DOWNLOAD Harman Kardon ABH-4 (serv.man10) Service Manual ↓ Size: 4.31 MB | Pages: 102 in PDF or view online for FREE

Model
ABH-4 (serv.man10)
Pages
102
Size
4.31 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
abh-4-sm10.pdf
Date

Harman Kardon ABH-4 (serv.man10) EMC - CB Certificate ▷ View online

 
page 36 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
Insulator 
Various 
Various 
V-2 minimum, 
two halves 
construction, 
overall minimum 
96.82 by 118 
mm, 0.4 mm 
thick minimum. 
Located 
between solder 
side and EMI 
shielding. 
-- 
-- 
Transformer (T1)  Salom 
Electronics Co., 
Ltd. 
SPB-0667 
Class B 
-- 
-- 
Optical Isolators 
(PH1) 
Vishay 
TCET1108 
minimum 
3000Vac, 
insulation 
thickness min. 
0.4mm 
VDE, FIMKO 
UL1577        
VDE 0884      
IEC 60950 
Alternate Optical 
Isolators (PH1) 
Vishay 
TCET1106 
minimum 
3000Vac, 
insulation 
thickness min. 
0.4mm 
VDE, FIMKO 
UL1577        
VDE 0884      
IEC 60950 
Alternate Optical 
Isolators (PH1) 
Taiwan Liton 
LTV-817C 
minimum 
3000Vac, 
insulation 
thickness min. 
0.4mm 
VDE, FIMKO 
UL1577        
VDE 0884      
IEC 60950 
Alternate Optical 
Isolators (PH1) 
Toshiba 
TLP621 
minimum 
3000Vac, 
insulation 
thickness min. 
0.4mm 
VDE, FIMKO 
UL1577        
VDE 0884      
IEC 60950 
Diode (D201) 
Various 
Various 
Minimum 100V, 
20A (SELV 
limiting 
component) 
-- 
-- 
Diode (D202) 
Various 
Various 
Minimum 200V, 
20A (SELV 
limiting 
component) 
-- 
-- 
1) an asterisk indicates a mark which assures the agreed level of surveillance 
 
page 37 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
1.6.2 
TABLE: electrical data (in normal conditions) 
Pass 
fuse # 
I rated (A) 
U (V) 
P (W) 
I (mA) 
I fuse (mA)  condition/status 
      
 
 
 
 
  See enclosed test record 
 
 
 
 
 
   
supplementary information: 
      
 
 
2.10.3 and 
2.10.4 
TABLE: clearance and creepage distance measurements 
Pass 
clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s. 
(V) 
required cl 
(mm) 
cl (mm) 
required 
dcr (mm) 
dcr 
(mm) 
Primary trace to earth trace 
<420 
<240 
2.9 
2.5 
2.9 
Trace under Transformer (T1) 
496 
282 
4.4 
6.6 
6.6 
Trace under CY2 
<420 
<240 
6.2 
6.2 
Trace under PH1 
<420 
<240 
9.8 
9.8 
Primary  components to EMI 
shielding (secondary)  
<420 
<240 
>4 
>5 
 
 
 
2.10.5 
TABLE: distance through insulation measurements 
Pass 
distance through insulation di at/of: 
U r.m.s. 
(V) 
test voltage 
(V) 
required di 
(mm) 
di 
(mm) 
Optical Isolators 
282 
AC 3000 
0.4 
Approved 
component 
Insulator 
282  
AC 3000 
0.4 
0.4 
supplementary information: 
      
 
page 38 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
4.5 
TABLE: temperature rise measurements 
Pass 
 
test voltage (V)  ...................................................:  See enclosed test record. 
 
 
t1 (
°
C
)  .................................................................:  -- 
 
 
t2 (
°
C
)  .................................................................:  -- 
 
temperature rise dT of part/at: 
dT (K) 
required dT (K) 
See enclosed test record
 
 
 
 
 
 
temperature rise dT of winding: 
R
1
 (
R
2
 (
dT (K) 
required dT 
(K) 
insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
      
 
 
4.5.2 
TABLE: ball pressure test of thermoplastics 
N/A 
 
allowed impression diameter (mm)  ......................:        
 
part 
test temperature (
°
C
)  impression diameter 
(mm) 
      
 
 
 
 
 
supplementary information: 
      
 
 
5.2 
TABLE: electric strength tests and impulse tests 
Pass 
test voltage applied between: 
test voltage (V) 
breakdown 
Yes / No 
See enclosed test record
 
 
 
 
 
 
supplementary information: 
      
 
page 39 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
5.3 
TABLE: fault condition tests 
Pass 
 
ambient temperature (
°
C)  ....................................:  25°C 
 
 
model/type of power supply  .................................:  See Table 1.5.1 
 
 
manufacturer of power supply  .............................:  ditto. 
 
 
rated markings of power supply  ...........................:  ditto. 
 
component 
No. 
fault 
test voltage 
(V) 
test time 
fuse 
No. 
fuse current 
(A) 
result 
      
 
 
 
 
 
See enclosed test record
 
 
 
 
 
 
 
 
supplementary information: 
      
 
 
A.6.5 
TABLE: flammability test for classifying materials V-0, V-1 or V-2 
N/A 
sample 
No. / ref. 
afterflame time (s) t
or t
2
 
afterflame + afterglow (s) after 2nd flame 
application t
+  t
3
  
1/A 
 
 
2/A 
 
 
3/A 
 
 
4/A 
 
 
5/A 
 
 
6/B 
 
 
7/B 
 
 
8/B 
 
 
9/B 
 
 
10/B 
 
 
 
 
A.6.6 
TABLE: flammability re-test for classifying materials V-0, V-1 or V-2 
N/A 
sample 
No. 
afterflame time (s) t
or t
2
 
afterflame + afterglow (s) after 2nd flame 
application t
+  t
3
  
11 
 
 
12 
 
 
13 
 
 
14 
 
 
15 
 
 
Page of 102
Display