page 4 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
GENERAL 
Pass 
 
 
1.5 
Components 
Pass 
1.5.1 
Comply with IEC  950 or relevant component 
standard 
(see appended table) 
Pass 
1.5.2 
Evaluation and testing components 
Certified components are used 
in accordance with their 
ratings, certifications and they 
comply with applicable parts of 
this Standard. 
Pass 
 
Dimensions (mm) of mains plug for direct plug-in  .:  Not direct plug-in equipment. 
N/A 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N) 
      
N/A 
1.5.3 
Transformers 
Transformer used is suitable for 
their intended application and 
comply with the relevant 
requirements of the standard 
and particularly those of Annex 
C.
 
Pass 
1.5.4 
Flammability class of high voltage components 
(component; manufacturer; flammability) 
No high-voltage components. 
N/A 
1.5.5 
Interconnecting cables 
No interconnecting cables 
provided as part of the 
equipment. 
Pass 
1.5.6 
Mains capacitors 
Between lines: X2 type, PCB 
location X1 and X2, sub-class 
capacitors according to IEC 
60384-14:1993 with 21 days 
damp heat test. 
 
Pass 
 
page 5 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
1.6 
Power interface 
Pass 
1.6.1 
Steady state input current 
(see attached test record) 
Pass 
 
Current deviation during normal operating cycle 
The current deviation during 
the normal operating cycle did 
not exceed 10 %. 
Pass 
1.6.2 
Voltage limit of hand-held equipment 
The unit is not a hand-held 
equipment. 
N/A 
1.6.3 
Neutral conductor insulated from earth and body 
The neutral is not identified in 
the equipment. Basic insulation 
for rated voltage between 
earthed parts and primary 
phases.
 
Pass 
1.6.4 
Components in equipment intended for IT power 
system 
 
N/A 
1.6.5 
Mains supply tolerance (V): 
120-240 V ac 
Pass 
 
page 6 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
 
1.7 
Marking and instructions 
Pass 
1.7.1 
Rated voltage (V)  ................................................:  Input rating: 120-240V ac,  
Output rating: 24V dc, 4A 
Pass 
 
Symbol of nature of supply for d.c.  .......................: 
Mains from AC source
 
N/A 
 
Rated frequency (Hz)  ..........................................:  50/60 Hz 
N/A 
 
Rated current (A)  ................................................:  3 A. 
Pass 
 
Manufacturer  ......................................................:  SALOM ELECTRIC 
(THAILAND) CO LTD 
Pass 
 
Trademark  ..........................................................: 
 
or 
 
Pass 
 
Type/model  ........................................................:  PS6 or SSB-0124 
Pass 
 
Symbol of Class  II  ...............................................:  The equipment is regarded as 
Class I 
N/A 
 
Certification marks  ..............................................:  CE, UL 
Pass 
1.7.2 
Safety instructions 
Operating/safety instructions 
made available to the user. 
Pass 
1.7.3 
Short duty cycles 
The equipment is intended for 
continuous operation. 
N/A 
1.7.4 
Marking for voltage setting/frequency setting ........:  Equipment is full ranging. 
N/A 
1.7.5 
Marking at power outlets  .....................................:  No standard power outlets are 
provided. 
 
N/A 
1.7.6 
Marking at fuseholders  ........................................:  T3.15A, 250V 
Pass 
1.7.7 
Wiring terminals 
See below. 
Pass 
1.7.7.1 
Protective earthing terminals 
Appliance inlet is provided. 
N/A 
1.7.7.2 
Terminal for external primary power supply 
conductors 
 
N/A 
1.7.8.1 
Identification, location and marking  ................... :   
N/A 
1.7.8.2 
Colours   ........................................................... :   
N/A 
1.7.8.3 
Symbols according to IEC 60417 ...................... : 
 
N/A 
1.7.8.4 
Markings using figures   .................................... :  Figures are not used for 
indicating different positions of 
controls. 
N/A 
1.7.9 
Isolation of multiple power sources  ................... :  There is only one connection 
to hazardous voltages. 
N/A 
1.7.10 
IT power system 
Not intended for use on IT 
power systems. 
N/A 
 
page 7 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
1.7.11 
Thermostats and other regulating devices  
No thermostats or similar 
regulating devices. 
N/A 
1.7.12 
Language ......................................................... :  Reviewed only English 
markings/instructions. 
 
May be provided in other 
languages when the 
equipment will be applied for 
other national certificated. 
 
1.7.13 
Durability 
All markings provided on UL 
Recognized Component 
labels suitable for surface they 
are applied upon. 
Pass 
1.7.14 
Removable parts 
No marking is located on (a) 
removable part(s). 
Pass 
1.7.15 
Replaceable batteries 
The lithium battery is not 
located in an Operator Access 
Area. 
N/A 
 
Language.......................................................... :        
 
1.7.16 
Operator access with a tool ............................... :  No operator access areas 
require the use of a tool. 
Pass 
1.7.17 
Equipment for restricted access locations.......... :  Equipment not intended for 
installation in a RESTRICTED 
ACCESS LOCATION. 
N/A 