Harman Kardon ABH-4 (serv.man10) EMC - CB Certificate ▷ View online
page 24 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
4.7
Resistance to fire
Pass
4.7.1
Reducing the risk of ignition and spread of flame
Method 1: Selection and
application of components
and materials which minimize
the possibility of ignition and
spread of flame.
application of components
and materials which minimize
the possibility of ignition and
spread of flame.
Pass
4.7.2
Conditions for a fire enclosure
With having the following
components:
components:
-
Components with winding
-
Wiring
-
Semiconductor devices,
transistor, diodes,
integrated circuits
transistor, diodes,
integrated circuits
-
Resistors, capacitors,
inductor
inductor
The fire enclosure is required.
Pass
4.7.2.1
Parts requiring a fire enclosure
A fire enclosure covers all
parts.
parts.
Pass
4.7.2.2
Parts not requiring a fire enclosure
Fire enclosure covers all
parts.
parts.
Pass
4.7.3
Materials
Pass
4.7.3.1
General
See below.
Pass
4.7.3.2
Materials for fire enclosures
The fire enclosure is plastic
rated V-0.
rated V-0.
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Fire enclosure covers all
parts.
parts.
N/A
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
All internal materials are rated
V-2 or better or are mounted
on a PWB rated V-1 or better.
V-2 or better or are mounted
on a PWB rated V-1 or better.
Internal wiring is UL
Recognized, marked VW-1 or
FT-1 and strapped by
individual cable ties (where
needed).
Recognized, marked VW-1 or
FT-1 and strapped by
individual cable ties (where
needed).
See Table 1.5 for material
information.
information.
Pass
4.7.3.5
Materials for air filter assemblies
The equipment does not have
any air filters.
any air filters.
N/A
4.7.3.6
Materials used in high-voltage components
No high-voltage components.
N/A
page 25 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
Pass
5.1
Touch current and protective conductor current
Pass
5.1.1
General
See below.
Pass
5.1.2
Equipment under test (EUT)
Equipment designed for
connection to only one power
source.
connection to only one power
source.
Pass
5.1.3
Test circuit
Single phase equipment
intended for connection to TN
system.
intended for connection to TN
system.
Pass
5.1.4
Application of measuring instrument
Test made to 10X20 cm metal
foil in contact with accessible
non-conductive part.
foil in contact with accessible
non-conductive part.
Pass
5.1.5
Test procedure
Considered.
Pass
5.1.6
Test measurements
See appended test record.
Pass
Test voltage (V) ................................................: 264 Vac.
Measured current (mA) ....................................: See enclosed test record.
Max. allowed current (mA) ................................: 3.5 mA. (Class I movable)
5.1.7
Equipment with touch current exceeding
3.5 mA ...........................................................:
3.5 mA ...........................................................:
Touch current is < 3.5 mA.
Pass
5.1.8
Touch currents to and from telecommunication
networks
networks
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network
telecommunication network
N/A
Test voltage (V) ................................................:
Measured current (mA) ....................................:
Max. allowed current (mA) ................................:
5.1.8.2
Summation of touch currents from
telecommunication networks ............................ :
telecommunication networks ............................ :
N/A
5.2
Electric strength
Pass
5.2.1
General
Based on the electric strength
test the use of the insulating
materials within the
equipment is satisfactory.
test the use of the insulating
materials within the
equipment is satisfactory.
(See enclosed test report)
Pass
5.2.2
Test procedure
No insulation breakdown
detected during the test.
detected during the test.
(see enclosed test record)
Pass
page 26 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
5.3
Abnormal operating and fault conditions
Pass
5.3.1
Protection against overload and abnormal
operation
operation
(see enclosed test record)
Pass
5.3.2
Motors
N/A
5.3.3
Transformers
Transformers are constructed
in accord with the applicable
Clause and Annex C.
in accord with the applicable
Clause and Annex C.
Pass
5.3.4
Functional insulation ......................................... : Functional insulation between
the phases before the fuse
complies with method (a),
other operation insulation
complies with method (C).
Short-circuit tests, results see
nclosed test record.
complies with method (a),
other operation insulation
complies with method (C).
Short-circuit tests, results see
nclosed test record.
Pass
5.3.5
Electromechanical components
The equipment does not have
any electromechanical
components in the secondary.
any electromechanical
components in the secondary.
N/A
5.3.6
Simulation of faults
See enclosed test record for
abnormal operation tests.
abnormal operation tests.
Pass
5.3.7
Unattended equipment
The equipment does not have
any thermostats, temperature
limiters, or thermal cut-outs.
any thermostats, temperature
limiters, or thermal cut-outs.
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
fault conditions
No fire, emission of molten
metal or deformation was
noted during the tests.
metal or deformation was
noted during the tests.
Electric strength tests
performed after abnormal and
fault tests.
performed after abnormal and
fault tests.
Pass
page 27 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service personnel, and users of
other equipment connected to the network, from hazards in the equipment
other equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
Test voltage (V) ................................................:
Current in the test circuit (mA) ........................:
6.1.2.2
Exclusions.........................................................:
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of telecommunication wiring system from overheating
N/A
Max. output current (A)...................................... :
Current limiting method ..................................... :