Harman Kardon ABH-4 (serv.man10) EMC - CB Certificate ▷ View online
page 8 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
Pass
2.1.1
Protection in OPERATOR access areas
The construction of this plastic
enclosure prevents the
accessibility to any parts with
only basic insulation to ELV or
hazardous voltage with test
pin or test finger.
enclosure prevents the
accessibility to any parts with
only basic insulation to ELV or
hazardous voltage with test
pin or test finger.
Pass
2.1.1.1
Access to energized parts
The operator has access to
bare parts of SELV
CIRCUITS.
bare parts of SELV
CIRCUITS.
No operator access to
energized parts.
energized parts.
Pass
Test by inspection ............................................ : Operator cannot contact with
any parts with only basic
insulation to ELV or
hazardous voltage.
insulation to ELV or
hazardous voltage.
Pass
Test with test finger .......................................... : The test finger was unable to
contact bare hazardous parts,
basic insulation, or ELV
circuits.
basic insulation, or ELV
circuits.
Pass
Test with test pin .............................................. : The test pin was unable to
contact bare hazardous parts.
Pass
Test with test probe .......................................... : No TNV present.
N/A
2.1.1.2
Battery compartments ....................................... : No battery components.
N/A
2.1.1.3
Access to ELV wiring
Internal wiring in an ELV
circuit is not user accessible.
circuit is not user accessible.
N/A
Working voltage (V); distance (mm) through
insulation
insulation
2.1.1.4
Access to hazardous voltage circuit wiring
No internal wiring accessible
to the user.
to the user.
N/A
2.1.1.5
Energy hazards ................................................ : No hazardous voltage wiring
in operator accessible area.
Pass
2.1.1.6
Manual controls
No shafts or knobs, etc. at
ELV, TNV or hazardous
voltage.
ELV, TNV or hazardous
voltage.
N/A
2.1.1.7
Discharge of capacitors in the primary circuit
No risk of electric shock.
Pass
Time-constant (s); measured voltage (V) ........... : See enclosed test record.
2.1.2
Protection in service access areas
No bare parts operating at
HAZARDOUS VOLTAGES in
a service access area.
HAZARDOUS VOLTAGES in
a service access area.
N/A
2.1.3
Protection in restricted access locations
The unit is not intended to be
used in restricted locations.
used in restricted locations.
N/A
page 9 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
2.2
SELV circuits
Pass
2.2.1
General requirements
SELV levels are maintained
after single fault condition.
after single fault condition.
Pass
2.2.2
Voltages under normal conditions (V) ................ : All accessible voltages are
less than 42.4 Vp or 60 V dc
and are classified as SELV.
and are classified as SELV.
Pass
2.2.3
Voltages under fault conditions (V) .................... : Under fault conditions
voltages never exceed 71V
peak and 120Vdc and do not
exceed 42.4V peak or 60V dc
for more than 0.2 sec.
peak and 120Vdc and do not
exceed 42.4V peak or 60V dc
for more than 0.2 sec.
Pass
2.2.3.1
Separation by double or reinforced insulation
(method 1)
(method 1)
Hazardous voltage wiring
which may contact SELV
parts provided with double or
reinforced insulation. See
2.10.5.
which may contact SELV
parts provided with double or
reinforced insulation. See
2.10.5.
Pass
2.2.3.2
Separation by earthed screen (method 2)
Method 1 used.
N/A
2.2.3.3
Protection by earthing of the SELV circuit (method
3)
3)
Method 1 used.
N/A
2.2.4
Connection of SELV circuits to other circuits....... : SELV circuit and all
interconnected circuits
separated from primary by
Reinforced/Double insulation.
separated from primary by
Reinforced/Double insulation.
The SELV circuit does not
exceed the SELV limits under
normal and fault conditions.
exceed the SELV limits under
normal and fault conditions.
SELV circuits are only
connected to other secondary
circuits.
connected to other secondary
circuits.
Pass
page 10 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
2.3
TNV circuits
N/A
2.3.1
Limits
--
N/A
Type of TNV circuits.......................................... : --
2.3.2
Separation from other circuits and from
accessible parts
accessible parts
--
N/A
Insulation employed .......................................... : --
2.3.3
Separation from hazardous voltages
--
N/A
Insulation employed .......................................... : --
2.3.4
Connection of TNV circuits to other circuits
--
N/A
Insulation employed .......................................... : --
2.3.5
Test for operating voltages generated externally
--
N/A
2.4
Limited current circuits
Pass
2.4.1
General requirements
LCC in compliance with the
limits below under normal and
single condition.
limits below under normal and
single condition.
Pass
2.4.2
Limit values
37.8 mA
Pass
Frequency (Hz) ................................................. : 54 K
Pass
Measured current (mA) ..................................... : 0.19
Pass
Measured voltage (V)........................................ : 0.38
Pass
Measured capacitance (
µ
F)............................... : 3300 pF
Pass
2.4.3
Connection of limited current circuits to other
circuits
circuits
Complies
Pass
2.5
Limited power sources
N/A
Inherently limited output
--
N/A
Impedance limited output
--
N/A
Overcurrent protective device limited output
--
N/A
Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
--
N/A
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
operating conditions and overcurrent protective
device limited output under single fault condition
--
N/A
Output voltage (V), output current (A), apparent
power (VA).......................................................:
power (VA).......................................................:
--
Current rating of overcurrent protective device (A) --
page 11 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
2.6
Provisions for earthing and bonding
Pass
2.6.1
Protective earthing
See below
Pass
2.6.2
Functional earthing
Secondary functional earthing
is connected to protectively
earthed conductive part which
part is separated from
primary by basic insulation.
is connected to protectively
earthed conductive part which
part is separated from
primary by basic insulation.
Pass
2.6.3
Protective earthing and protective bonding
conductors
conductors
See below.
Pass
2.6.3.1
Size of protective earthing conductors
Power supply cord suitable for
application and subject to
country's national code and
regulations to be provided by
the manufacturer.
application and subject to
country's national code and
regulations to be provided by
the manufacturer.
Pass
Rated current (A), cross-sectional area (mm
2
),
AWG:
2.6.3.2
Size of protective bonding conductors
No power cord provided.
N/A
Rated current (A), cross-sectional area (mm
2
),
AWG:
2.6.3.3
Rated current (A), type and nominal thread
diameter (mm):
diameter (mm):
Pass
Resistance (
Ω
) of earthing conductors and their
terminations, test current (A):
See enclosed test record.
Pass
2.6.3.4
Colour of insulation:
Evaluated as part of the
power supply.
power supply.
Protective earthing conductor
is green with yellow stripe.
is green with yellow stripe.
Pass
2.6.4
Terminals
Appliance inlet used.
Pass
2.6.4.1
Protective earthing and bonding terminals
The earth pin of the approved
appliance inlet is considered
as protective earthing
terminal.
appliance inlet is considered
as protective earthing
terminal.
Pass
Rated current (A), type and nominal thread
diameter (mm)
diameter (mm)
The protective bonding
conductor is connected to the
approved appliance.
approved appliance.
2.6.4.2
Separation of the protective earthing conductor
from protective bonding conductors
from protective bonding conductors
Appliance inlet used.
Pass
2.6.5
Integrity of protective earthing
See below.
Pass
2.6.5.1
Interconnection of equipment
No interconnection of
hazardous voltage.
hazardous voltage.
N/A
2.6.5.2
Components in protective earthing conductors
and protective bonding conductors
and protective bonding conductors
No switches or fuses in
earthing conductors.
earthing conductors.
Pass
2.6.5.3
Disconnection of protective earth
It is not possible to disconnect
protective earth without
disconnecting mains; an
appliance inlet is used as
disconnect device.
protective earth without
disconnecting mains; an
appliance inlet is used as
disconnect device.
Pass
Click on the first or last page to see other ABH-4 (serv.man10) service manuals if exist.