Page 25 of 50 
Report No.: 232173 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
 
N/A 
15.3.2 
Reliable connection of non-detachable cords  
 
N/A 
 
Not soldered to conductors of a printed circuit board   
N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
 
N/A 
 
Wire secured by additional means to the  
conductor   
No screws and nuts clamping 
conductors used. 
N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
No such terminal used. 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 
N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16   
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
 
N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand  
 
N/A 
15.4 
Devices forming a part of the mains plug  
No devices forming a part of  
the mains plug. 
N/A 
15.4.1 
No undue strain on mains socket-outlets  
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 
N/A 
 
Page 26 of 50 
Report No.: 232173 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
16 
External flexible cords 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ............................................................ : 
Sheathed PVC cord complying 
with IEC 60227 (GB5023.5  
for China). 
 
See appended table, list of 
critical components. 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
Class II apparatus 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
The cord is min 0.75 mm² 
within the current rating. 
 
See appended table, list of 
critical components 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
No interconnecting cords. 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2) 
No interconnecting cords. 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
No interconnecting cords. 
N/A 
16.5 
Adequate strain relief on external flexible cords  
Appliance inlet provided 
N/A 
 
Not possible to push cord back into equipment  
 
N/A 
 
Strain relief device unlikely to damage flexible  
cord  
 
N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor 
Class II equipment 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use  
Appliance inlet provided 
N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1  
The apparatus is not a  
transportable musical  
instrument and amplifier 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord  
 
N/A 
 
Page 27 of 50 
Report No.: 232173 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
17 
Electrical connections and mechanical fixings 
 
17.1 
Torque test to table 20  
See below 
 
- screws into metal: 5 times  
(see appended table 17.1) 
 
- screws into non-metallic material: 10 times  
(see appended table 17.1) 
17.2 
Correct introduction into female threads in non-
metallic material  
Correct introduction of screws  
into non-metallic material for  
top cover. 
17.3 
Cover fixing screws: captive  
Captivity not necessary 
N/A 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter  
Tested with screw with 
10 times diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A  
Loosening is sufficiently 
prevented. 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A  
No contact pressure 
transmitted through insulating 
material. 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder  
No such screw terminals. 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous  
No cover fixing devices 
other than screws 
N/A 
17.8 
Fixing devices for detachable legs or stands  
provided  
No detachable legs or stands 
provided. 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected  
Connections comply, 
checked by inspection. 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
 
18.1 
Picture tube separately approved to IEC 61965  ... :  No picture tube used 
N/A 
 
Picture tube separately approved to 18.2  .............. :   
N/A 
18.2 
Non-intrinsically protected tubes tested to 18.2 
 
N/A 
 
19 
Stability and mechanical hazards 
 
 
Mass of the equipment exceeding 7 kg  ................. : 
Mass: 4.52 kg 
 
 
Apparatus intended to be fastened in place – 
suitable instructions  ................................................ : 
No  
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal  
 
N/A 
19.2 
100 N force applied vertically downwards  
 
N/A 
19.3 
100 N force, or 13% of weight, applied horizontally to 
point of least stability  
Mass: < 25 kg or < 1 m 
N/A 
Page 28 of 50 
Report No.: 232173 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
19.4 
Edges or corners not hazardous  
There are no hazardous 
edges or corners when the 
apparatus is operating in 
normal position. 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension > 450 mm, 
pass the test of 19.5.1  
No glass surface. 
N/A 
19.6 
Wall or ceiling mountings adequate  
No wall or ceiling mountings 
N/A 
 
20 
Resistance to fire 
 
20.1 
Electrical components and mechanical parts  
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
 
N/A 
 
b) Exemption for small components as defined in 
20.1  
PCB is of flammability class 
V-0, and exception is made  
for small components. 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4  
Electrical components  
comply with flammability 
requirements in clause 14. 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
No wires working at 
voltages > 4kV or leaving 
an internal fire enclosure. 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure 
All PCB are of base material 
with flammability category 
V-0 (UL approved),  
See list of critical components. 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
No voltage > 400 V (peak) 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 20.1.2 
and 20.1.3 (other than fire enclosures) mounted 
nearer to a potential ignition source than the 
distances in Table 21 comply with the relevant 
flammability category in Table 21  
Bobbin (base) of transformers 
and Line filters are complying 
with the relevant flammability 
category in Table 21. 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
No such components 
N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
Normal operating voltage  
< 4kV 
N/A 
Page of 106