Report
No.
112419
17.8
Fixing devices for detachable legs or stands provided
No detachable provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Connections complies,
checked by inspection
checked by inspection
P
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
No picture tube used.
N/A
Picture tube separately approved to 18.1 ...............
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N/A
Protective film as part of implosion protection: edges
covered by enclosure
covered by enclosure
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
- Page 26 of 39 -
Report
No.
112419
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg .................. :
Apparatus weight: 9.4kg
—
Apparatus intended to be fastened in place – suitable
instructions
instructions
No
P
19.1
Test on a plane, inclined at 10
o
to the horizontal
Tested on a plane inclined at
an angle of 10°
an angle of 10°
P
19.2
100 N force applied vertically downwards
100N force has no influence
on the stability.
on the stability.
P
19.3
100 N force, or 13% of weight, applied horizontally to
point of least stability.
point of least stability.
< 25 kg and < 1 M
N/A
19.4
Edges or corners not hazardous
There is no hazardous edges
or corners when the apparatus
is operating in normal position
or corners when the apparatus
is operating in normal position
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1
No glass surface
N/A
19.6
Wall or ceiling mountings adequate
Not intended for wall or ceiling
mounting
mounting
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC
enclosure of material V-0 to IEC
60695-11-10
with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in 20.1
PCB is of flammability class
V-1 or better, and exception is
made for small components.
V-1 or better, and exception is
made for small components.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components comply
with flammability requirements
in clause 14.
with flammability requirements
in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages > 4 Kv or
leaving an internal fire enclosure,
leaving an internal fire enclosure,
or located within the
areas mentioned in Table 21,
not contributing to the
spread of fire
No wires working at voltage
> 4kV. or leaving an internal
fire enclosure
> 4kV. or leaving an internal
fire enclosure
N/A
- Page 27 of 39 -
Report
No.
112419
20.1.3
Material of printed circuit boards on which the available
power exceeds 15 W at a voltage between 50 V and
400 V (peak) a.c. or d.c. meets V-1 or better to
IEC60707, unless used in a fire enclosure
power exceeds 15 W at a voltage between 50 V and
400 V (peak) a.c. or d.c. meets V-1 or better to
IEC60707, unless used in a fire enclosure
All PCB are of base material
with flammability category
V-1 or better. See list of
critical components.
with flammability category
V-1 or better. See list of
critical components.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
< 400V (peak) or d.c.
N/A
20.1.4
Components and parts not covered by 20.1.1, 20.1.2
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the distances
in Table 21 comply with the relevant flammability
category in Table 21
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the distances
in Table 21 comply with the relevant flammability
category in Table 21
No such components
N/A
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N/A
Apparatus with voltages >4kV under normal operating
conditions and distances to the enclosure exceed
those specified Table 21, flammability classification
HB40 or better is required for the enclosure.
conditions and distances to the enclosure exceed
those specified Table 21, flammability classification
HB40 or better is required for the enclosure.
Normal operating voltage
< 4KV
N/A
20.2 Fire
enclosure
No fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage > 4 kV
(peak) a.c. or d.c. contained in a fire enclosure to V-1
(peak) a.c. or d.c. contained in a fire enclosure to V-1
No voltages exceeding 4kV,
no fire enclosure requirement
no fire enclosure requirement
N/A
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires completely
filled
1 mm in width and with openings for wires completely
filled
No internal fire enclosure
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an internal
fire enclosure
fire enclosure
No internal fire enclosure
N/A
- Page 28 of 39 -
Report
No.
112419
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
Not intended for outdoor use
N/A
A.10.2.1 Enclosure provides protection against splashing water
N/A
A.10.2.2 Humidity
treatment carried out for 7 days
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex B
of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex B
of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this standard
modified in accordance with annex B of this standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A