Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc1-hdr-hc1e-hdr-hc1ek-hdr-hc1k-sm4.pdf
Date

Sony HDR-HC1 / HDR-HC1E / HDR-HC1EK / HDR-HC1K (serv.man4) Service Manual ▷ View online

6-47
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
21. PCGM Standard Data Input 
RadarW
RadarW
RadarW
Adjust the matrix coefficient for compensating the variation in
spectral sensitivity, to carry out presumed detection of the light
source for AWB.
Adjustment Page
6F
Adjustment Address
2E to 3F
Note 1: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: 6F, address: 2E to 3F.
Note 2: Press the PAUSE button of the adjustment remote com-
mander each time to set data.
Address
Data
NTSC PAL
2E
1F
1F
2F
64
64
30
FF
FF
31
3E
3E
32
00
00
33
23
23
34
01
01
35
CF
CF
36
1E
1E
37
1B
1B
38
00
00
39
F9
F9
3A
00
00
3B
84
84
3C
FF
FF
3D
A4
A4
3E
1F
1F
3F
8B
8B
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
6-48
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
22. Auto White Balance Check 
RadarW
RadarW
RadarW
Subject
Clear chart (All white frame)
Filter
ND filter 1.0, 0.4 and 0.1
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Specified Value
8000 to 8BC0
Note 1: Perform “Auto White Balance Adjustment” and “Color
Reproduction  Adjustment” before this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”
2
0
10
06
3
9
06
84
Press PAUSE button.
(69)
4
0
10
00
5
6
4D
40
6
6
CA
Set the bit value of bit0 is
“1”. (Note 4)
7
6
C9
10
Outdoor white balance check
8
6
01
4F
Press PAUSE button.
9
0
03
33
10
1
Check that bit15 of the
display data (Note 3) is “1”.
(Note 5)
11
6
01
00
Press PAUSE button.
Indoor white balance check
12
6
01
0F
Press PAUSE button.
13
1
Check that bit15 of the
display data (Note 3) is “1”.
(Note 5)
14
6
01
00
Press PAUSE button.
InOut data check
15
Place the ND filter 1.5 (1.0 +
0.4 + 0.1) on the lens.
16
6
C9
11
17
6
30
07
18
0
03
06
19
1
Check that the displayed data
(Note 3) satisfied the
specified value.
20
6
30
00
21
6
C9
00
22
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Note 4: For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
Note 5: When bit15 of the display data is “1”, the display data is
“8000” to “FFFF”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
4D
00
3
6
CA
Set the bit value of bit0 is
“0”.
4
0
10
06
5
9
06
14
Press PAUSE button.
(69)
6
0
10
00
6-49
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
24. MAX GAIN Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects
in low illuminance will not be produced (dark).
Subject
Clear chart (Center frame)
Adjustment Page
6F
Adjustment Address
2C
Note 1: Perform “Flange Back Adjustment” before this adjust-
ment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) ZOOM .................................................................... WIDE end
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
7) REC FORMAT (Menu setting) ............................ HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Center Frame”. If not,
perform “23. Picture Frame
Setting (Center Frame)”
2
0
01
01
3
6
4D
40
4
6
C9
10
5
6
D0
Set the following data
2C: NTSC model
1C: PAL model
6
6
D1
00
7
6
01
6F
Press PAUSE button. (Note 4)
8
6
02
Check the data changes to
“01”.
Note 4: The adjustment data will be automatically input to page:
6F, address: 2C.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
4D
00
2
6
C9
00
3
6
01
00
Press PAUSE button.
4
0
01
00
23. Picture Frame Setting (Center frame)
Subject
Clear chart (Center frame)
(1 m (PTB-450) or 40 cm (PTB-
1450)  from the front of lens)
Measurement Point
Video terminal of A/V jack (75 
terminated)
Measuring Instrument
Monitor TV
Specified Value
A clear chart must be shot in larger
size than nine grids in the center of
frame shown on the screen.
(Fig. 6-1-18)
Note: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) ZOOM .................................................................... WIDE end
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu Setting) ......................................... MANUAL
Setting method:
Order Page Address Data
Procedure
1
Shoot a clear chart in the
center of screen with the
zoom at WIDE end.
2
0
01
01
3
0
10
06
4
B
05
91
Press PAUSE button.
(6B)
5
Check that a clear chart is
shot in larger size than nine
grids in the center of frame
shown on the screen.
6
B
05
00
Press PAUSE button.
(6B)
7
0
10
00
8
0
01
00
9
In the following adjustment,
if the “Center frame” is used,
adjust the clear chart to this
position.
Fig.6-1-18
A clear chart must be shot in larger size 
than central nine grids. 
6-50
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
25. White Defect Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Defect white defective pixels of CMOS image sensor.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value
Data of page: 6 address: D3 is “00”
Note 1: Perform “Auto White Balance Adjustment” before this
adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
0D
Check the data is “04”.
3
0
10
06
4
B
41
10
Press PAUSE button.
(6B)
5
0
10
00
6
6
D0
06
7
6
01
21
Press PAUSE button.
8
6
02
Check the data changes to
“01”.
9
6
D3
Check the data is “00”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
10
06
3
B
41
10
Press PAUSE button.
(6B)
4
0
10
00
5
0
01
00
26. White Defect Adjustment (FD white point)
      
RadarW
RadarW
RadarW
RadarW
RadarW
Defect white defective pixels (FD white point) of CMOS image
sensor.
Subject
Not required
Note 1: Perform “White Defect Adjustment” before this adjust-
ment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
0D
Check the data is “04”.
3
0
10
06
4
B
41
02
Press PAUSE button.
(6B)
5
0
10
00
6
6
D0
0C
7
6
01
21
Press PAUSE button.
8
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
10
06
3
B
41
10
Press PAUSE button.
(6B)
4
0
10
00
5
0
01
00
Page of 91