DOWNLOAD Harman Kardon AVR 151 (serv.man5) Service Manual ↓ Size: 5.88 MB | Pages: 106 in PDF or view online for FREE

Model
AVR 151 (serv.man5)
Pages
106
Size
5.88 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-151-sm5.pdf
Date

Harman Kardon AVR 151 (serv.man5) EMC - CB Certificate ▷ View online

Page 45 of 50 
Report No.: 232173 
  
TRF No. IEC60065K 
 
14.3.3 Transformer/motor, 
constructional 
requirements 
Transformer 
Part No. 
Insulation 
between 
Insulation 
Res.  
M Ohms 
Test Volt 
V (60 sec.)
Clearances / Creepage  
distances 
Measured 
Required 
TF91 (CLT9Z087ZE) 
Pr. - Sec. 
> 5.2 
3000 Vac 
6.0 / 6.0 
4.6 / 5.0  
TF92 (CLT9Z088ZE) 
Pr. - Sec. 
> 5.2 
3000 Vac 
6.5 / 6.5 
4.6 / 6.0 *) 
TF93 (CLT9Z089ZE) 
Pr. - Sec. 
> 5.2 
3000 Vac 
7.0 / 7.0 
4.4 / 6.4 
 
 
 
 
 
 
*)  Liner interpolation applied for creepage distances 
Components / construction 
TF91 (CLT9Z087ZE) 
Windings on single bobbin. 
Three (3) layers of insulation used between primary 
winding and iron core / secondary winding.  
Satisfactory constructed. Bobbin thickness: > 0,4mm. 
 
#) Max. working voltage: 585Vpeak / 245Vrms  
Components / construction 
TF92 (CLT9Z088ZE) 
Windings on single bobbin. 
Three (3) layers of insulation used between primary 
winding and secondary winding.  
Satisfactory constructed. Bobbin thickness: > 0,4mm. 
 
#) Max. working voltage: 640Vpeak / 280Vrms  
Components / construction 
TF93 (CLT9Z089ZE) 
Windings on single bobbin. 
Three (3) layers of insulation used between primary 
winding and iron core / secondary winding 
Satisfactory constructed. Bobbin thickness: > 0,4mm. 
 
#) Max. working voltage: 560Vpeak / 260Vrms  
 
 
 
 
#) Measured highest working voltage for transformer between primary and secondary. 
 
Page 46 of 50 
Report No.: 232173 
  
TRF No. IEC60065K 
 
Transformer 
Part No 
Insulation 
Between 
Thick (mm) 
X Number 
Material 
Dielectric strength test 
/ 60 sec. 
TF91 
(CLT9Z087ZE)  
Pr. – ic. 
0.60 mm min 
Phenolic bobbin 
Pass *) 
Pr. – ic. 
0.025 mm min. x 3
Ployester film tape 
2 layers tested – Pass *)
Pr. – sec. 
0.025 mm min. x 3
Ployester film tape 
2 layers tested – Pass *)
 
 
 
 
 
TF92 
(CLT9Z088ZE) 
Pr. – ic. 
0.70 mm min 
Phenolic bobbin 
Pass *) 
Pr. – sec. 
0.025 mm min. x 3
Ployester film tape 
2 layers tested – Pass *)
 
 
 
 
 
TF93 
(CLT9Z089ZE) 
Pr. – ic. 
0.70 mm min 
Phenolic bobbin 
Pass *) 
Pr. – ic. 
0.025 mm min. x 3
Ployester film tape 
2 layers tested – Pass *)
Pr. – sec. 
0.025 mm min. x 3
Ployester film tape 
2 layers tested – Pass *)
 
 
 
 
 
*) Test voltage: 3000 Vrms  
 
 
17.1 
Torque test to Table 20: 
Screw 
Location / function 
Diameter 
(mm) 
With 
Head 
Without
Head 
Material 
Torque test (Nm) 
Fulfilled / Remarks 
Screw 
Nut 
Fixing of top cover 
(side) 
4.0 
Metal 
Metal 
1.2 Nm, 5 times / Pass 
4.0 
Metal 
Plastic
1.2 Nm, 10 times / Pass 
Fixing of top cover 
(rear) 
3.0 
Metal 
Metal 
0.5 Nm, 5 times / Pass 
 
 
 
 
 
 
 
 
 
 
Page 47 of 50 
Report No.: 232173 
  
TRF No. IEC60065K 
 
14 
TABLE: list of critical components and materials 
Object / part 
No. 
Manufacturer/ 
trademark 
Type / model
Technical data 
Standard 
Approval/ 
Ref. **) 
Mains cord set 
(For CENELEC 
countries)      *) 
Volex (Asia) Pte 
Ltd 
M3204 
H05VV-F 
VAC17S 
10/16A, 250V 
0.75 mm
2
 x 2 
10A/250V 
IEC60884-1 
IEC60227 
IEC60320 
VDE 
VDE 
VDE 
Alt.) 
Kenic Electric Mfg. 
Co., Ltd. 
KE-25 
H05VV-F 
KE-48 
16A, 250V 
0.75 mm
2
 x 2 
10A/250V 
IEC60884-1 
IEC60227 
IEC60320 
VDE 
VDE 
VDE 
Mains cord set 
(For China) 
*) 
Volex (Asia) Pte Ltd  V301C 
 
RVV 300/500 
VAC17S 
10A/250V 
 
1.0 mm
2
 x 2 
10A/250V 
GB1002 
GB2009 
GB5023.5 
GB17465.1 
CQC 
 
CQC 
CQC 
Mains cord set 
(For UK and 
Singapore) 
*) 
Volex (Asia) Pte Ltd  MP5004 
MP5004A 
H05VV-F 
VAC17S 
13A/250V 
 
0.75 mm
2
 x 2 
10A/250V 
BS1363 
SS145 
BS6500 
YEC60320 
ASTA, PSB 
ASTA, PSB 
ASTA 
VDE 
Appliance inlet 
Rich Bay Co., Ltd.  R-301(21) 
15A/250V 
IEC 60320 
VDE 
AC connector 
(CN90)
 
Yeon Ho 
electronics 
YW396 series 
Min. 5A/250V~ 
IEC 60065 
UL 1977 
1.) 
UL, E108706
Mains fuse 
(F901) 
Littelfuse Inc 
215 
T6.3A H 250V 
IEC 60127 
VDE 
Transformer 
(TF91) 
Soojung  
Electronics Ind 
CLT9Z087ZE 
Class B (130 °C) 
IEC 60065 
clause 14.3 
1.) 
Bobbin Mtl. 
Momentive 
PF2736(a)(b) 
V-0, 150°C, PF 
UL94 UL, 
E61040 
Insulation tape 
Alt.)  
Duck Sung Hitech 
Jingjiang Yahua  
DTS-204& 
PZ 
V-0, 130°C, PET 
V-0, 130°C, PET 
UL510 
UL510 
UL, E105147
UL, E165111
Transformer 
(TF92) 
Soojung  
Electronics Ind 
CLT9Z088ZE 
Class B (130 °C) 
IEC 60065 
clause 14.3 
1.) 
Bobbin Mtl. 
Momentive 
PF2736(a)(b) 
V-0, 150°C, PF 
UL94 UL, 
E61040 
Insulation tape 
Alt.)  
Duck Sung Hitech 
Jingjiang Yahua  
DTS-204& 
PZ 
V-0, 130°C, PET 
V-0, 130°C, PET 
UL510 
UL510 
UL, E105147
UL, E165111
Transformer 
(TF93) 
Seoul Electronics & 
Telecom Co Ltd. 
CLT9Z089ZE 
Class B (130 °C) 
IEC 60065 
clause 14.3 
1.) 
Bobbin Mtl. 
Chang Chun 
T375HF 
V-0, 150°C, PMC 
UL94 UL, 
E59481 
Insulation tape 
Alt.)  
Alt.) 
Duck Sung Hitech 
Jingjiang Yahua  
Shin U Tape 
DTS-204& 
CT 
SU26* 
V-0, 130°C, PET 
V-0, 130°C, PET 
V-0, 130°C, PET 
UL510 
UL510 
UL510 
UL, E105147
UL, E165111
UL, E215155
*) A various suitable certified power supply cord set can be added in the country where the apparatus is sold. 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to IEC 60065:2001 (Seventh Edition) + am1:2005 + am2:2010 
 
Page 48 of 50 
Report No.: 232173 
  
TRF No. IEC60065K 
 
14 
TABLE: list of critical components and materials – (continue) 
Object / part 
No. 
Manufacturer/ 
trademark 
Type / model
Technical data 
Standard 
Approval/ 
Ref. *) 
Line filter  
(LF91, LF92) 
Seoul Electronics & 
Telecom Co Ltd. 
CLZ9Z135Z 
105 °C 
IEC 60065 
1.) 
Bobbin Mtl. 
Chang Chun 
4130(100%Virgin) 
(a)(b)
 
V-0, 120°C, PBT 
UL94 
UL, E59481 
Coil Base 
Chang Chun 
T375HF 
V-0, 150°C, PMC 
UL94 
UL, E59481 
Line filter 
(LF93) 
Kwang Sung 
Electronics Co. Ltd. 
CLZ9Z121Z 
105 °C 
IEC 60065 
1.) 
Coil Base 
Alt.) 
Alt.) 
Sumitomo Bakelite 
Chang Chun  
Momentive Specialty
 
PM8375 
T-355J  
PF2736(a)(b) 
V-0, 150°C, PF 
V-0, 150°C, PMC 
V-0, 150°C, PF 
UL94 
UL94 
UL94 
UL, E41429 
UL, E59481 
UL, E61040 
X-capacitor  
(CX91) 
Alt.) 
 
Alt.) 
Carli Electronics 
 
Seoryoung 
Electronics (H.K.) 
Okaya Electric 
MPX 
 
MPX-X2 
 
RE 
0.22 µF / 275V~ 
X2 
IEC 60384-14  VDE 
 
VDE 
 
VDE 
X-capacitor  
(CX92) 
Alt.) 
 
Alt.) 
Carli Electronics 
 
Seoryoung 
Electronics (H.K.) 
Okaya Electric 
MPX 
 
MPX-X2 
 
RE 
0.33 µF / 275V~ 
X2 
IEC 60384-14  VDE 
 
VDE 
 
VDE 
Y-capacitor  
(CY91, CY92, 
CY96) 
Alt.) 
Alt.) 
PT. SAMCON 
 
 
Murata Mfg. 
Apex Intec 
SD 
 
 
KX 
NK 
1500 pF, 
Min. 250V~, 
Y1 
IEC 60384-14  FKMKO 
 
 
VDE 
VDE 
Y-capacitor  
(CY95) 
Alt.) 
Alt.) 
PT. SAMCON 
 
Murata Mfg. 
Apex Intec 
SD 
 
KX 
NK 
1000 pF, 
Min. 250V~, 
Y1 
IEC 60384-14  FKMKO 
 
VDE 
VDE 
Bridging cap. 
(CY93, CY94) 
Alt.) 
Alt.) 
PT. SAMCON 
 
Murata Mfg. 
Apex Intec 
SD 
 
KX 
NK 
1000 pF, 
Min. 250V~, 
Y1 
IEC 60384-14  FKMKO 
 
VDE 
VDE 
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to IEC 60065:2001 (Seventh Edition) + am1:2005 + am2:2010 
 
Page of 106
Display

Click on the first or last page to see other AVR 151 (serv.man5) service manuals if exist.