Harman Kardon AVR 138 EMC - CB Certificate ▷ View online
- Page 33 of 39 -
Report
No.
112419
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ......... :
207V or 253V
—
Ambient temperature (
o
C) ................................... :
23 - 26
°C
—
Monitored point:
Under fault conditions specified below
dT (K)
Limit dT
(K)
1. *), D112 (A-C), SC, 30 min;
Normal operated, FI stabilised at 1.10A, R115 opened,
Normal operated, FI stabilised at 1.10A, R115 opened,
No hazard.
N/A N/A
2. *), C124, SC, 10 min;
Normal operated, FI stabilised at 1.12A, R115 and R114 opened,
Normal operated, FI stabilised at 1.12A, R115 and R114 opened,
No hazard.
N/A N/A
3. *), D114 (A-C), SC, 30 min;
Normal operated, FI stabilised at 1.13A, R104 opened,
Normal operated, FI stabilised at 1.13A, R104 opened,
No hazard.
N/A N/A
4. *), D117 (A-C), SC, 30 min;
Normal operated, FI stabilised at 1.12A, R105 opened,
Normal operated, FI stabilised at 1.12A, R105 opened,
No hazard.
N/A N/A
5. *), D104 (A-C), SC, 30 min;
Normal operated, FI stabilised at 1.12A, R106 opened,
Normal operated, FI stabilised at 1.12A, R106 opened,
No hazard.
N/A N/A
6. *), C914, SC, 10 min;
Normal operated, FI stabilised at 1.12A, R106 and R107 opened,
Normal operated, FI stabilised at 1.12A, R106 and R107 opened,
No hazard.
N/A N/A
7. *), C930, SC, 10 min;
Unit shut down after 1 sec, FI stabilised at 0.01A, R104 and R105 opened,
Unit shut down after 1 sec, FI stabilised at 0.01A, R104 and R105 opened,
No hazard.
N/A N/A
8. *), D118 (A-C), SC, 20 min;
Output signal off immediately, FI stabilised at 0.42A, R116 and R117 opened,
Output signal off immediately, FI stabilised at 0.42A, R116 and R117 opened,
No hazard.
N/A N/A
9. *), C128, SC, 30 min;
Output signal dropped to 3.3V immediately, FI stabilised at 0.68A,
R116 and R117 opened,
Output signal dropped to 3.3V immediately, FI stabilised at 0.68A,
R116 and R117 opened,
No hazard.
N/A N/A
10. *), D121 (A-C), SC, 10 min;
Normal operated, FI stabilised at 1.12A, R117 opened,
Normal operated, FI stabilised at 1.12A, R117 opened,
No hazard.
N/A N/A
11. *), C129, SC, 10 min;
Output signal off immediately, FI stabilised at 0.41A, R116 and R117 opened,
Output signal off immediately, FI stabilised at 0.41A, R116 and R117 opened,
No hazard.
N/A N/A
12. *), D122 (A-C), SC, 10 min;
Normal operated, FI stabilised at 1.12A, R118 opened,
Normal operated, FI stabilised at 1.12A, R118 opened,
No hazard.
N/A N/A
13. *), C130, SC, 10 min;
Normal operated, FI stabilised at 1.12A, R118 and R119 opened,
Normal operated, FI stabilised at 1.12A, R118 and R119 opened,
No hazard.
N/A N/A
*) Tested at 253V
**) Tested at 207V
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
- Page 34 of 39 -
Report
No.
112419
Monitored point:
Under fault conditions specified below
- continued
dT (K)
Limit dT
(K)
14. *), D108 (A-C), SC, 20 min;
Normal operated, FI stabilised at 1.12A, R101 opened,
Normal operated, FI stabilised at 1.12A, R101 opened,
No hazard.
N/A N/A
15. *), C122, SC, 30 min;
Normal operated, FI stabilised at 1.11A, R101 opened,
Normal operated, FI stabilised at 1.11A, R101 opened,
No hazard.
N/A N/A
16. *), C117, SC, 20 min;
Normal operated, FI stabilised at 1.13A, NCD,
Normal operated, FI stabilised at 1.13A, NCD,
No hazard.
N/A N/A
17. **), D991 (AC-+), SC, 10 min;
Unit shut down immediately, FI stabilised at 0.01A, NCD,
Unit shut down immediately, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
18. *), D991 (AC-+), SC, 10 min;
Unit shut down immediately, FI stabilised at 0.01A, NCD,
Unit shut down immediately, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
19. **), D992 (AC-+), SC, 10 min;
Unit shut down immediately, FI stabilised at 0.01A, NCD,
Unit shut down immediately, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
20. *), D992 (AC-+), SC, 10 min;
Unit shut down immediately, FI stabilised at 0.01A, NCD,
Unit shut down immediately, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
21. *), D962 (A-C), SC, 9 min;
Sub transformer primary winding heated-up to 99K and
thermal fuse opened after 9 min, Dielectric strength test O.K., No hazard.
Sub transformer primary winding heated-up to 99K and
thermal fuse opened after 9 min, Dielectric strength test O.K., No hazard.
Sub transf.
99
Sub transf.
150
22. *), D901 (A-C), SC, 8 min;
Sub transformer primary winding heated-up to 98K and
thermal fuse opened after 8 min, Dielectric strength test O.K., No hazard.
Sub transformer primary winding heated-up to 98K and
thermal fuse opened after 8 min, Dielectric strength test O.K., No hazard.
Sub transf.
98
Sub transf.
150
23. *), C906, SC, 10 min;
Sub transformer primary winding heated-up to 102K and
thermal fuse opened after 10 min, Dielectric strength test O.K., No hazard.
Sub transformer primary winding heated-up to 102K and
thermal fuse opened after 10 min, Dielectric strength test O.K., No hazard.
Sub transf.
102
Sub transf.
150
24. **), C902, SC, 10 min;
Unit shut down immediately, FI stabilised at 0.01A, NCD,
Unit shut down immediately, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
25. *), C902, SC, 10 min;
Unit shut down immediately, FI stabilised at 0.01A, NCD,
Unit shut down immediately, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
26. **), C915, SC, 10 min;
Unit shut down immediately, FI stabilised at 0.01A, NCD,
Unit shut down immediately, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
27. *), C915, SC, 10 min;
Unit shut down immediately, FI stabilised at 0.01A, NCD,
Unit shut down immediately, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
28. *), Q657 (C-E), SC, 10 min;
Unit shut down after 3 sec, FI stabilised at 0.01A, Q661 damaged,
Unit shut down after 3 sec, FI stabilised at 0.01A, Q661 damaged,
No hazard.
N/A N/A
*) Tested at 253V
**) Tested at 207V
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
- Page 35 of 39 -
Report
No.
112419
Monitored point:
Under fault conditions specified below- continued
dT (K)
Limit dT
(K)
29. *), Q657 (B-C), SC, 10 min;
Unit shut down after 3 sec, FI stabilised at 0.01A, NCD,
Unit shut down after 3 sec, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
30. *), Q661 (C-E), SC, 10 min;
Unit shut down after 4 sec, FI stabilised at 0.01A, Q657 damaged,
Unit shut down after 4 sec, FI stabilised at 0.01A, Q657 damaged,
No hazard.
N/A N/A
31. *), Q661 (B-C), SC, 10 min;
Unit shut down after 3 sec, FI stabilised at 0.01A, NCD,
Unit shut down after 3 sec, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
32. *), C631, SC, 30 min;
Center output off immediately, FI stabilised at 1.02A, R631 opened,
Center output off immediately, FI stabilised at 1.02A, R631 opened,
No hazard.
N/A N/A
33. *), Speaker output terminal (Front L-ch.), SC, 10 min;
Unit shut down immediately, FI stabilised at 0.01A, NCD,
Unit shut down immediately, FI stabilised at 0.01A, NCD,
No hazard.
N/A N/A
34. *), Ventilation opening (Blocked), 13 min;
Unit shut down after 13 min, FI stabilised at 0.01A, Dielectric strength test O.K.,
No hazard.
Unit shut down after 13 min, FI stabilised at 0.01A, Dielectric strength test O.K.,
No hazard.
N/A N/A
35. *), Pmax. Operating (Maximum non-clipped output signal);
Winding of main transformer heated up to 137K and thermal fuse opened
after 9 min, FI stabilised at 0.01A, Dielectric strength test O.K., No hazard.
Winding of main transformer heated up to 137K and thermal fuse opened
after 9 min, FI stabilised at 0.01A, Dielectric strength test O.K., No hazard.
Main transf.
137
Main transf.
150
*) Tested at 253V
**) Tested at 207V
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
- Page 36 of 39 -
Report
No.
112419
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference **)
Mains plug/cord
(For CENELEC)
alt.
alt.
(For CENELEC)
alt.
alt.
KENIC ELECTRIC.
KENIC ELECTRIC.
KENIC ELECTRIC.
VOLEX (ASIA) PTE.
KE-21
H03VVH2-F
KE-32
H03VVH2-F
M4206
H03VVH2-F
H03VVH2-F
KE-32
H03VVH2-F
M4206
H03VVH2-F
2.5A/250V
6A/250V
2.5A/250V
6A/250V
2.5A/250V
6A/250V
6A/250V
2.5A/250V
6A/250V
2.5A/250V
6A/250V
IEC60884-1
IEC60884-1
IEC60884-1
IEC60884-1
IEC60884-1
VDE
VDE
VDE
VDE
VDE
Mains plug/cord
(For UK and
Singapore)
(For UK and
Singapore)
KENIC ELECTRIC. KE-108
H03VVH2-F, or
H05VVH2-F
H05VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
SS145
SS145
BSI, PSB
Mains plug/cord
(For UK)
alt.
alt.
alt.
alt.
(For UK)
alt.
alt.
alt.
alt.
VOLEX (ASIA) PTE
VOLEX (ASIA) PTE
WINBO
INDUSTRIES
LUEN TAI (IP’S)
KENIC ELECT.
WELL SHIN
ENTERPRISE.
VOLEX (ASIA) PTE
WINBO
INDUSTRIES
LUEN TAI (IP’S)
KENIC ELECT.
WELL SHIN
ENTERPRISE.
MP5004A
H03VVH2-F
MP5005
H03VVH2-F
MS 323N
H03VVH2-F
9518
H03VVH2-F
WS-012A
H03VVH2-F
H03VVH2-F
MP5005
H03VVH2-F
MS 323N
H03VVH2-F
9518
H03VVH2-F
WS-012A
H03VVH2-F
13A/250V
6A/250V
13A/250V
6A/250V
13A/250V
6A/250V
13A/250V
6A/250V
13A/250V
6A/250V
6A/250V
13A/250V
6A/250V
13A/250V
6A/250V
13A/250V
6A/250V
13A/250V
6A/250V
BS1363
BS6500
BS1363
BS6500
BS1363
BS6500
BS1363
BS6500
BS1363
BS6500
BS6500
BS1363
BS6500
BS1363
BS6500
BS1363
BS6500
BS1363
BS6500
BSI
BSI
BSI
BSI
BSI
BSI
BSI
BSI
BSI
Mains switch
(SW1)
(SW1)
POSTEC Electric.
SDL1P-B
5A/80A 250V
IEC60065
IEC61058-1
IEC61058-1
VDE
Mains relay
(RY94)
(RY94)
Tyco Electronics
SDT-S-112DMR
8A/120A 250V
IEC60065
IEC 61058-1
IEC 61058-1
SEMKO
Main transf.
Bobbin Material
Thermal fuse
Bobbin Material
Thermal fuse
Seoul Electronics
& Telecom Co Ltd.
Wintech Polymer
Therm-O-Disc.
& Telecom Co Ltd.
Wintech Polymer
Therm-O-Disc.
KLT5U026ZE
CLT5U026ZE
CN9030
E4A51167C
CLT5U026ZE
CN9030
E4A51167C
230V, Class B
PET, V-0, 155°C
10A/250V, 167 °C
PET, V-0, 155°C
10A/250V, 167 °C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL, E2131445
VDE
UL, E2131445
VDE
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition