Harman Kardon AVR 138 EMC - CB Certificate ▷ View online
- Page 17 of 39 -
Report
No.
112419
Transformers and inductors separately approved . :
No
N/A
14.3.2 General
Isolating transformers
P
Insulation material complies with clause 20.1.4
P
14.3.3 Constructional
requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
See attachment, Tables to
IEC 60065 7
IEC 60065 7
th
edition
P
14.3.3.2
Transformers meet the constructional requirements
See attachment, Tables to
IEC 60065 7
IEC 60065 7
th
edition
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between primary and secondary
windings according to clause 8.8
.
between primary and secondary
windings according to clause 8.8
.
See attachment Tables to
IEC 60065 7
IEC 60065 7
th
edition
P
Coil formers and partition walls > 0,4 mm
The main and sub transf.
bobbin fulfils the requirement
of reinforced insulation;
bobbin thickness:
bobbin fulfils the requirement
of reinforced insulation;
bobbin thickness:
≥ 0.4 mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of 14.3.4.2
are met
protective screening only if all 7 conditions of 14.3.4.2
are met
Class II apparatus.
No such transformer used.
No such transformer used.
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm
The main and sub transf.
bobbin fulfils the requirement
of reinforced insulation;
bobbin thickness:
bobbin fulfils the requirement
of reinforced insulation;
bobbin thickness:
≥ 0.4 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Winding of Class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
- Page 18 of 39 -
Report
No.
112419
14.4
High voltage components
No high-voltage components.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
P
Protective devices used within their ratings
Thermal links and fuse
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified protective devices
applied.
See list of critical components.
applied.
See list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-outs
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
Thermal links in main and
sub transformer, separately
approved. See appended
table list of critical components
sub transformer, separately
approved. See appended
table list of critical components
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No such thermal device
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC 60127
Fuse is approved
according to IEC 60127,
see list of critical components.
according to IEC 60127,
see list of critical components.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder .... :
Marked on PCB adjacent to
fuse as;
F901: T 4A L 250V
fuse as;
F901: T 4A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ................ :
No possible to connect fuse
in parallel.
in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No PTC’s thermistors.
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
No such components
N/A
- Page 19 of 39 -
Report
No.
112419
14.6 Switches
P
14.6.1 a) Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3 and
Normal pollution suitability
Resistance to heat and fire level 3 and
Make and break speed independent of speed of
actuation
actuation
V-0 compliance with annex G, G.1.1
Mains switch and relay provided.
Certified according to
IEC 61058-1.
- Mains switch, certified by VDE
- Mains relay, certified by
SEMKO.
See appended table, list of
critical components.
Certified according to
IEC 61058-1.
- Mains switch, certified by VDE
- Mains relay, certified by
SEMKO.
See appended table, list of
critical components.
P
14.6.1 b) Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and
V-0 in annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and
V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage <
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-1
subclause 13.1 and has making/breaking action
independent of speed of actuation
subclause 13.1 and has making/breaking action
independent of speed of actuation
Separately approved switch
and relay.
and relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-1
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
Separately approved switch
and relay.
and relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved switch
and relay.
and relay.
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
The apparatus is not provided
the socket outlet, but measured
the apparatus surge through,
- Mains switch: 17 A peak
- Mains relay: < 1 A peak
The measured inrush current
value is less than rated inrush
current rating of the mains
switch and relay. OK.
the socket outlet, but measured
the apparatus surge through,
- Mains switch: 17 A peak
- Mains relay: < 1 A peak
The measured inrush current
value is less than rated inrush
current rating of the mains
switch and relay. OK.
P
- Page 20 of 39 -
Report
No.
112419
Socket outlet current marking correct
No mains socket-outlets
N/A
14.7 Safety
interlocks
No safety interlocks.
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
and the like
No voltage setting devices.
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
No motors
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
No such construction.
N/A
14.10 Batteries
No batteries.
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
No optocouplers
N/A
Optocouplers comply with Cl. 8
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N/A
14.12
Surge suppression varistors
No surge suppression
varistors
varistors
N/A