DOWNLOAD Harman Kardon ABH-4 (serv.man10) Service Manual ↓ Size: 4.31 MB | Pages: 102 in PDF or view online for FREE

Model
ABH-4 (serv.man10)
Pages
102
Size
4.31 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
abh-4-sm10.pdf
Date

Harman Kardon ABH-4 (serv.man10) EMC - CB Certificate ▷ View online

 
page 8 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
PROTECTION FROM HAZARDS 
Pass 
2.1 
Protection from electric shock and energy hazards 
Pass 
2.1.1 
Protection in OPERATOR access areas  
The construction of this plastic 
enclosure prevents the 
accessibility to any parts with 
only basic insulation to ELV or 
hazardous voltage with test 
pin or test finger. 
Pass 
2.1.1.1 
Access to energized parts 
The operator has access to 
bare parts of SELV 
CIRCUITS. 
 
No operator access to 
energized parts. 
Pass 
 
Test by inspection  ............................................ :  Operator cannot contact with 
any parts with only basic 
insulation to ELV or 
hazardous voltage. 
Pass 
 
Test with test finger  .......................................... :  The test finger was unable to 
contact bare hazardous parts, 
basic insulation, or ELV 
circuits. 
Pass 
 
Test with test pin  .............................................. :  The test pin was unable to 
contact bare hazardous parts. 
Pass 
 
Test with test probe .......................................... :  No TNV present. 
N/A 
2.1.1.2 
Battery compartments ....................................... :  No battery components. 
N/A 
2.1.1.3 
Access to ELV wiring 
Internal wiring in an ELV 
circuit is not user accessible. 
N/A 
 
Working voltage (V); distance (mm) through 
insulation 
      
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No internal wiring accessible 
to the user. 
N/A 
2.1.1.5 
Energy hazards  ................................................ :  No hazardous voltage wiring 
in operator accessible area. 
Pass 
2.1.1.6 
Manual controls 
No shafts or knobs, etc. at 
ELV, TNV or hazardous 
voltage. 
N/A 
2.1.1.7 
Discharge of capacitors in the primary circuit 
No risk of electric shock. 
Pass 
 
Time-constant (s); measured voltage (V) ........... :  See enclosed test record. 
 
2.1.2 
Protection in service access areas 
No bare parts operating at 
HAZARDOUS VOLTAGES in 
a service access area. 
N/A 
2.1.3 
Protection in restricted access locations 
The unit is not intended to be 
used in restricted locations. 
N/A 
 
 
 
 
 
page 9 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
2.2 
SELV circuits 
Pass 
2.2.1 
General requirements 
SELV levels are maintained 
after single fault condition. 
Pass 
2.2.2 
Voltages under normal conditions (V) ................ :  All accessible voltages are 
less than 42.4 Vp or 60 V dc 
and are classified as SELV. 
Pass 
2.2.3 
Voltages under fault conditions (V) .................... :  Under fault conditions 
voltages never exceed 71V 
peak and 120Vdc and do not 
exceed 42.4V peak or 60V dc 
for more than 0.2 sec. 
Pass 
2.2.3.1 
Separation by double or reinforced insulation 
(method 1) 
Hazardous voltage wiring 
which may contact SELV 
parts provided with double or 
reinforced insulation.  See 
2.10.5. 
Pass 
2.2.3.2 
Separation by earthed screen (method 2) 
Method 1 used. 
N/A 
2.2.3.3 
Protection by earthing of the SELV circuit (method 
3) 
Method 1 used. 
N/A 
2.2.4 
Connection of SELV circuits to other circuits....... :  SELV circuit and all 
interconnected circuits 
separated from primary by 
Reinforced/Double insulation.   
The SELV circuit does not 
exceed the SELV limits under 
normal and fault conditions. 
SELV circuits are only 
connected to other secondary 
circuits. 
Pass 
 
page 10 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
2.3 
TNV circuits 
N/A 
2.3.1 
Limits 
-- 
N/A 
 
Type of TNV circuits.......................................... :  -- 
 
2.3.2 
Separation from other circuits and from 
accessible parts 
-- 
N/A 
 
Insulation employed .......................................... :  -- 
 
2.3.3 
Separation from hazardous voltages 
-- 
N/A 
 
Insulation employed .......................................... :  -- 
 
2.3.4 
Connection of TNV circuits to other circuits 
-- 
N/A 
 
Insulation employed .......................................... :  -- 
 
2.3.5 
Test for operating voltages generated externally 
-- 
N/A 
 
 
2.4 
Limited current circuits 
Pass 
2.4.1 
General requirements 
LCC in compliance with the 
limits below under normal and 
single condition.
 
Pass 
2.4.2 
Limit values 
37.8 mA 
Pass 
 
Frequency (Hz) ................................................. :  54 K 
Pass 
 
Measured current (mA) ..................................... :  0.19 
Pass 
 
Measured voltage (V)........................................ :  0.38 
Pass 
 
Measured capacitance (
µ
F)............................... :  3300 pF 
Pass 
2.4.3 
Connection of limited current circuits to other 
circuits 
Complies 
Pass 
 
 
2.5 
Limited power sources 
N/A 
 
Inherently limited output 
-- 
N/A 
 
Impedance limited output 
-- 
N/A 
 
Overcurrent protective device limited output 
-- 
N/A 
 
Regulating network limited output under normal 
operating and single fault condition 
-- 
N/A 
 
Regulating network limited output under normal 
operating conditions and overcurrent protective 
device limited output under single fault condition 
-- 
N/A 
 
Output voltage (V), output current (A), apparent 
power (VA).......................................................: 
-- 
 
 
Current rating of overcurrent protective device (A)  -- 
 
 
page 11 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
2.6 
Provisions for earthing and bonding 
Pass 
2.6.1 
Protective earthing 
See below 
Pass 
2.6.2 
Functional earthing 
Secondary functional earthing 
is connected to protectively 
earthed conductive part which 
part is separated from 
primary by basic insulation. 
Pass 
2.6.3 
Protective earthing and protective bonding 
conductors 
See below. 
Pass 
2.6.3.1 
Size of protective earthing conductors 
Power supply cord suitable for 
application and subject to 
country's national code and 
regulations to be provided by 
the manufacturer. 
Pass 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG: 
      
 
2.6.3.2 
Size of protective bonding conductors 
No power cord provided. 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG: 
      
 
2.6.3.3 
Rated current (A), type and nominal thread 
diameter (mm): 
 
Pass 
 
Resistance (
) of earthing conductors and their 
terminations, test current (A): 
See enclosed test record. 
Pass 
2.6.3.4 
Colour of insulation: 
Evaluated as part of the 
power supply. 
 
Protective earthing conductor 
is green with yellow stripe. 
Pass 
2.6.4 
Terminals 
Appliance inlet used. 
Pass 
2.6.4.1 
Protective earthing and bonding terminals 
The earth pin of the approved 
appliance inlet is considered 
as protective earthing 
terminal.
 
Pass 
 
Rated current (A), type and nominal thread 
diameter (mm) 
The protective bonding
 
conductor is connected to the 
approved appliance.
 
 
2.6.4.2 
Separation of the protective earthing conductor 
from protective bonding conductors 
Appliance inlet used. 
Pass 
2.6.5 
Integrity of protective earthing 
See below. 
Pass 
2.6.5.1 
Interconnection of equipment 
No interconnection of 
hazardous voltage. 
N/A 
2.6.5.2 
Components in protective earthing conductors 
and protective bonding conductors 
No switches or fuses in 
earthing conductors. 
Pass 
2.6.5.3 
Disconnection of protective earth 
It is not possible to disconnect 
protective earth without 
disconnecting mains; an 
appliance inlet is used as 
disconnect device. 
Pass 
Page of 102