Harman Kardon AVR 151 (serv.man4) EMC - CB Certificate ▷ View online
ELECTRONICS CO.,LTD.
645,SUNGKOK-DONG,ANSAN-CITY,KYUNGKI-DO,425-834,KOREA
Fax:+82-31-490-2539 Tel:+82-31-490-2283
Fax:+82-31-490-2539 Tel:+82-31-490-2283
EMS TEST REPORT
Reference No. 54121302D
Equipment Under Test
Equipment
: AV Receiver
Type/model :
AVR151/230
Brand Name
: Harman/Kardon
Manufacturer
: Harman International Industries, Incorporated
Total Page of this report : 32(including this page)
Immunity to electromagnetic disturbances
Total Page of this report : 32(including this page)
SUMMARY
Referring to the performance criteria and the operating mode during the tests specified
in this report the equipment does comply with the requirements according to
EN55020(2007)&+A11(2011). The test results in this report apply only to the sample tested.
Report Issued : February 19, 2013
EUT Received : February 5, 2013
Tested by :
Approved by :
B. S. Lee /Researching Engineer
H. S. Seol / General Manager
" This report should not be reproduced except in full without the written approval of the testing laboratory."
◀
Anam EMC Test Laboratory ▶
Reference No.: 54121302D
Page 2/32
CONTENTS
Page
1. Client information
3
2. Equipment under test (EUT)
3
2.1 Identification of the EUT
2.2 Additional information about the EUT
3. Test specifications
4
3.1 Standards
3.2 Additions,deviations and exclusions from standards
3.3 Purpose of the test
4. Test summary
4
5. Input immunity to RF voltages(in differential mode):S1
5
5.1 Test criteria and test procedure
5.2 Measurement uncertainty
5.3 Test result
6. Immunity to RF voltages:S2a
6
6.1 Test criteria and test procedure
6.2 Measurement uncertainty
6.3 Test result
7. Immunity to RF voltages (in common mode):S2b
7
7.1 Test criteria and test procedure
7.2 Measurement uncertainty
7.3 Test result
8. Immunity to ambient electromagnetic fields:S3
8
8.1 Test criteria and test procedure
8.2 Measurement uncertainty
8.3 Test result
9. Screening effectiveness:S4
9
9.1 Test criteria and test procedure
9.2 Measurement uncertainty
9.3 Test result
10. Test instrumentation
10
Annex-Measurement Data;
Annex A
: Input immunity to RF voltages(in differential mode)
11
Annex B
: Immunity to RF voltage 17
Annex C
: Immunity to RF voltage(in common mode)
28
Annex D
: Immunity to ambient electromagnetic fields
30
Annex E
: Screening effectiveness
32
◀
Anam EMC Test Laboratory ▶
Reference No.: 54121302D
Page 3/32
1. CLIENT INFORMATION
The EUT has been test by request of:
* Company
: Harman International Industries, Incorporated
8500 Balboa Blvd., Northridge, CA 91329, USA
8500 Balboa Blvd., Northridge, CA 91329, USA
* Contact Person
: Mr. Tim Huang (Sr Compliance Engineer)
Mr. Aaron Butters
Mr. Aaron Butters
* Tel.
: +86 755 8634 3778 / +1 818 895 3312
2. EQUIPMENT UNDER TEST(EUT)
2.1 Identification of the EUT
*Equipment
: AV Receiver
*Model No.
: AVR151/230
*Brand Name
: Harman/Kardon
*Serial No.
: AN0146-0000010
*Manufacturer
: Harman International Industries, Incorporated
8500 Balboa Blvd., Northridge, CA 91329, USA
8500 Balboa Blvd., Northridge, CA 91329, USA
*Power Rating
AC 220-240V, 50/60Hz, 210W
*External signal
SPEAKER L, R, SL, SR, C
In/Out terminal
AUDIO : ANALOG 1, 2, SUBWOOFER OUT
VIDEO : VIDEO 1,2, MONITOR OUT
HDMI : 1,2,3,4, MONITOR OUT
Optical 1, COAXIAL, IR IN, TRIGGER OUT
PHONES, USB
VIDEO : VIDEO 1,2, MONITOR OUT
HDMI : 1,2,3,4, MONITOR OUT
Optical 1, COAXIAL, IR IN, TRIGGER OUT
PHONES, USB
*Tuner Section
: FM 87.5㎒ ~ 108㎒ (50㎑ Steps)
: AM 522㎑ ~ 1,620㎑ (9㎑ Steps)
: AM 522㎑ ~ 1,620㎑ (9㎑ Steps)
2.2 Additional information about the EUT
The EUT consists of the following subsystems/modules/parts; none
The tests have been performed on the EUT provided with the following
modifications; none
The tests have been performed on the EUT provided with the following
modifications; none
◀
Anam EMC Test Laboratory ▶
Reference No.: 54121302D
Page 4/32
3. TEST SPECIFICATIONS
3.1 Standards
EN55020(2007)&+A11(2011)
Sound and television broadcast receivers and associated equipment
- Immunity characteristics - Limits and methods of measurement
Sound and television broadcast receivers and associated equipment
- Immunity characteristics - Limits and methods of measurement
3.2 Additions,deviations and exclusions from standards
No additions,deviations or exclusions have been made from standard.
3.3 Purpose of the test
Purpose of test: To determine whether the equipment under test fulfils the
EMC immunity requirements of the standard stated in section 3.1
EMC immunity requirements of the standard stated in section 3.1
4. TEST SUMMARY
The results in this report apply only to sample tested:
Passed
the test
Note
(S1)Input immunity to RF voltages
Yes
(S2a)Immunity to RF voltages
Yes
(S2b)Immunity to RF voltages(in common mode)
Yes
(S3)Immunity to ambient electromagnetic fields
Yes
(S4)Screening effectiveness
Yes
Note : * N.A. = Not Applicable
The equipment does comply with the requirements
Measurement data see annex A,B,C,D and E.
◀
Anam EMC Test Laboratory ▶