Page 17 of 50 
Report No.: 232173 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 
N/A 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm²  ............... :
No area where temperature 
exceeds 100K above limits 
N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min 
No area where temperature 
exceeds 300K above limits 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
No conductors are 
interrupted/peeled/loosened 
during fault conditions 
N/A 
 
Class I protective earthing maintained  
Class II equipment 
N/A 
11.2.7 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.6 shall not exceed the limits in table 3, 
item e), "Fault conditions". 
(see appended table 11.2) 
 
12 Mechanical 
strength 
 
12.1.1 
Bump test where mass >7 kg  
Mass: 4.52 kg 
N/A 
12.1.2 
Vibration test  
Assessed to be 
satisfactory constructed 
12.1.3 
Impact hammer test  
No damage in the sense of 
this standard. 
 
Steel ball test  
No damage in the sense of 
this standard. 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg  No portable apparatus 
N/A 
12.1.5 
Thermoplastic enclosures stress relief test  
No risk of shrinkage or 
distortion on enclosure 
12.2 
Fixing of knobs, push buttons, keys and levers  
Normal use will not impair  
the protection against 
electric shock 
12.3 
Remote controls with hazardous live parts  
No remote control containing 
hazardous live parts 
N/A 
12.4 
Drawers (pull test 50 N, 10 s)  
No drawers 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
No such antenna coaxial 
sockets 
N/A 
12.6 
Telescoping or rod antennas construction  
No telescoping or rod 
antennas 
N/A 
12.6.1 
Telescoping or rod antennas securement  
 
N/A 
 
Page 18 of 50 
Report No.: 232173 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
13 
Clearances and creepage distances 
 
13.1 
Clearances in accordance with 13.3  
See 13.3 
 
Creepage distances in accordance with 13.4  
See 13.4 
13.2 
Determination of working voltage  
Conventional transformer 
used.  Upper rated supply 
voltage (240V) applied in 
determining the working 
voltage 
13.3 Clearances 
 
2N for internal parts and 30N 
for enclosure are considered 
when determining clearances 
13.3.1 General 
 
Considered 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 ............. : 
(see appended table 13) 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
No hazardous secondary 
voltages 
N/A 
13.3.4 
Measurement of transient voltages  
No measurement of transient 
voltages 
N/A 
13.4 
Creepage distances  
CTI > 100 
(see appended table 13) 
 
Creepage distances greater than table 11 minimum 
values  
Not applicable 
N/A 
13.5 
Printed boards  
Refer to below 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
No such PCB used 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
No type B coated printed circuit 
boards 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
Jointed insulation not applied. 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 
N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
No such part used 
N/A 
Page 19 of 50 
Report No.: 232173 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
Approved optocoupler. 
See appended table, list of 
critical components. 
 
14 Components 
 
14.1 Resistors 
 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
No such resistors 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
Bleeder resistor, RX93. 
(Connected in series between 
Live and Neutral after mains 
fuse, certified component by 
VDE) 
See appended table, list of 
critical components 
 Resistors 
separately approved  .............................. : 
RX93. 
See appended table, list of 
critical components 
14.2 
Capacitors and RC units  
 
 
Capacitors separately approved  : 
Yes, see below 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
CY91, CY92, CY93, CY94, 
CY95 and CY96 certified 
according to IEC 60384-14 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
CX91 and CX92 certified 
according to IEC 60384-14 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... : 
No such capacitors 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC 60384-1, 4.38 category B or better  ................. : 
Several E. cap. Exceeding 
volume 1750mm
3
, but metal 
cases. 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better   ................................................ : 
Several E. cap. Exceeding 
volume 1750mm
3
, but metal 
cases. 
N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal  ....................................................................... : 
 
N/A 
14.3 
Inductors and windings  
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
Transformers evaluated 
according to 14.3.3, 14.3.4 
and 14.3.5. 
P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ............................... : 
Adequate marking applied. 
Mfr, ID and type no. 
Page 20 of 50 
Report No.: 232173 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
 
Transformers and inductors separately approved  . : 
No 
N/A 
14.3.2 General 
 
Isolating transformers 
 
Insulation material complies with clause 20.1.4  
Considered.  The insulation 
material of isolating transf. 
complies with flammability 
category of Table 21. 
14.3.3 
Constructional requirements  
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
(see appended table 13) 
14.3.3.2 Transformers 
meet 
the constructional requirements  (see appended table 14.3.3) 
14.3.4 
Separation between windings 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) .............................. : 
Double or reinforced  
insulation between primary 
and secondary windings 
according to clause 8.8. 
(see appended table 14.3.3) 
 
Coil formers and partition walls > 0,4 mm  
>0.4 mm 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
Transformers are evaluate 
with class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic insulation Windings of Class II 
construction used. 
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
Double or reinforced insulation  
between hazardous live 
windings and accessible 
conductive parts. 
 
Coil formers and partition walls > 0,4 mm  
>0.4 mm 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
Winding of Class II  
construction used. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 
N/A 
14.4 
High voltage components  
No high-voltage components. 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 
N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 