DOWNLOAD Harman Kardon AVR 151 (serv.man5) Service Manual ↓ Size: 5.88 MB | Pages: 106 in PDF or view online for FREE

Model
AVR 151 (serv.man5)
Pages
106
Size
5.88 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-151-sm5.pdf
Date

Harman Kardon AVR 151 (serv.man5) EMC - CB Certificate ▷ View online

Page 41 of 50 
Report No.: 232173 
  
TRF No. IEC60065K 
 
No. 
Component 
Fault 
Duration 
of the test
Other results 
(include description) 
dT (K) / Component 
dT (K) 
Permitted
dT(K) 
51 
*), #) 
D910 
(A to C) 
SC 
10 min 
Normal operated. 
The operating mode changed to 
LOW mode after 2 min 30 s. 
FI stabilised at 0.82 A. 
NCD.  No hazard.  
N/A N/A 
52 
*), #) 
IC91 
(pin 6 to 3) 
SC 
1 s 
F901 fuse opened immediately. 
IC91, D928, R990, D901 and D902 
damaged.  No hazard. 
N/A N/A 
53 
*), #) 
D903 
(A to C) 
SC 
10 min 
Unit shut down after 14 s. 
FI stabilised at 0.06 A. 
NCD.  No hazard.  
N/A N/A 
54 
*), #) 
IC92 
(pin 4 to 2) 
SC 
1 s 
F901 fuse opened.   
IC92 and D916 damaged. 
No hazard.  
N/A N/A 
55 
*), #) 
Surround  
back R Ch. 
output 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
56 
*), #) 
USB output 
(with No 
input signal) 
SC 
10 min 
Only USB output off immediately. 
FI stabilised at 0.32 A. 
NCD.  No hazard.  
N/A N/A 
57 
*), #) 
Abnormal 
operation 
Maximum 
non-
clipped 
output 
signal
 
8 min 
The operating mode changed to 
LOW mode immediately.  
Unit shut down after 8 min by 
operation TS92 thermal protector. 
FI stabilised at 0.06 A.  
Dielectric strength test.  No hazard. 
N/A N/A 
58 
*), #) 
USB output 
5V/3.1A 
Over 
loaded 
4 h 
Normal operated. 
The operating mode changed to 
LOW mode after 2 min 40 min. 
FI stabilised at 0.82 A. 
NCD.  No hazard.  
See #) in the next page
for measured temp. 
59 
*), #) 
Top cover 
opening 
Blocked 
4 h 
Normal operated. 
The operating mode changed to 
LOW mode after 2 min 20 s. 
FI stabilised at 0.82 A. 
Dielectric strength test.  No hazard. 
See ##) in the next 
page for measured 
temp. 
60 
*), #) 
Abnormal 
operation 
Half load  4 h 
Normal operated. 
The operating mode changed to 
LOW mode after 2 min 20 s. 
FI stabilised at 1.70 A. 
Dielectric strength test.  No hazard. 
See ###) in the next 
page for measured 
temp. 
*) Tested voltage 264V 
**) Tested voltage 198V 
Apparatus mode:  
#) HIGH mode 
##) LOW mode 
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current 
 
Page 42 of 50 
Report No.: 232173 
  
TRF No. IEC60065K 
 
Temperature Rise dT of Part
 
dT (K) 
Limit max  
dT (K) 
*) 
Test Condition No. 
#) 
Input test No. 18
##) 
Input test No. 18
###) 
Input test No. 18 
Line filter, LF92 coil 
24.9  
35.1  
26.7  
125 **) 
Line filter, LF91 coil 
24.5  
34.4  
25.9  
125 **) 
Line filter, LF93 coil 
24.4  
32.9  
25.4  
125 **) 
PWB near DB91 
26.5  
34.3  
28.0  
110 
Diode, DB91 body 
33.1  
40.7  
35.1  
PWB near Q901 
31.2  
40.1  
32.5  
110 
FET, Q901 body 
34.3  
46.4  
36.6  
Q901 heat-sink 
33.6  
44.5  
35.7  
Capacitor, C930 body 
25.1  
39.9  
26.7  
105 °C 
AC connector, CN90 body 
21.6  
30.7  
22.4  
Transformer, TF93 coil 
38.4  
58.9  
43.7  
140 **) 
Transformer, TF93 core 
45.1  
57.5  
47.5  
150 
Transformer, TF92 coil 
51.7  
54.7  
49.1  
140 **) 
Transformer, TF92 core 
47.5  
55.8  
45.4  
150 
Transformer, TF91 coil 
33.9  
39.9  
33.6  
140 **) 
Transformer, TF91 core 
32.6  
41.7  
32.8  
150 
PWB near IC1400 
48.9  
58.9  
53.5  
110 
PWB near D952 
49.2  
53.9  
52.5  
110 
Capacitor, C936 body 
29.7  
40.4  
33.0  
105 °C 
IC97 heat-sink 
49.2  
57.8  
49.2  
Capacitor, C915 body 
22.4  
32.0  
24.4  
85 °C 
PWB near Q657 
36.4  
44.6  
43.3  
110 
FET, Q657 body 
45.1  
53.9  
54.0  
Mains heat-sink 
43.1  
53.0  
49.4  
Appliance inlet body 
9.2  
16.9  
9.8  
65 
Standby button surface 
3.2  
5.5  
3.8  
65 
Front cover 
4.9  
7.8  
5.6  
65 
Top enclosure above TF93 
(metallic) 
16.6  
33.0  
17.8  
65 
Top enclosure above Main heat-
sink (metallic)  
28.4 39.6 30.9  65 
Ambient 
19.1 °C 
25.3 °C 
23.3 °C 
*) Temperature rise limits for tropical climate is 10K less. 
**) Minus (-) 10 K applied for thermo-couple method for windings. 
 
 
Page 43 of 50 
Report No.: 232173 
  
TRF No. IEC60065K 
 
13 
TABLES: clearances and creepage distances 
Rated supply voltage: 
240V 
Pollution  degree ... :
Material Group ... : 
IIIb 
2 N force on internal parts applied: 
Yes 
30 N force on outside of conductive enclosure applied: 
Yes 
Location 
Working Voltage 
Clearance (mm) 
Creepage (mm) 
Comm.
 
V rms 
V peak
Min 
Actual 
Min 
Actual 
Across primary directly connected to the mains (B) 
 
 
 
 
 
Live to Neutral 
240 
340 
2.0 
4.0 
2.5 
4.0 
1), 2) 
Live to Neutral 
240 
340 
2.0 
3.1 
2.5 
3.1 
1), 3) 
 
 
 
 
 
 
 
 
Across mains fuse F901 (B) 
240 
340 
2.0 
8.0 
2.5 
8.0 
1) 
 
 
 
 
 
 
 
 
Optocoupler input to output (R) 
 
 
 
 
 
 
PC91 pri. pins to sec. pins 
205 *) 
355 *) 
4.0 
6.7 
5.0 
> 6.7 
1), 4) 
PC92 pri. pins to sec. pins 
205 *) 
355 *) 
4.0 
6.7 
5.0 
6.7 
1) 
PC93 pri. pins to sec. pins 
190 *) 
340 *) 
4.0 
6.7 
5.0 
> 6.7 
1), 4) 
PC94 pri. pins to sec. pins 
210 *) 
355 *) 
4.0 
6.7 
5.0 
> 6.7 
1), 4) 
PC95 pri. pins to sec. pins 
165 *) 
355 *) 
4.0 
8.0 
5.0 
8.0 
1) 
PC96 pri. pins to sec. pins 
205 *) 
355 *) 
4.0 
6.7 
5.0 
> 6.7 
1), 4) 
 
 
 
 
 
 
 
 
Primary to Secondary (R) 
 
 
 
 
 
 
 
CY94 pri. pin to sec. pin 
200 
350 
4.0 
6.5 
5.0 
6.5 
1) 
CY94 pri. pin to TF91 sec. pins 
210 
395 
4.0 
6.0 
5.0 
6.0 
1) 
CY93 pri. pin to sec. pin  
205 
350 
4.0 
6.3 
5.0 
6.3 
1) 
PC92 pin to TF91 pin 5 
205 
350 
4.0 
6.0 
5.0 
6.0 
1) 
CY95 to Sec. GND 
240 
340 
4.0 
7.0 
5.0 
7.0 
1) 
R976 to Sec. GND 
240 
340 
4.0 
7.0 
5.0 
7.0 
1) 
 
 
 
 
 
 
 
 
Primary to accessible conductive parts (R) 
Pri. solder pin to metal chassis 
240 
340 
4.0 
6.8 
5.0 
> 6.8 
5) 
TH91 trace to metal chassis 
240 
340 
4.0 
9.0 
5.0 
9.0 
6) 
 
 
 
 
 
 
 
 
*) 
Measured highest working voltage for optocupler between primary and secondary. 
 
Comments:  1)  Measured on PCB  
2)  Before mains fuse 
3) 
After rated 6.3A mains fuse and before bridge diode (Part of directly connected to the mains).
4)  > 1 mm widths slot provided between insulations. 
5) 
Measured between pri. solder pins and metal chassis (bottom).
 
6)  Measured between TH91 primary trace and metal chassis (back cover inside) 
 
 
Page 44 of 50 
Report No.: 232173 
  
TRF No. IEC60065K 
 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. 
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in 
Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed 
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the 
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an 
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth 
via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from 
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 
or 10 as required, then the value for clearance is used as the minimum creepage distance . 
"Min" = minimum required.
 
"Actual = Actual dimensions measured.
 
 
 
Page of 106
Display