DOWNLOAD Harman Kardon AVR 138 Service Manual ↓ Size: 1.93 MB | Pages: 57 in PDF or view online for FREE

Model
AVR 138
Pages
57
Size
1.93 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-138.pdf
Date

Harman Kardon AVR 138 EMC - CB Certificate ▷ View online

 
 
- Page 21 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
 
Comply with IEC 61051-2 
 
N/A
 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus 
 
N/A
 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 
N/A 
 
 
 
 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard 
Approved mains plug and 
socket-outlet provided,  
see list of critical components.
 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets 
No mains socket outlets
 
N/A 
 
Overloading  of internal wiring prevented if the 
apparatus has mains socket outlets 
No mains socket outlets
 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
P
 
 
No risk of insertion in mains socket-outlets 
Only phone/RCA, Mini jack, 
Optical, Antenna and S-video 
terminals used. Banana plug 
type speaker terminal also 
used, but they are accepted 
due to below note. 
 
Note:  
Banana plug type speaker  
terminals are blocked in their  
axial holes to prevent use of  
plugs that can make permanent 
contact with a mains socket 
outlet. 
 
No risk of insertion into audio or video: outlets marked 
with the symbol of 5.2 
No sockets indicated with the 
symbol 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
Not adaptors used 
N/A 
15.2 
Provision for protective earthing 
N/A
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within equipment
Class II apparatus 
N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
 
- Page 22 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input 
 
N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0,1 
Ω at 25 A  ................... : 
 
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
Apparatus is not for  
permanent connection 
N/A 
15.3.2 
Reliable connection of non-detachable cords: 
 
 
Not soldered to conductors of a printed circuit board 
Not soldered 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
Wires are clamped two times 
to the contact terminal and 
provided with a two-pole  
connector 
 
Wire secured by additional means to the conductor 
Adequately anchored. 
Tested with 5 N. 
15.3.3 
Screws and nuts clamping conductors have adequate 
threads: ISO 261, ISO 262 or similar 
No screws and nuts clamping 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior to 
soldering or held in place by additional means 
No soldered conductors 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws 
Clamped insulators and 
conductors 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment 
Terminals have adequate  
connection capacity. 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16 
 N/A 
15.3.7 
Terminals clamp conductors between metal and have 
adequate pressure 
No clamps. 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided 
 
N/A 
 
 
- Page 23 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
15.3.8 
Terminals carrying a current more than 0,2 A: contact 
pressure not transmitted by insulating material except 
ceramic 
No contact pressure  
transmitted through insulating
 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
The termination of the 
contacts are in adequate  
proximity to each other.
 
 
Terminals located and shielded: test with 8 mm strand
Clamped contacts within  
connector
 
N/A 
15.4 
Devices forming a part of the mains plug 
 
N/A 
15.4.1 
No undue strain on mains socket-outlets 
The apparatus in not a  
device forming a part of the  
mains plug. 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 
N/A 
 
 
 
 
16 
EXTERNAL FLEXIBLE CORDS 
 
16.1 
Mains cords sheathed type, complying with IEC 60227 
for PVC or IEC 60245 for synthetic rubber cords  ....... : 
Sheathed PVC cord complying 
with IEC 60227 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth 
Class II apparatus 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
The cord is 
0.75mm
2
 x2
within the current rating
 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of equipment 
used in combination and carrying hazardous live 
voltages, have adequate dielectric strength 
No interconnecting cables  
comprising hazardous live  
conductors. 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2) 
Cord complying with 16.1. 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
Cords have adequate  
cross-sectional areas to avoid  
temperature rise under normal 
and fault conditions.
  
16.5 
Adequate strain relief on external flexible cords 
Cord clip wedged in the 
enclosure
 
 
 
- Page 24 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
 
Not possible to push cord back into equipment 
Checked by inspection 
 
Strain relief device unlikely to damage flexible cord 
No sharp edges 
 
For mains cords of Class I equipment, hazardous live 
conductors become taut before earth conductor 
Class II apparatus
 
N/A 
16.6 
Apertures for external flexible cord: no risk of damage 
to the cord during assembly or movement in use 
No sharp edges
 
N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1 
The apparatus is not a  
transportable musical  
instrument and amplifier 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 
N/A 
 
 
 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to table 20: 
Screws fixing chassis to the 
main enclosure tested. 
 
- screws into metal: 5 times 
See attachment, Table to  
IEC 60065 7
th
 edition 
 
- screws into non-metallic material: 10 times 
 
N/A 
17.2 
Correct introduction into female threads in non-
metallic material 
No female threads in  
none-metallic materials 
N/A 
17.3 
Cover fixing screws: captive 
Captivity not necessary 
N/A 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter 
Tested with screw with  
10 times diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
Loosening is sufficiently  
prevented. 
17.5 
Contact pressure not transmitted through plastic other 
than ceramic for connections carrying a current 
> 0,2 A 
No contact pressure 
transmitted through insulating 
material. 
17.6 
Stranded conductors of flexible supply cords carrying 
a current > 0,2 A with screw terminals not 
consolidated by solder 
No screw terminals. 
N/A 
17.7 
Cover fixing devices other than screws have adequate 
strength and their positioning is unambiguous 
No cover fixing devices other 
than screws 
N/A 
Page of 57
Display