Model
TX-21PM10TQ
Pages
29
Size
35.14 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
tx-21pm10tq.pdf
Date

Panasonic TX-21PM10TQ Service Manual ▷ View online

Power Source :
AC AUTO 110-240V, 50/60 Hz
Power Consumption :
74W
Aerial Impedance :
75
unbalanced
Coaxial type
Receiving System :
17 Systems
Receiving Channels :
VHF
2-12 (PAL/SECAM B, K1)
0-12 (PAL B AUST.)
1-9 (PAL B N.Z.)
1-12 (PAL/SECAM D)
1-12 (NTSC M JAPAN)
2-13 (NTSC M U.S.A.)
UHF
21-69 (PAL G, H, I/SECAM G, K, K1)
28-69 (PAL B AUST.)
13-57 (PAL D, K)
13-62 (NTSC M JAPAN)
14-69 (NTSC M U.S.A.)
CATV
S1-S41 (OSCAR)
1-125 (U.S.A. CATV)
C13-C41 (JAPAN)
S21-S41 (HYPER)
Z1-Z37 (CHINA)
TX-21PM10TQ
MX-7Z Chassis
Intermediate Frequency :
Video
38.0 MHz
Sound
31.5 MHz (D, K, K1) / 32.5 MHz (B, G)
32.0 MHz (I) / 32.5 MHz (M)
Colour
33.57 MHz (PAL)
33.6 MHz (SECAM)
32.5 MHz (B, G)
33.75 MHz (SECAM)
34.42 MHz (NTSC)
Video / Audio Terminals :
FAV In
Video In 1 Vp-p 75
Audio In Approx. 400mVrms
RAV In
Video In 1 Vp-p 75
Audio In Approx. 400mVrms
Monitor Out
Video Out 1 Vp-p 75
Audio Out Approx. 400mVrms
High Voltage :
28.1kV (±1.5)
at zero beam current
Picture Tube :
A51LSK955X-A
51cm (21 inches)
Measured diagony,
90° deflection
Audio Output :
3.5W
Speaker :
8
Colour Television
Specifications
ORDER NO. MTV0207184C3-CIS
Dimensions :
Height : 470.0 mm
Width : 508.0 mm
Depth : 475.0 mm
 1 
Safety Precautions 
3
 1.1. 
General Guide Lines 
3
 1.2. 
Leakage Current Cold Check 
3
 1.3. 
Leakage Current Hot Check (Fig. 1) 
3
 1.4. 
X-Radiation 
3
 1.5. 
MX-7Z Chassis Block Diagram 
4
 2 
Service Hints 
5
 2.1. 
Service Position for E-Board 
5
 2.2. 
Factory Mode Adjustment 
5
 2.3. 
Adjustment for White Balance 
6
 2.4. 
Adjustment for CRT CUT OFF 
6
 2.5. 
Adjustment Procedure 
7
Mass :
23.0 kg (Net Wt.)
Specifications are subject to change without notice.
Mass and dimensions shown are approximate.
 2.6. 
PAL Colour 
8
 2.7. 
Adjustment 
8
 3 
Conductor Views (TNP4G175AR) 
11
 4 
Schematic Diagram 
12
 4.1. 
L BOARD (TNP4G176AG) 
14
 4.2. 
EW BOARD (TNP4G186AA) 
16
 4.3. 
Z5 BOARD (TNP4G185AB) 
18
 4.4. 
A BOARD (TNP4G175AR) 
20
 5 
Parts Location 
23
 6 
Replacement Parts List 
24
 6.1. 
Replacement Parts List 
25
CONTENTS
 Page 
Page
2
TX-21PM10TQ
1 Safety Precautions
1.1. General Guide Lines
 1. It is advisable to insert an isolation transformer in the AC supply before servicing this hot chassis.
 2. When servicing, observe the original lead dress, especially the lead dress in the high voltage circuits. If a short circuit is found,
replace all parts which have been overheated or damaged by the short circuit.
 3. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers, shields and isolation R-C
combinations, are properly installed.
 4. When the receiver is not to be used for a long period of time, unplug the power cord from the AC cord outlet.
 5. Potential, as high as 29.6kV is present when this receiver is in operation. Operation of the receiver without the rear cover
involves the danger of a shock hazard from the receiver power supply. Servicing should not be attempted by anyone who is not
thoroughly familiar with the precautions necessary when working on high voltage equipment. Always discharge the anode of the
picture tube to the receiver chassis before handling the tube. After servicing make the following leakage current checks to
prevent the customer from being exposed to shock hazards.
1.2. Leakage Current Cold Check
 1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
 2. Turn on the receiver’s power switch.
Measure the resistance value, with an ohmmeter, between the jumper AC plug and each exposed metallic cabinet part on the
receiver, such as screw heads, aerials, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 4 M
and 20 M
. When the exposed metal does not have a return path to the chassis,
the reading must be infinite.
1.3. Leakage Current Hot Check (Fig. 1)
 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
 2. Check a 2 k
non-inductive resistor and an AC/DC current meter, in series with each exposed metallic part on the receiver in
turn and an earth such as a water pipe.
The current from any point should not exceed 0.7 mA peak AC or 2 mA DC. In the case of a measurement being outside of
these limits specified, there is a possibility of a shock hazard and the receiver should be repaired and rechecked before it is
returned to the customer.
Fig. 1
1.4. X-Radiation
Warning:
The potential sources of X-Radiation in TV set are the EHT section and the picture tube. When using a picture tube test jig for
service, ensure that jig is capable of handling 29.6kV without causing X-Radiation.
Note: It is important to use an accurate periodically calibrated high voltage meter.
 1. Set the brightness to minimum.
 2. Use the remocon to get into Service Mode.
 3. Measure the EHT. The meter reading should indicate 28.1 (±1.5)kV. If the meter indication is out of tolerance, immediate
service and correction is required to prevent the possibility of premature component failure.
 4. To prevent the possibility X-Radiation, it is essential to use the specified picture tube, if service replacement becomes
necessary.
3
TX-21PM10TQ
1.5. MX-7Z Chassis Block Diagram
4
TX-21PM10TQ
Page of 29
Display

Panasonic TX-21PM10TQ Service Manual ▷ Download

  • DOWNLOAD Panasonic TX-21PM10TQ Service Manual ↓ Size: 35.14 MB | Pages: 29 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic TX-21PM10TQ in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic TX-21PM10TQ TV. Information contained in Panasonic TX-21PM10TQ Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.