
SC 10
min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
36
*), ##)
*), ##)
Q804
(C to B)
(C to B)
SC 10
min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
37
*), ##)
*), ##)
C808 SC 10
min
Normal operated.
FI stabilised at 0.82 A.
NCD. No hazard.
FI stabilised at 0.82 A.
NCD. No hazard.
N/A N/A
*) Tested voltage 264V
**) Tested voltage 198V
Apparatus mode:
#) HIGH mode
##) LOW mode
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
Page 40 of 50
Report No.: 232173
TRF No. IEC60065K
No.
Component
Fault
Duration
of the test
Other results
(include description)
(include description)
dT (K) / Component
dT (K)
Permitted
dT(K)
38
*), #)
*), #)
Q803
(C to E)
(C to E)
SC 10
min
Unit shut down immediately.
FI stabilised at 0.06 A.
Q804 damaged. No hazard.
FI stabilised at 0.06 A.
Q804 damaged. No hazard.
N/A N/A
39
*), #)
*), #)
Q803
(C to B)
(C to B)
SC 10
min
Unit shut down immediately.
FI stabilised at 0.06 A.
NCD. No hazard.
FI stabilised at 0.06 A.
NCD. No hazard.
N/A N/A
40
*), #)
*), #)
C807 SC 10
min
Normal operated.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
N/A N/A
41
*), #)
*), #)
DB91
(AC to “+”)
(AC to “+”)
SC 1
s F901 fuse opened immediately.
No hazard.
N/A N/A
42
**), #)
**), #)
DB91
(AC to “+”)
(AC to “+”)
SC 1
s F901 fuse opened immediately.
No hazard.
N/A N/A
43
*), #)
*), #)
DB91
(AC to “-”)
(AC to “-”)
SC 1
s F901 fuse opened immediately.
No hazard.
N/A N/A
44
*), #)
*), #)
C901 SC 1
s F901 fuse opened immediately.
No hazard.
N/A N/A
45
**), #)
**), #)
C901 SC 1
s F901 fuse opened immediately.
No hazard.
N/A N/A
46
*), #)
*), #)
D944
(A to C)
(A to C)
SC 10
min
Normal operated.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
The operating mode changed to
LOW mode after 2 min 30 s.
FI stabilised at 0.82 A.
NCD. No hazard.
N/A N/A
47
*), #)
*), #)
Q901
(pin 2 to 1)
(pin 2 to 1)
SC 1
s F901 fuse opened immediately.
Q901 and IC93 damaged.
No hazard.
No hazard.
N/A N/A
48
*), #)
*), #)
Q901
(pin 2 to 3)
(pin 2 to 3)
SC 1
s F901 fuse opened immediately.
No hazard.
N/A N/A
49
*), #)
*), #)
D901
(A to C)
(A to C)
SC
1 s
F901 fuse opened immediately.
D902 damaged. No hazard.
D902 damaged. No hazard.
N/A N/A
50
*), #)
*), #)
C902
SC
1 s
F901 fuse opened immediately.
D902 damaged. No hazard.
D902 damaged. No hazard.
N/A N/A
*) Tested voltage 264V
**) Tested voltage 198V
Apparatus mode:
#) HIGH mode
##) LOW mode
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
Click on the first or last page to see other AVR 151 (serv.man5) service manuals if exist.