Sony HDR-SR1 / HDR-SR1E (serv.man4) Service Manual ▷ View online
6-7
HDR-SR1/SR1E_ADJ
3.
Function of Each Button on Main Menu Screen
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-9 will appear. On this screen, select each adjust-
ment section.
screen in Fig. 6-1-9 will appear. On this screen, select each adjust-
ment section.
Fig. 6-1-9
1
[Connecting the Equipment] button
A connection diagram of the equipment is displayed.
A connection diagram of the equipment is displayed.
2
[CONNECT] button
The mode of Camcorder is switched to the Adjustment Mode.
When the Adjustment Mode has switched normally, the op-
eration of the buttons 4 - 0 is enabled.
The mode of Camcorder is switched to the Adjustment Mode.
When the Adjustment Mode has switched normally, the op-
eration of the buttons 4 - 0 is enabled.
3
[END] button
The mode of Camcorder is switched to the normal mode.
When the normal mode has switched correctly, the Automatic
Adjustment Program is finished.
The mode of Camcorder is switched to the normal mode.
When the normal mode has switched correctly, the Automatic
Adjustment Program is finished.
4
[DESTINATION DATA WRITE] button
The “DESTINATION DATA WRITE” screen appears.
The “DESTINATION DATA WRITE” screen appears.
5
[VIDEO SYSTEM ADJUSTMENT] button
The “VIDEO SYSTEM ADJUSTMENT” screen appears.
The “VIDEO SYSTEM ADJUSTMENT” screen appears.
6
[CAMERA SYSTEM ADJUSTMENT] button
The “CAMERA SYSTEM ADJUSTMENT” screen appears.
The “CAMERA SYSTEM ADJUSTMENT” screen appears.
7
[LCD/EVF SYSTEM ADJUSTMENT] button
The “LCD/EVF SYSTEM ADJUSTMENT” screen appears.
The “LCD/EVF SYSTEM ADJUSTMENT” screen appears.
8
[AUDIO SYSTEM ADJUSTMENT] button
The “AUDIO SYSTEM ADJUSTMENT” screen appears.
The “AUDIO SYSTEM ADJUSTMENT” screen appears.
9
[SERVICE MODE] button
The “SERVICE MODE” screen appears.
The “SERVICE MODE” screen appears.
0
[DATA BACKUP] button
The “DATA BACKUP” screen appears.
The “DATA BACKUP” screen appears.
qa
This part indicates the version of Automatic Adjustment Pro-
gram.
gram.
3
5
4
7
8
6
2
1
9
0
qa
1-2.
ADJUSTMENT PROGRAM
The HDR-SR1/SR1E are adjusted by the Automatic Adjustment
Program. The Automatic Adjustment Program enters automatically
via the SeusEX the adjustment operations that were formerly en-
tered manually by the adjustment remote commander (some items
may be adjusted by manual operation on the operation screen of
the SeusEX).
Program. The Automatic Adjustment Program enters automatically
via the SeusEX the adjustment operations that were formerly en-
tered manually by the adjustment remote commander (some items
may be adjusted by manual operation on the operation screen of
the SeusEX).
1.
Precautions When Using Automatic Adjustment Pro-
gram
gram
1) The Automatic Adjustment Program writes the adjustment re-
sults such as EVR data to the set through two-way communi-
cation with the camcorder via the SeusEX. Accordingly, the
Automatic Adjustment Program must be used in the
environment where the SeusEX operates.
cation with the camcorder via the SeusEX. Accordingly, the
Automatic Adjustment Program must be used in the
environment where the SeusEX operates.
2) The Automatic Adjustment Program cannot be used when the
SEUS or the SeusCam is running. Exit the SEUS or the
SeusCam before using the Automatic Adjustment Program.
SeusCam before using the Automatic Adjustment Program.
3) The SeusEX must be already started on the PC when using the
Automatic Adjustment Program. With the SeusEX not started,
some adjustment items will take time in adjustment.
some adjustment items will take time in adjustment.
4) The program run time may vary depending on the environ-
ment of the personal computer used.
2.
Start of Automatic Adjustment Program
Double-click the application file (HDR-SR1 Series Auto-Adj
Ver_1.3r03.exe), and the Automatic Adjustment Program will start.
Ver_1.3r03.exe), and the Automatic Adjustment Program will start.
Ver. 1.3 2008.04
6-8
HDR-SR1/SR1E_ADJ
4.
Setting of Adjustment Mode
Before performing the adjustment, “Setting of Adjustment Mode”
is required.
is required.
[Setting method]
1) Connect the Camcorder to the PC with a USB cable, and turn
1) Connect the Camcorder to the PC with a USB cable, and turn
on the power switch.
2) The USB SELECT menu will appear on the LCD screen of
the Camcorder, and then select “COMPUTER” to establish
the connection.
the connection.
3) Start the Automatic Adjustment Program, and click the [Con-
nect] button on the Main Menu screen.
4) When the following message is displayed, turn off and on again
the power switch of the Camcorder.
Note:
Turing off and on the power switch causes the
Camcorder to be switched to the Adjustment Mode.
After the Camcorder restarted, click the [OK] button in
the message window.
Camcorder to be switched to the Adjustment Mode.
After the Camcorder restarted, click the [OK] button in
the message window.
5) Upon successful completion of the settings in the Adjustment
Mode, the operation of each button on the Main Menu screen
is enabled.
is enabled.
5.
Release of Adjustment Mode
To finish the adjustment, be sure to perform “Release of Adjust-
ment Mode”.
ment Mode”.
[Releasing method]
1) Click the [END] button on the Main Menu screen.
2) When the following message is displayed, releasing of adjust-
1) Click the [END] button on the Main Menu screen.
2) When the following message is displayed, releasing of adjust-
ment mode has completed. Click the [OK] button in the mes-
sage window to exit the Automatic Adjustment Program.
sage window to exit the Automatic Adjustment Program.
Note:
The Camcorder switches to the normal mode by turn-
ing off and on the power switch. After the adjustment
finished, turn off and on again the power switch of the
Camcorder to confirm that the USB SELECT menu is
displayed.
ing off and on the power switch. After the adjustment
finished, turn off and on again the power switch of the
Camcorder to confirm that the USB SELECT menu is
displayed.
6-9
HDR-SR1/SR1E_ADJ
1-3.
HDD SYSTEM ADJUSTMENTS
When the HDD is replaced, the following VBScript files are used.
The Automatic Adjustment Program (HDR-SR1 Series Auto-Adj
Ver 1.[]r[][].exe) is not used.
• CheckHDDError.vbe
The Automatic Adjustment Program (HDR-SR1 Series Auto-Adj
Ver 1.[]r[][].exe) is not used.
• CheckHDDError.vbe
• SetFactoryCheckDefault.vbe
• SetFactoryCheckFull.vbe
• ExecAfterFactoryCheck.vbe
For the VBScript files ([][][][][][][].vbe), the program is executed
by double-clicking the file.
by double-clicking the file.
Note:
The VBScript files can only be used on the PC in which the
SeusEX is installed.
SeusEX is installed.
6-10
HDR-SR1/SR1E_ADJ
Message is checked.
When message is
“No Error”
“No Error”
When message is
“Error Detected”
“Error Detected”
Is replacement HDD new one?
No
Reused HDD
Reused HDD
Yes
New HDD
New HDD
Connect the camcorder to the PC
with a USB cable, and turn on the
power switch.
with a USB cable, and turn on the
power switch.
Turn off the power of camcorder.
Turn off the power and turn on again.
Turning on the power of camcorder
will start automatic Factory Check.
Wait until Factory Check completed. (Note)
[EST. PROCESS TIME]
Default: 6 min.
Full:
Full:
1 hour 58 min.
Replace the HDD.
The USB SELECT menu will appear
on the LCD screen of the camcorder,
and the select “COMPUTER” to
establish the connection.
on the LCD screen of the camcorder,
and the select “COMPUTER” to
establish the connection.
“Manegement file damaged.
Create new file?” will appear
on the LCD screen of the camcorder,
and the select [YES].
Create new file?” will appear
on the LCD screen of the camcorder,
and the select [YES].
Execte the “CheckHDDError.vbe”.
(Double-click the file.)
(Double-click the file.)
Execte the
“SetFactoryCheckDefault.vbe”.
(Double-click the file.)
“SetFactoryCheckDefault.vbe”.
(Double-click the file.)
Wait until “JOB Success”
message is displayed.
(several seconds)
message is displayed.
(several seconds)
Wait until “JOB Success”
message is displayed.
(several seconds)
message is displayed.
(several seconds)
Wait until “JOB Success”
message is displayed.
(several seconds)
message is displayed.
(several seconds)
Execte the
“SetFactoryCheckFull.vbe”.
(Double-click the file.)
“SetFactoryCheckFull.vbe”.
(Double-click the file.)
Execte the
“ExecAfterFactoryCheck.vbe”.
(Double-click the file.)
“ExecAfterFactoryCheck.vbe”.
(Double-click the file.)
Replacing the HDD is unneccessary.
Start
End
1. HDD Replacing Procedure
Note:
During the execution of Factory Check, the LCD screen of
the camcorder becomes gray.
When the Factory Check finished, the LCD screen changes
as follows:
the camcorder becomes gray.
When the Factory Check finished, the LCD screen changes
as follows:
When Factory Check is OK: Camera image display
When Factory Check is NG: Blue display
When Factory Check is NG: Blue display
Click on the first or last page to see other HDR-SR1 / HDR-SR1E (serv.man4) service manuals if exist.