Harman Kardon AVR 138 EMC - CB Certificate ▷ View online
- Page 37 of 39 -
Report
No.
112419
14
TABLE: list of critical components and materials-continued
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference **)
Sub transf.
Bobbin Material
alt.
alt.
Thermal fuse
Bobbin Material
alt.
alt.
Thermal fuse
Seoul Electronics
& Telecom Co Ltd.
EI DUPONT.
Wintech Polymer
Samyang Co Ltd.
Anzen Dangu Co.
& Telecom Co Ltd.
EI DUPONT.
Wintech Polymer
Samyang Co Ltd.
Anzen Dangu Co.
KLT5J033YE /
CLT5J033YE
FR530
CN9030
2550GN30
K11
CLT5J033YE
FR530
CN9030
2550GN30
K11
230V, Class E
PET, V-0, 155°C
PET, V-0, 155°C
PET, V-0, 140°C
1A/250V, 115 °C
PET, V-0, 155°C
PET, V-0, 155°C
PET, V-0, 140°C
1A/250V, 115 °C
IEC60065
clause 14.3
UL94
UL94
UL94
IEC60691
clause 14.3
UL94
UL94
UL94
IEC60691
1.)
UL,
UL,
E69578
UL,
E2131445
UL,
E121254
VDE
Mains fuse
(F901)
alt.
alt.
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Electronic.
SUN Electronics
Walter Electronic.
50T
218
218
004
5T
TSD
TSD
T4A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Relay across
the cap (C904)
alt.
alt.
alt.
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
IEC
60384-14,
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
Enclosure Mtl.
Body, top cover
Front panel
alt.
Display window
alt.
Front panel
alt.
Display window
alt.
Various
Kumho Chemical
Various
Mitsubishi Rayon
Various
Various
HFA-452
Various
L530
Various
Sheet Steel,
Min. 0.8mm
V-2,
Min. 2.0mm
Min. V-2, 2.0mm
HB,
Min. 2.0mm
Min. HB, 2.0mm
-
UL94
UL94
UL94
UL94
1.)
UL, E65424
UL
UL, E54695
UL
PCB
Various
Various
Min. V-1, 130°C
UL 796
UL
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition
- Page 38 of 39 -
Report
No.
112419
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Class II apparatus
N/A
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Class II apparatus
N/A
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
P
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
Class II apparatus
N/A
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
P
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
Class II apparatus.
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
BSI approved plug and cord
provided
provided
P
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
When marketing in Ireland,
the apparatus must be
supplied with a cord and plug
acceptable in Ireland.
the apparatus must be
supplied with a cord and plug
acceptable in Ireland.
N/A
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
P
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
Comply
P
- Page 39 of 39 -
Report
No.
112419
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
Comply
P
- protecting rim also tested
Class II apparatus
N/A
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
No TNV circuits
N/A
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Class II apparatus.
N/A
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
5
DE: additional markings required in German language:
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No CRT in the equipment
N/A
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N/A
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: certification number on the back cover
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No switches containing
mercury
mercury
N/A
- IEC 60065 7
th
edition (2001)
- Page 1 of 1 -
www.nemko.com
Report No.
112419
APPENDIX: SINGAPORE DEVIATIONS
to IEC 60065 7
th
ed. (2001)
(CB Bulletin No. 105A, May 2003)
Clause
Requirement – Test
Result - Remark
Ver-
dict
4
All apparatus must be tested to 230 Vac
230 Vac tested
P
4.3.13
Apparatus fitted with voltage selector switch must
be tested as follows:
be tested as follows:
Connect apparatus to 230 V ac mains with voltage
selector switch to settings not suitable for operation
at 230 V ac.
selector switch to settings not suitable for operation
at 230 V ac.
No voltage selector.
N/A
5.3
Circuit diagrams must be indicated with component
values.
values.
P
Circuit diagrams of electronic modules in the
apparatus must be provided.
apparatus must be provided.
P
7.1, 11.2
Permissible temperature rises of 10K less than
those specified in Table 2 are required.
those specified in Table 2 are required.
Meets tropical limits
P
10.2
Humidity treatment. Adopt the testing conditions
designed for tropical conditions.
designed for tropical conditions.
5 days
P
15.1.1
All Class I apparatus must be fitted with 3-pin mains
plugs that comply with SS 145/SS 472 that are
registered with the Safety Authority
plugs that comply with SS 145/SS 472 that are
registered with the Safety Authority
Class II apparatus
N/A
a) All Class II apparatus must be fitted with 2-pin
mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075.
mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075.
N/A
b) Class II apparatus that are fitted with 3-pin mains
plugs must use plugs that comply with SS 145 and
registered with the Safety Authority.
plugs must use plugs that comply with SS 145 and
registered with the Safety Authority.
PSB approved plug provided
P
15.3
Apparatus
≥ 3 kW must be connected to fixed
wiring. All connection to fixed wiring must be in
accordance with Code of Practice CP5.
accordance with Code of Practice CP5.
< 3 kW
N/A
16
Detachable power cord set must be listed in the test
report critical component list.
report critical component list.
Not detachable
N/A
Misc.
Apparatus enclosure which is shaped and
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration.
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration.
Not shaped like toy.
P
Click on the first or last page to see other AVR 138 service manuals if exist.