Harman Kardon ABH-4 (serv.man10) EMC - CB Certificate ▷ View online
page 4 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
1
GENERAL
Pass
1.5
Components
Pass
1.5.1
Comply with IEC 950 or relevant component
standard
standard
(see appended table)
Pass
1.5.2
Evaluation and testing components
Certified components are used
in accordance with their
ratings, certifications and they
comply with applicable parts of
this Standard.
in accordance with their
ratings, certifications and they
comply with applicable parts of
this Standard.
Pass
Dimensions (mm) of mains plug for direct plug-in .: Not direct plug-in equipment.
N/A
Torque and pull test of mains plug for direct
plug-in; torque (Nm); pull (N)
plug-in; torque (Nm); pull (N)
N/A
1.5.3
Transformers
Transformer used is suitable for
their intended application and
comply with the relevant
requirements of the standard
and particularly those of Annex
C.
their intended application and
comply with the relevant
requirements of the standard
and particularly those of Annex
C.
Pass
1.5.4
Flammability class of high voltage components
(component; manufacturer; flammability)
(component; manufacturer; flammability)
No high-voltage components.
N/A
1.5.5
Interconnecting cables
No interconnecting cables
provided as part of the
equipment.
provided as part of the
equipment.
Pass
1.5.6
Mains capacitors
Between lines: X2 type, PCB
location X1 and X2, sub-class
capacitors according to IEC
60384-14:1993 with 21 days
damp heat test.
location X1 and X2, sub-class
capacitors according to IEC
60384-14:1993 with 21 days
damp heat test.
Pass
page 5 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
1.6
Power interface
Pass
1.6.1
Steady state input current
(see attached test record)
Pass
Current deviation during normal operating cycle
The current deviation during
the normal operating cycle did
not exceed 10 %.
the normal operating cycle did
not exceed 10 %.
Pass
1.6.2
Voltage limit of hand-held equipment
The unit is not a hand-held
equipment.
equipment.
N/A
1.6.3
Neutral conductor insulated from earth and body
The neutral is not identified in
the equipment. Basic insulation
for rated voltage between
earthed parts and primary
phases.
the equipment. Basic insulation
for rated voltage between
earthed parts and primary
phases.
Pass
1.6.4
Components in equipment intended for IT power
system
system
N/A
1.6.5
Mains supply tolerance (V):
120-240 V ac
Pass
page 6 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
1.7
Marking and instructions
Pass
1.7.1
Rated voltage (V) ................................................: Input rating: 120-240V ac,
Output rating: 24V dc, 4A
Pass
Symbol of nature of supply for d.c. .......................:
Mains from AC source
N/A
Rated frequency (Hz) ..........................................: 50/60 Hz
N/A
Rated current (A) ................................................: 3 A.
Pass
Manufacturer ......................................................: SALOM ELECTRIC
(THAILAND) CO LTD
Pass
Trademark ..........................................................:
or
Pass
Type/model ........................................................: PS6 or SSB-0124
Pass
Symbol of Class II ...............................................: The equipment is regarded as
Class I
N/A
Certification marks ..............................................: CE, UL
Pass
1.7.2
Safety instructions
Operating/safety instructions
made available to the user.
made available to the user.
Pass
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4
Marking for voltage setting/frequency setting ........: Equipment is full ranging.
N/A
1.7.5
Marking at power outlets .....................................: No standard power outlets are
provided.
N/A
1.7.6
Marking at fuseholders ........................................: T3.15A, 250V
Pass
1.7.7
Wiring terminals
See below.
Pass
1.7.7.1
Protective earthing terminals
Appliance inlet is provided.
N/A
1.7.7.2
Terminal for external primary power supply
conductors
conductors
N/A
1.7.8.1
Identification, location and marking ................... :
N/A
1.7.8.2
Colours ........................................................... :
N/A
1.7.8.3
Symbols according to IEC 60417 ...................... :
N/A
1.7.8.4
Markings using figures .................................... : Figures are not used for
indicating different positions of
controls.
controls.
N/A
1.7.9
Isolation of multiple power sources ................... : There is only one connection
to hazardous voltages.
N/A
1.7.10
IT power system
Not intended for use on IT
power systems.
power systems.
N/A
page 7 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
1.7.11
Thermostats and other regulating devices
No thermostats or similar
regulating devices.
regulating devices.
N/A
1.7.12
Language ......................................................... : Reviewed only English
markings/instructions.
May be provided in other
languages when the
equipment will be applied for
other national certificated.
languages when the
equipment will be applied for
other national certificated.
1.7.13
Durability
All markings provided on UL
Recognized Component
labels suitable for surface they
are applied upon.
Recognized Component
labels suitable for surface they
are applied upon.
Pass
1.7.14
Removable parts
No marking is located on (a)
removable part(s).
removable part(s).
Pass
1.7.15
Replaceable batteries
The lithium battery is not
located in an Operator Access
Area.
located in an Operator Access
Area.
N/A
Language.......................................................... :
1.7.16
Operator access with a tool ............................... : No operator access areas
require the use of a tool.
Pass
1.7.17
Equipment for restricted access locations.......... : Equipment not intended for
installation in a RESTRICTED
ACCESS LOCATION.
ACCESS LOCATION.
N/A
Click on the first or last page to see other ABH-4 (serv.man10) service manuals if exist.