Harman Kardon AVR 138 EMC - CB Certificate ▷ View online
- Page 29 of 39 -
Report
No.
112419
IEC 62151 clause 4.1.1:
Add after the first paragraph:
Add after the first paragraph:
NOTE-
In Finland, Norway and Sweden, class I equipment
which is intended for connection to the building
installation via a non-industrial plug or a non-industrial
appliance coupler or both and in addition is intended
for connection to other equipment or a network shall,
if safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts, have
a marking stating that the equipment must be
connected to an earthed mains socket-outlet.
In Finland, Norway and Sweden, class I equipment
which is intended for connection to the building
installation via a non-industrial plug or a non-industrial
appliance coupler or both and in addition is intended
for connection to other equipment or a network shall,
if safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts, have
a marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follow:
be as follow:
In Finland;
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
In Norway; ”Apparatet mǻ tikoples jordet stikkontakt”
In Sweden; ”Apparaten skall anslutas till jordat uttag”
Class II apparatus
N/A
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
L5.4
Marking and Instructions
N/A
L9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in Table
3 , unless comply with 6.3.2 of IEC 60086-4
3 , unless comply with 6.3.2 of IEC 60086-4
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
- Page 30 of 39 -
Report
No.
112419
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
In OFF/Stand-by position,
the power consumption is
less than 2.2W.
the power consumption is
less than 2.2W.
P
Position of the functional switch (W) ...................... : -
—
Operating conditions
Standby mode:
207
0.008 1.3 —
230 0.010 1.6 —
253 0.014 2.2 —
Measured at maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
253
2.45
545
2 x 49.0 W
(F)
1 x 46.6 W
(C)
2 x 46.1 W
(S)
Measured at 1/8 of maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
207 1.13
#) 1.05
189
#) 176
2 x 6.13 W
(F)
1 x 5.83 W
(C)
2 x 5.76 W
(S)
230 1.15
#) 1.09
212
#) 200
2 x 6.13 W
(F)
1 x 5.83 W
(C)
2 x 5.76 W
(S)
253 1.16
#) 1.12
237
#) 227
2 x 6.13 W
(F)
1 x 5.83 W
(C)
2 x 5.76 W
(S)
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads connected conditions for
F, C and S channels, and than replaced the input signal to pink noise for heating and fault condition tests
F, C and S channels, and than replaced the input signal to pink noise for heating and fault condition tests
The values followed #) in table above are measured “A” or “W” value, when replaced the input signal from
1 kHz sign wave to pink noise.
1 kHz sign wave to pink noise.
Loudspeaker impedance (Ω). 8 Ohm
—
Several loudspeaker systems
Right and Left for Front,
Only one for Center,
Right and Left for Surround
Only one for Center,
Right and Left for Surround
P
Marking of loudspeaker
terminals
terminals
SPEAKERS ( 8
Ω):
FRONT, CENTER, SURROUND
P
- Page 31 of 39 -
Report
No.
112419
Winding temperature rise Measurements
207V 253V
—
Ambient temperature t1 (°C)
23.6 23.6
—
Ambient temperature t1 (°C)
22.3 22.3
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT(K)
Limit dT
(K) *)
Insulation
class
Main transf. pr. winding (207V)
5.66
7.15 69.2 95
B
Sub transf. pr. winding (207V)
2845
3230 36.2 85
E
Main transf. pr. winding (253V)
5.66
7.40 80.6 95
B
Sub transf. pr. winding (253V)
2845
3424 53.8 85
E
*) Temperature rise limits for Singapore is 10K less
Test Condition: Pink noise input signal and 8 ohm loads connected conditions for F, C and S channels.
Monitored point:
dT (K) at
207V
dT (K) at
253V
Limit dT (K)
*)
Main transformer case
44.4
53.4
95
Sub transformer core
31.0
42.0
85
PWB near D991
50.4
55.4
85
PWB near D992
42.3
46.6
85
Diode, D991 body
52.3
57.7
-
Diode, D992 body
40.5
44.9
-
Resistor, R659 body
26.8
30.2
-
Main heat-sink
40.7
53.0
-
TR, Q804 body
44.4
57.4
-
PWB near Q804
34.9
45.6
85
E. Capacitor, C909 body
22.5
25.7
85
°C
Power cord bushing
11.6
13.1
60
Top enclosure above main transf.
20.4
24.7
40
Top enclosure above main heat-sink
22.9
30.0
40
Power switch button
1.1
1.7
50
- Page 32 of 39 -
Report
No.
112419
7.2
TABLE: softening temperature of thermoplastics
N/A
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
2
Between parts separated by double or reinforced insulation
> 100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Between mains poles (primary fuse disconnected)
1500Vac
No
Between parts separated by double or reinforced insulation
3000Vac
No