Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
3.4 
Disconnection from the a.c. mains supply 
Pass 
3.4.1 
General requirement 
The appliance inlet is 
considered to be the 
disconnect device. 
Pass 
3.4.2 
Disconnect devices 
The equipment is provided 
with an appliance coupler. 
Pass 
3.4.3 
Permanently connected equipment 
Not permanently connected 
equipment. 
N/A 
3.4.4 
Parts which remain energized 
No parts remain energized 
when the disconnect device is 
removed. 
N/A 
3.4.5 
Switches in flexible cords 
No isolating switch in the cord 
set. 
N/A 
3.4.6 
Single-phase equipment 
Disconnect device 
disconnects all poles 
simultaneously. 
Pass 
3.4.7 
Three-phase equipment 
The unit is single-phase 
equipment. 
N/A 
3.4.8 
Switches as disconnect devices 
A switch is not considered the 
disconnect device. 
N/A 
3.4.9 
Plugs as disconnect devices 
The appliance inlet is 
considered to be the 
disconnect device. 
N/A 
3.4.10 
Interconnected equipment 
No interconnection of 
hazardous voltages or energy 
levels. 
N/A 
3.4.11 
Multiple power sources 
The equipment only receives 
power from one source. 
N/A 
 
 
3.5 
Interconnection of equipment 
Pass 
3.5.1 
General requirements 
This equipment is not 
considered for connection to 
TNV. 
N/A 
3.5.2 
Types of interconnection circuits......................... :  Interconnection circuits are 
SELV CIRCUITS. 
Pass 
3.5.3 
ELV circuits as interconnection circuits  
No ELV interconnection. 
N/A 
 
page 21 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
PHYSICAL REQUIREMENTS 
Pass 
4.1 
Stability 
Pass 
 
Angle of 10
°
 
The length and width of the 
equipment remarkably 
exceed its height.
 
N/A 
 
Test: force (N) .................................................... :  Equipment is not a floor-
standing unit. 
N/A 
4.2 
Mechanical strength 
Pass 
4.2.1 
General 
See below. 
Pass 
4.2.2 
Steady force test, 10 N 
10N were applied to 
components. 
 
No energy or other hazards. 
Pass 
4.2.3 
Steady force test, 30 N 
The equipment does not have 
any internal enclosures. 
N/A 
4.2.4 
Steady force test, 250 N 
250N were applied to other 
outer enclosure. 
 
No energy or other hazards. 
Pass 
4.2.5 
Impact test 
500g steel sphere ball fall, 
from 1.3m height onto outer 
enclosure. 
 
The test was done with all 
enclosure. No safety relevant 
damaged. 
Pass 
4.2.6 
Drop test 
Unit is not hand-held, direct 
plug-in, or transportable. 
N/A 
4.2.7 
Stress relief 
Test is carried out at 84℃, 7 
hours. No risk of shrinkage or 
distortion on enclosures due 
to release of internal stresses.  
Pass 
4.2.8 
Cathode ray tubes 
The equipment does not have 
any CRT. 
N/A 
 
Picture tube separately certified......................... :        
N/A 
4.2.9 
High pressure lamps 
The equipment does not have 
any high pressure lamps. 
N/A 
4.2.10 
Wall or ceiling mounted equipment; force (N)  ... :  Not wall mounted equipment. 
N/A 
 
 
 
 
 
 
 
 
 
 
 
page 22 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
4.3 
Design and construction  
Pass 
4.3.1 
Edges and corners 
All edges and corners are 
judged to be sufficiently well 
rounded so as not to 
constitute a hazard. 
Pass 
4.3.2 
Handles and manual controls; force (N).............:        
N/A 
4.3.3 
Adjustable controls  
The equipment does not have 
a voltage selector. 
 
The equipment is auto-
ranging. 
N/A 
4.3.4 
Securing of parts 
No loosening of parts 
impairing creepage distances 
or clearances over 
supplementary or reinforced 
insulation is likely to occur. 
Pass 
4.3.5 
Connection of plugs and sockets 
The equipment does not have 
any interchangeable 
plugs/sockets. 
N/A 
4.3.6 
Direct plug-in equipment 
Not direct plug-in equipment. 
N/A 
 
Torque (Nm) .....................................................:        
 
4.3.7 
Heating elements in earthed equipment 
The equipment does not have 
any heating elements. 
N/A 
4.3.8 
Batteries 
No batteries in the equipment. 
N/A 
4.3.9 
Oil and grease 
The insulation of the internal 
wiring is not exposed to oil, 
grease, etc. 
N/A 
4.3.10 
Dust, powders, liquids and gases 
The equipment does not 
produce dust or employ 
powders, liquids or gases. 
N/A 
4.3.11 
Containers for liquids or gases 
The equipment does not 
contain liquids. 
N/A 
4.3.12 
Flammable liquids .............................................:  The equipment does not use 
any flammable liquids. 
N/A 
 
Quantity of liquid (l) ...........................................:        
N/A 
 
Flash point (
°
C).................................................:        
N/A 
4.3.13 
Radiation; type of radiation ...............................:  The equipment does not 
generate ionizing radiation or 
contain flammable liquids or 
gases. 
N/A 
 
Equipment using lasers 
      
N/A 
 
 
 
 
 
 
 
 
 
page 23 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
4.4 
Protection against hazardous moving parts 
N/A 
4.4.1 
General 
Equipment does not have any 
hazardous moving parts. 
N/A 
4.4.2 
Protection in operator access areas 
Equipment does not have any 
hazardous moving parts. 
N/A 
4.4.3 
Protection in restricted access locations  
Equipment does not have any 
hazardous moving parts. 
N/A 
4.4.4 
Protection in service access areas 
Unintentional contact with 
hazardous moving parts by 
service personnel is unlikely. 
N/A 
 
 
4.5 
Thermal requirements 
Pass 
4.5.1 
Temperature rises 
See enclosed test record 
Pass 
 
Normal load condition per Annex L.................... : 
 
N/A 
4.5.2 
Resistance to abnormal heat 
No parts at hazardous voltage 
are directly mounted on 
thermoplastic parts. 
N/A 
 
 
4.6 
Openings in enclosures 
Pass 
4.6.1 
Top and side openings 
No opening on enclosure. 
NA 
 
Dimensions (mm) ............................................. :   
 
4.6.2 
Bottoms of fire enclosures 
No opening on enclosure. 
N/A 
 
Construction of the bottom ................................ :   
 
4.6.3 
Doors or covers in fire enclosures 
The equipment does not have 
any doors or covers. 
N/A 
4.6.4 
Openings in transportable equipment 
No opening on enclosure. 
N/A 
4.6.5 
Adhesives for constructional purposes 
Adhesives not used for 
securement of internal 
barriers or screens. 
N/A 
 
Conditioning temperature/time........................... :        
 