Date

Harman Kardon AVR 138 EMC - CB Certificate ▷ View online

 
 
- Page 25 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
17.8 
Fixing devices for detachable legs or stands provided
No detachable provided 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
Connections complies, 
checked by inspection 
 
 
 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
 
Picture tube separately approved to IEC 61965: 
No picture tube used. 
N/A 
 
Picture tube separately approved to 18.1  ...............  
 
N/A 
18.1 
Picture tubes > 16 cm intrinsically protected 
 
N/A 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
 
N/A 
 
Protective film as part of implosion protection: edges 
covered by enclosure 
 
N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
N/A 
18.2.1 
Samples subject to ageing: 6 
 
N/A 
18.2.2 
Samples subject to implosion test: 6 
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 
N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
N/A 
 
 
- Page 26 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
 
Mass of the equipment exceeding 7 kg  .................. : 
Apparatus weight: 9.4kg 
— 
 
Apparatus intended to be fastened in place – suitable 
instructions 
No  
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
Tested on a plane inclined at  
an angle of 10° 
19.2 
100 N force applied vertically downwards 
100N force has no influence  
on the stability. 
19.3 
100 N force, or 13% of weight, applied horizontally to 
point of least stability. 
< 25 kg and < 1 M 
N/A 
19.4 
Edges or corners not hazardous 
There is no hazardous edges  
or corners when the apparatus 
is operating in normal position 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension > 450 mm, 
pass the test of 19.5.1 
No glass surface 
N/A 
19.6 
Wall or ceiling mountings adequate 
Not intended for wall or ceiling 
mounting 
N/A 
 
 
 
 
20 
RESISTANCE TO FIRE 
 
20.1 
Electrical components and mechanical parts 
P
 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 
60695-11-10
 with 
openings not exceeding 1 mm in width 
 
N/A 
 
b) Exemption for small components as defined in 20.1
PCB is of flammability class 
V-1 or better, and exception is 
made for small components.
 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 
Electrical components comply  
with flammability requirements  
in clause 14. 
20.1.2 
Insulation of internal wiring working at voltages > 4 Kv or 
leaving an internal fire enclosure,
 or located within the 
areas mentioned in Table 21,
 not contributing to the 
spread of fire 
No wires working at voltage 
> 4kV. or leaving an internal  
fire enclosure 
N/A 
 
 
- Page 27 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
20.1.3 
Material of printed circuit boards on which the available 
power exceeds 15 W at a voltage between 50 V and 
400 V (peak) a.c. or d.c. meets V-1 or better to 
IEC60707, unless used in a fire enclosure 
All PCB are of base material  
with flammability category 
V-1 or better.  See list of  
critical components. 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
< 400V (peak) or d.c. 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 20.1.2 
and 20.1.3 (other than fire enclosures) mounted 
nearer to a potential ignition source than the distances 
in Table 21 comply with the relevant flammability 
category in Table 21 
No such components 
N/A 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
No such components 
N/A 
 
Apparatus with voltages >4kV under normal operating 
conditions and distances to the enclosure exceed 
those specified Table 21, flammability classification 
HB40 or better is required for the enclosure. 
Normal operating voltage 
< 4KV
 
N/A 
20.2 Fire 
enclosure 
No fire enclosure
 
N/A
 
20.2.1 
Potential ignition sources with open circuit voltage > 4 kV 
(peak) a.c. or d.c. contained in a fire enclosure to V-1 
No voltages exceeding 4kV,  
no fire enclosure requirement
 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires completely 
filled 
No internal fire enclosure 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an internal 
fire enclosure 
No internal fire enclosure 
N/A 
 
 
- Page 28 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
Not intended for outdoor use 
N/A 
A.10.2.1  Enclosure provides protection against splashing water
 
N/A 
A.10.2.2 Humidity 
treatment carried out for 7 days 
 
N/A 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1 
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex B 
of this standard 
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this standard 
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 