Harman Kardon AVR 151 (serv.man5) EMC - CB Certificate ▷ View online
Page 9 of 50
Report No.: 232173
TRF No. IEC60065K
Name and address of factory (ies):
Factory 1:
Anam Electronics (Dongguan) Co., Ltd.
Xin Cheng Management Area, LiaoBu Town, DongGuan City,
GuangDong Province, China.
Anam Electronics (Dongguan) Co., Ltd.
Xin Cheng Management Area, LiaoBu Town, DongGuan City,
GuangDong Province, China.
Factory 2:
DongGuan LiaoBu Anam Electronics.
Xin Cheng Management Area, LiaoBu Town, DongGuan City,
GuangDong Province, China.
General product information:
The apparatus under test is A/V Surround Receiver of insulation Class II
The apparatus has amplifier circuits (Front, Surround and Center), Tuner Circuit, Several signal in/out
(RCA, COAXIAL, OPTICAL, NETWORK, Mini jacks, HDMI, Phones and USB) terminals and Speaker
terminals - (See also photos)
The model, AVR 151/230 is basic model.
The model, AVR 151/230C is identical to tested basic model except for model designation with marking
drawing and marketing region.
The apparatus under test is A/V Surround Receiver of insulation Class II
The apparatus has amplifier circuits (Front, Surround and Center), Tuner Circuit, Several signal in/out
(RCA, COAXIAL, OPTICAL, NETWORK, Mini jacks, HDMI, Phones and USB) terminals and Speaker
terminals - (See also photos)
The model, AVR 151/230 is basic model.
The model, AVR 151/230C is identical to tested basic model except for model designation with marking
drawing and marketing region.
Page 10 of 50
Report No.: 232173
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
3 General
requirements
Safety class of the apparatus .................................. : Class II apparatus
P
4
General test conditions
4.1.4
Ventilation instructions require the use of the test
box
box
Tested in a wooden test box
according to instructions in
user manual.
(Tested box condition: 30 cm
for top and other sides)
according to instructions in
user manual.
(Tested box condition: 30 cm
for top and other sides)
P
5
Marking and instructions
Comprehensible and easily discernible
On front and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / petroleum
sprit
sprit
P
5.1 a)
Identification,
maker ............................................ : Trade mark:
P
b) Model number or type reference .......................... : Model no.:
AVR 151/230, or
AVR 151/230C
See copy of marking plate.
AVR 151/230C
See copy of marking plate.
P
c) Class II symbol if applicable ................................ : Class II symbol is applied in
according to IEC 60417-5172.
P
d) Nature of supply ................................................... : a.c. symbol is applied in
according to IEC 60417-5032
P
e) Rated supply voltage ........................................... : 220-240 V~
P
f) Mains frequency if safety dependant ................... : 50/60 Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ............................................................................ :
apparatus supplied by supply apparatus for general
use ............................................................................ :
The apparatus is connection
to an a.c. mains supply
to an a.c. mains supply
N/A
Measured current or power consumption ............... :
N/A
Deviation
%
(max 10%) ........................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
210 W
P
Measured current or power consumption ............... : Max. 173.7 W
(see appended table 7.1)
P
Measured current or power consumption for
Television set ........................................................... :
Television set ........................................................... :
No television set.
N/A
Deviation
%
(max
10%) ........................................... : Not exceed the marked value
P
Page 11 of 50
Report No.: 232173
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
5.2
a) Earth terminal
Class II apparatus
N/A
b) Hazardous live terminals
No hazardous live terminals.
The output signal will rise to
17.1 Vp at maximum out
power if the speaker load is
disconnected in the speaker
terminal, No hazard.
The output signal will rise to
17.1 Vp at maximum out
power if the speaker load is
disconnected in the speaker
terminal, No hazard.
P
c) Markings on supply output terminals
No socket outlet for providing
power to other apparatus
except USB terminal.
“5V/2.1A
power to other apparatus
except USB terminal.
“5V/2.1A
” marked for
USB output terminal.
P
5.3
a) Use of triangle with exclamation mark
Correct symbol applied:
- In rear side in connection
with CAUTION of opening
- In circuit diagram.
Further, no incorrect use of
this symbol is found.
- In rear side in connection
with CAUTION of opening
- In circuit diagram.
Further, no incorrect use of
this symbol is found.
P
b) marking on loudspeaker grille, IEC 60417-5036
Not used loudspeaker grille
N/A
5.4
Instructions for use
User information in the
following language:
English and Chinese.
See comments in Summary
of Testing.
following language:
English and Chinese.
See comments in Summary
of Testing.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
The user manual includes
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
P
b) Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
c) Instructions for replacing lithium battery
No battery
N/A
d) Class I earth connection warning
Class II apparatus
N/A
e) Instructions for multimedia system connection
Instructions for multimedia
system connection provided
in user manual.
system connection provided
in user manual.
P
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
No such equipment
N/A
g) Warning: battery exposure to heat
No such equipment
N/A
h) Warning: protective film on CRT face
No CRT
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Appliance coupler is
disconnecting device and
readily operable.
disconnecting device and
readily operable.
P
Page 12 of 50
Report No.: 232173
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
c) Instructions for permanently connected equipment Not permanently connected
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
Information provided in user
manual.
manual.
P
6 Hazardous
radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
................................................................................... :
................................................................................... :
No laser radiation
N/A
Emission limits under fault conditions ..................... :
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
No fuse links operate during
normal operating operation.
(see appended table 7.1)
normal operating operation.
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Appliance inlet is certified by
IEC/EN 60320-1.
Bobbins for transformer/ Line
filter (base) are made of
Phenolic.
See appended Table 7.2 for
AC connector (wafer) CN90
IEC/EN 60320-1.
Bobbins for transformer/ Line
filter (base) are made of
Phenolic.
See appended Table 7.2 for
AC connector (wafer) CN90
P
8
Constructional requirements with regard to the protection against electric
shock
shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation ”By hand” not
possible
possible
N/A
Click on the first or last page to see other AVR 151 (serv.man5) service manuals if exist.