Harman Kardon AVR 151 (serv.man5) EMC - CB Certificate ▷ View online
Page 45 of 50
Report No.: 232173
TRF No. IEC60065K
14.3.3 Transformer/motor,
constructional
requirements
P
Transformer
Part No.
Part No.
Insulation
between
between
Insulation
Res.
M Ohms
Test Volt
V (60 sec.)
Clearances / Creepage
distances
Measured
Required
TF91 (CLT9Z087ZE)
Pr. - Sec.
> 5.2
3000 Vac
6.0 / 6.0
4.6 / 5.0
TF92 (CLT9Z088ZE)
Pr. - Sec.
> 5.2
3000 Vac
6.5 / 6.5
4.6 / 6.0 *)
TF93 (CLT9Z089ZE)
Pr. - Sec.
> 5.2
3000 Vac
7.0 / 7.0
4.4 / 6.4
*) Liner interpolation applied for creepage distances
-
Components / construction
TF91 (CLT9Z087ZE)
TF91 (CLT9Z087ZE)
Windings on single bobbin.
Three (3) layers of insulation used between primary
winding and iron core / secondary winding.
Satisfactory constructed. Bobbin thickness: > 0,4mm.
Three (3) layers of insulation used between primary
winding and iron core / secondary winding.
Satisfactory constructed. Bobbin thickness: > 0,4mm.
#) Max. working voltage: 585Vpeak / 245Vrms
P
-
Components / construction
TF92 (CLT9Z088ZE)
TF92 (CLT9Z088ZE)
Windings on single bobbin.
Three (3) layers of insulation used between primary
winding and secondary winding.
Satisfactory constructed. Bobbin thickness: > 0,4mm.
Three (3) layers of insulation used between primary
winding and secondary winding.
Satisfactory constructed. Bobbin thickness: > 0,4mm.
#) Max. working voltage: 640Vpeak / 280Vrms
P
-
Components / construction
TF93 (CLT9Z089ZE)
TF93 (CLT9Z089ZE)
Windings on single bobbin.
Three (3) layers of insulation used between primary
winding and iron core / secondary winding
Satisfactory constructed. Bobbin thickness: > 0,4mm.
Three (3) layers of insulation used between primary
winding and iron core / secondary winding
Satisfactory constructed. Bobbin thickness: > 0,4mm.
#) Max. working voltage: 560Vpeak / 260Vrms
P
#) Measured highest working voltage for transformer between primary and secondary.
Page 46 of 50
Report No.: 232173
TRF No. IEC60065K
Transformer
Part No
Part No
Insulation
Between
Thick (mm)
X Number
Material
Dielectric strength test
/ 60 sec.
TF91
(CLT9Z087ZE)
(CLT9Z087ZE)
Pr. – ic.
0.60 mm min
Phenolic bobbin
Pass *)
Pr. – ic.
0.025 mm min. x 3
Ployester film tape
2 layers tested – Pass *)
Pr. – sec.
0.025 mm min. x 3
Ployester film tape
2 layers tested – Pass *)
TF92
(CLT9Z088ZE)
(CLT9Z088ZE)
Pr. – ic.
0.70 mm min
Phenolic bobbin
Pass *)
Pr. – sec.
0.025 mm min. x 3
Ployester film tape
2 layers tested – Pass *)
TF93
(CLT9Z089ZE)
(CLT9Z089ZE)
Pr. – ic.
0.70 mm min
Phenolic bobbin
Pass *)
Pr. – ic.
0.025 mm min. x 3
Ployester film tape
2 layers tested – Pass *)
Pr. – sec.
0.025 mm min. x 3
Ployester film tape
2 layers tested – Pass *)
*) Test voltage: 3000 Vrms
17.1
Torque test to Table 20:
P
Screw
Location / function
Location / function
Diameter
(mm)
(mm)
With
Head
Without
Head
Material
Torque test (Nm)
Fulfilled / Remarks
Screw
Nut
Fixing of top cover
(side)
(side)
4.0
X
-
Metal
Metal
1.2 Nm, 5 times / Pass
4.0
X
-
Metal
Plastic
1.2 Nm, 10 times / Pass
Fixing of top cover
(rear)
(rear)
3.0
X
-
Metal
Metal
0.5 Nm, 5 times / Pass
Page 47 of 50
Report No.: 232173
TRF No. IEC60065K
14
TABLE: list of critical components and materials
P
Object / part
No.
No.
Manufacturer/
trademark
Type / model
Technical data
Standard
Approval/
Ref. **)
Mains cord set
(For CENELEC
countries) *)
(For CENELEC
countries) *)
Volex (Asia) Pte
Ltd
Ltd
M3204
H05VV-F
VAC17S
H05VV-F
VAC17S
10/16A, 250V
0.75 mm
0.75 mm
2
x 2
10A/250V
IEC60884-1
IEC60227
IEC60320
IEC60227
IEC60320
VDE
VDE
VDE
VDE
VDE
Alt.)
Kenic Electric Mfg.
Co., Ltd.
Co., Ltd.
KE-25
H05VV-F
KE-48
H05VV-F
KE-48
16A, 250V
0.75 mm
0.75 mm
2
x 2
10A/250V
IEC60884-1
IEC60227
IEC60320
IEC60227
IEC60320
VDE
VDE
VDE
VDE
VDE
Mains cord set
(For China)
*)
(For China)
*)
Volex (Asia) Pte Ltd V301C
RVV 300/500
VAC17S
10A/250V
1.0 mm
1.0 mm
2
x 2
10A/250V
GB1002
GB2009
GB5023.5
GB17465.1
GB2009
GB5023.5
GB17465.1
CQC
CQC
CQC
CQC
CQC
Mains cord set
(For UK and
Singapore)
*)
(For UK and
Singapore)
*)
Volex (Asia) Pte Ltd MP5004
MP5004A
H05VV-F
VAC17S
H05VV-F
VAC17S
13A/250V
0.75 mm
0.75 mm
2
x 2
10A/250V
BS1363
SS145
BS6500
YEC60320
SS145
BS6500
YEC60320
ASTA, PSB
ASTA, PSB
ASTA
VDE
ASTA, PSB
ASTA
VDE
Appliance inlet
Rich Bay Co., Ltd. R-301(21)
15A/250V
IEC 60320
VDE
AC connector
(CN90)
Yeon Ho
electronics
electronics
YW396 series
Min. 5A/250V~
IEC 60065
UL 1977
UL 1977
1.)
UL, E108706
UL, E108706
Mains fuse
(F901)
(F901)
Littelfuse Inc
215
T6.3A H 250V
IEC 60127
VDE
Transformer
(TF91)
(TF91)
Soojung
Electronics Ind
Electronics Ind
CLT9Z087ZE
Class B (130 °C)
IEC 60065
clause 14.3
clause 14.3
1.)
Bobbin Mtl.
Momentive
PF2736(a)(b)
V-0, 150°C, PF
UL94 UL,
E61040
Insulation tape
Alt.)
Alt.)
Duck Sung Hitech
Jingjiang Yahua
Jingjiang Yahua
DTS-204&
PZ
PZ
V-0, 130°C, PET
V-0, 130°C, PET
V-0, 130°C, PET
UL510
UL510
UL510
UL, E105147
UL, E165111
UL, E165111
Transformer
(TF92)
(TF92)
Soojung
Electronics Ind
Electronics Ind
CLT9Z088ZE
Class B (130 °C)
IEC 60065
clause 14.3
clause 14.3
1.)
Bobbin Mtl.
Momentive
PF2736(a)(b)
V-0, 150°C, PF
UL94 UL,
E61040
Insulation tape
Alt.)
Alt.)
Duck Sung Hitech
Jingjiang Yahua
Jingjiang Yahua
DTS-204&
PZ
PZ
V-0, 130°C, PET
V-0, 130°C, PET
V-0, 130°C, PET
UL510
UL510
UL510
UL, E105147
UL, E165111
UL, E165111
Transformer
(TF93)
(TF93)
Seoul Electronics &
Telecom Co Ltd.
Telecom Co Ltd.
CLT9Z089ZE
Class B (130 °C)
IEC 60065
clause 14.3
clause 14.3
1.)
Bobbin Mtl.
Chang Chun
T375HF
V-0, 150°C, PMC
UL94 UL,
E59481
Insulation tape
Alt.)
Alt.)
Alt.)
Alt.)
Duck Sung Hitech
Jingjiang Yahua
Shin U Tape
Jingjiang Yahua
Shin U Tape
DTS-204&
CT
SU26*
CT
SU26*
V-0, 130°C, PET
V-0, 130°C, PET
V-0, 130°C, PET
V-0, 130°C, PET
V-0, 130°C, PET
UL510
UL510
UL510
UL510
UL510
UL, E105147
UL, E165111
UL, E215155
UL, E165111
UL, E215155
*) A various suitable certified power supply cord set can be added in the country where the apparatus is sold.
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to IEC 60065:2001 (Seventh Edition) + am1:2005 + am2:2010
Page 48 of 50
Report No.: 232173
TRF No. IEC60065K
14
TABLE: list of critical components and materials – (continue)
P
Object / part
No.
No.
Manufacturer/
trademark
Type / model
Technical data
Standard
Approval/
Ref. *)
Line filter
(LF91, LF92)
(LF91, LF92)
Seoul Electronics &
Telecom Co Ltd.
Telecom Co Ltd.
CLZ9Z135Z
105 °C
IEC 60065
1.)
Bobbin Mtl.
Chang Chun
4130(100%Virgin)
(a)(b)
(a)(b)
V-0, 120°C, PBT
UL94
UL, E59481
Coil Base
Chang Chun
T375HF
V-0, 150°C, PMC
UL94
UL, E59481
Line filter
(LF93)
(LF93)
Kwang Sung
Electronics Co. Ltd.
Electronics Co. Ltd.
CLZ9Z121Z
105 °C
IEC 60065
1.)
Coil Base
Alt.)
Alt.)
Alt.)
Alt.)
Sumitomo Bakelite
Chang Chun
Chang Chun
Momentive Specialty
PM8375
T-355J
PF2736(a)(b)
T-355J
PF2736(a)(b)
V-0, 150°C, PF
V-0, 150°C, PMC
V-0, 150°C, PF
V-0, 150°C, PMC
V-0, 150°C, PF
UL94
UL94
UL94
UL94
UL94
UL, E41429
UL, E59481
UL, E61040
UL, E59481
UL, E61040
X-capacitor
(CX91)
Alt.)
Alt.)
(CX91)
Alt.)
Alt.)
Carli Electronics
Seoryoung
Electronics (H.K.)
Okaya Electric
Seoryoung
Electronics (H.K.)
Okaya Electric
MPX
MPX-X2
RE
MPX-X2
RE
0.22 µF / 275V~
X2
X2
IEC 60384-14 VDE
VDE
VDE
X-capacitor
(CX92)
Alt.)
Alt.)
(CX92)
Alt.)
Alt.)
Carli Electronics
Seoryoung
Electronics (H.K.)
Okaya Electric
Seoryoung
Electronics (H.K.)
Okaya Electric
MPX
MPX-X2
RE
MPX-X2
RE
0.33 µF / 275V~
X2
X2
IEC 60384-14 VDE
VDE
VDE
Y-capacitor
(CY91, CY92,
CY96)
Alt.)
Alt.)
(CY91, CY92,
CY96)
Alt.)
Alt.)
PT. SAMCON
Murata Mfg.
Apex Intec
Murata Mfg.
Apex Intec
SD
KX
NK
KX
NK
1500 pF,
Min. 250V~,
Y1
Min. 250V~,
Y1
IEC 60384-14 FKMKO
VDE
VDE
Y-capacitor
(CY95)
Alt.)
Alt.)
(CY95)
Alt.)
Alt.)
PT. SAMCON
Murata Mfg.
Apex Intec
Murata Mfg.
Apex Intec
SD
KX
NK
KX
NK
1000 pF,
Min. 250V~,
Y1
Min. 250V~,
Y1
IEC 60384-14 FKMKO
VDE
VDE
Bridging cap.
(CY93, CY94)
Alt.)
Alt.)
(CY93, CY94)
Alt.)
Alt.)
PT. SAMCON
Murata Mfg.
Apex Intec
Murata Mfg.
Apex Intec
SD
KX
NK
KX
NK
1000 pF,
Min. 250V~,
Y1
Min. 250V~,
Y1
IEC 60384-14 FKMKO
VDE
VDE
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to IEC 60065:2001 (Seventh Edition) + am1:2005 + am2:2010
Click on the first or last page to see other AVR 151 (serv.man5) service manuals if exist.