Harman Kardon ABH-4 (serv.man10) EMC - CB Certificate ▷ View online
page 16 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
2.10.6.5
Electric strength test
2.10.6.6
Abrasion resistance test
N/A
Electric strength test
2.10.7
Enclosed and sealed parts ................................:
N/A
Temperature T
1
=T
2
+ T
mra
– T
amb
+10K (
°
C).......:
N/A
2.10.8
Spacings filled by insulating compound .............:
N/A
Electric strength test
2.10.9
Component external terminations
N/A
2.10.10
Insulation with varying dimensions
N/A
3
WIRING, CONNECTIONS AND SUPPLY
Pass
3.1
General
Pass
3.1.1
Current rating and overcurrent protection
All internal wiring used in the
distribution of primary power
protected against overcurrent
and short circuit by suitably
rated protective devices.
distribution of primary power
protected against overcurrent
and short circuit by suitably
rated protective devices.
Pass
3.1.2
Protection against mechanical damage
The wires are routed away
from sharp edges and parts
which could damage
insulation.
from sharp edges and parts
which could damage
insulation.
Pass
3.1.3
Securing of internal wiring
All wiring is reliably routed or
separated and secured.
separated and secured.
The wires are positioned in
such a manner that prevents
excessive strain, loosening of
terminal connections and
damage of conductor
insulation.
such a manner that prevents
excessive strain, loosening of
terminal connections and
damage of conductor
insulation.
Pass
3.1.4
Insulation of conductors
Insulation on internal
conductors is considered to
be of adequate quality and
suitable for the application
and the working voltage
involved.
conductors is considered to
be of adequate quality and
suitable for the application
and the working voltage
involved.
All internal wirings are UL
Recognized and rated
minimum 300 Vac.
Recognized and rated
minimum 300 Vac.
Pass
3.1.5
Beads and ceramic insulators
The equipment does not have
any beads or similar
insulators.
any beads or similar
insulators.
N/A
3.1.6
Screws for electrical contact pressure
Electrical screw connection is
not used.
not used.
N/A
page 17 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
3.1.7
Non-metallic materials in electrical connections
No contact pressure through
insulating material.
insulating material.
Pass
3.1.8
Self-tapping and spaced thread screws
Thread-cutting or space
thread screws are not used
fro electrical connections.
Machine screws only.
thread screws are not used
fro electrical connections.
Machine screws only.
N/A
3.1.9
Termination of conductors
All conductors are reliable
secured.
secured.
Pass
10 N pull test
Considered.
Pass
3.1.10
Sleeving on wiring
N/A
page 18 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
3.2
Connection to a.c. mains supplies
Pass
3.2.1
Means of connection ........................................ : The unit is provided with an
appliance inlet.
Pass
3.2.2
Multiple supply connections
Single mains supply.
N/A
3.2.3
Permanently connected equipment
The equipment is not
permanently connected.
permanently connected.
N/A
Number of conductors, diameter (mm) of cable
and conduits .................................................... :
and conduits .................................................... :
3.2.4
Appliance inlets
The appliance inlet complies
with IEC 60320.
with IEC 60320.
Appliance inlet can be
inserted without difficulty and
so placed that, after insertion
of the connector, the
equipment is not supported by
the connector for any position
of normal use on a flat
surface.
inserted without difficulty and
so placed that, after insertion
of the connector, the
equipment is not supported by
the connector for any position
of normal use on a flat
surface.
Pass
3.2.5
Power supply cords
Not provided
N/A
Type ................................................................. :
Rated current (A), cross-sectional area (mm
2
),
AWG.................................................................:
3.2.6
Cord anchorages and strain relief
Appliance inlet is used.
N/A
Mass of equipment (kg), pull (N) ......................:
Longitudinal displacement (mm) .......................:
3.2.7
Protection against mechanical damage
No parts under this unit likely
to damage the power supply
cord.
to damage the power supply
cord.
No sharp edges.
Pass
3.2.8
Cord guards
The equipment dose not use
a non-detachable power
supply cord.
a non-detachable power
supply cord.
N/A
D (mm); test mass (g) .......................................:
Radius of curvature of cord (mm) ......................:
3.2.9
Supply wiring space
Equipment provided with an
appliance inlet.
appliance inlet.
N/A
page 19 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
Equipment with detachable
power supply cord, connected
on appliance inlet.
power supply cord, connected
on appliance inlet.
N/A
3.3.2
Connection of non-detachable power supply
cords
cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Rated current (A), cord/cable type, cross-
sectional area (mm
sectional area (mm
2
) ......................................... :
N/A
3.3.5
Rated current (A), type and nominal thread
diameter (mm)................................................... :
diameter (mm)................................................... :
N/A
3.3.6
Wiring terminals design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
Click on the first or last page to see other ABH-4 (serv.man10) service manuals if exist.